5-74    Installing the Operating System with Express Setup 

(This page is intentionally left blank.) 

 

Содержание NovaScale R440 E2

Страница 1: ...NovaScale R440 E2 User s Guide NOVASCALE REFERENCE 86 A1 46FB 00...

Страница 2: ......

Страница 3: ...NOVASCALE NovaScale R440 E2 User s Guide Hardware April 2009 BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 46FB 00...

Страница 4: ...ad quation de configurations et d applications sp cifiques doit tre d termin e par ledit client et ne rel ve pas de la responsabilit de Bull Marques commerciales NEC ESMPRO NEC DianaScope NEC MWA et E...

Страница 5: ...uding burns or property damage if the instruction is ignored Precautions and notices against hazards are presented with one of the following three symbols The individual symbols are defined as follows...

Страница 6: ...n electric shock or fire may be caused Keep water or liquid away from the server Otherwise an electric shock or a fire may be caused Do not touch the server components with wet hand Otherwise an elect...

Страница 7: ...roduct may cause radio interference in which case the user may be required to take adequate measures EN55022 BSMI Statement Notes 1 No part of this manual may be reproduced in any form without the pri...

Страница 8: ...mplement a computer for the next generation With its potential capabilities the server may be used as a workstation PC that configures a client server system and provides high speed processing and sup...

Страница 9: ...our system Chapter 4 Configuring Your Server tells you how to configure the system and provides instructions for running the BIOS SETUP Utility and the RAID Configuration utility which is used to conf...

Страница 10: ...l Microsoft Windows Server 2003 without using Express Setup Using the Express Setup tool is recommended for installing Windows Server 2003 See Chapter 5 for details Appendix G Using a Client Computer...

Страница 11: ...ront View with Front Bezel Closed 2 4 Front View with Front Bezel Removed 2 5 Rear View 2 6 Internal View 2 8 Mother Board 2 10 Status Indicators 2 11 POWER LED 2 11 STATUS LED 2 11 DISK ACCESS LED 2...

Страница 12: ...D Controller 2 5 inch Disk Model 4 46 Before Using WebBIOS 4 51 Using WebBIOS 4 54 Configuring a Virtual Drive 4 69 Operating Various Features 4 85 Locate 4 96 Slow Initialize 4 97 WebBIOS and the Uni...

Страница 13: ...leaning the Server 7 3 Cleaning the Interior 7 4 Cleaning the Keyboard Mouse 7 5 Cleaning Disc 7 6 System Diagnostics 7 7 Test Items 7 7 Startup and Exit of System Diagnostics 7 8 Relocating Storing T...

Страница 14: ...19 Installation 9 19 Replacing a Failing Power Supply Unit 9 22 Top Cover 9 23 Removal 9 23 Installation 9 23 DIMM 9 24 Installation Order 9 25 Memory Clock 9 27 Memory RAS Feature 9 27 Installation 9...

Страница 15: ...Network Board Driver D 25 Adapter Fault Tolerance AFT Adaptive Load Balancing ALB D 25 Setting WOL D 27 Graphics Accelerator Driver D 28 Installing SCSI Controller Driver D 28 Installing SAS Controlle...

Страница 16: ...has been upgraded to Dynamic Disk F 2 Mounting MO Device F 2 About Removable Media F 2 Floppy Disk Drive F 2 About the Upgrade to Windows Server 2003 R2 F 2 About the System Partition Size F 4 Instal...

Страница 17: ...Chapter 1 Notes on Using Your Server This chapter includes information necessary for proper and safe operation of the server...

Страница 18: ...ossible danger or their vicinity in your server to inform the user that a hazardous situation may arise when operating the server Do not intentionally remove or damage any of the labels If you find an...

Страница 19: ...approved place Install the server on a standard EIA 19 inch rack assembly Do not install the rack containing the server in a place inappropriate to the rack installation environment Failure to follow...

Страница 20: ...Heat will also be generated if condensation is formed on dusty blades of the halfway inserted plug increasing the possibility of fire Use the authorized power cord only Use only the power cord that c...

Страница 21: ...ause some parts to fall to be broken and or to result in personal injury Insert hinges completely When installing the rack door make sure that hinge pins at top and bottom of the door are completely i...

Страница 22: ...other than specified in this User s Guide Failure to follow this instruction may cause a fire a dusty place a humid place such as near a boiler a place exposed to direct sunlight an unstable place Do...

Страница 23: ...uching an internal device cable or connector may cause an electric shock or a fire resulted from a short circuit Do not use any unauthorized interface cable Use only interface cables provided by Bull...

Страница 24: ...lling removing internal optional devices Touching any internal device of the server with its power cord connected to a power source may cause an electric shock even of the server is off powered Discon...

Страница 25: ...in injury Avoid contact with the server during thunderstorms Disconnect the power plug from the outlet when a thunderstorm is approaching If it starts thundering before you disconnect the power plug...

Страница 26: ...completes See Chapter 2 for details of POST When you have just turned off the server wait at least 30 seconds before turning it back on When unplug the power cord s from the server wait at least 30 se...

Страница 27: ...server Some non supported devices may be physically installed connected but cause failures of the server as well as a malfunction of the server Bull recommends you use Bull s genuine products Some th...

Страница 28: ...Provided Software To transfer or sell any software application that comes with the server to a third party the following requirements must be satisfied All provided software applications must be trans...

Страница 29: ...internal optical disk drive and the mouse For stable operation of the server Bull recommends you replace these components on a regular basis Consult with your service representative for replacement or...

Страница 30: ...the description If it does take the recommended measure for it 3 Check if the software required for operation of the server is properly installed If the server still appears to fail after you have ta...

Страница 31: ...adjustment is important to prevent the screen from reflecting bright lights and to make the display contents easy to see You will not be able to keep good working posture and you will feel more tired...

Страница 32: ...1 16 Notes on Using Your Server...

Страница 33: ...Chapter 2 General Description This chapter provides information that you should be familiar with before using the server It includes names and functions of the components and features of the server...

Страница 34: ...y capability such as file and print services e mail web access web site server etc Your server is housed and available as a rack mount system Your server conveniently installs into a standard EIA 19 i...

Страница 35: ...ription 2 3 External View The following figure shows the 3 5 inch disk model 1 Top cover Remove the top cover to install remove DIMM CPU or PCI boards 2 Release buttons Push these buttons to remove th...

Страница 36: ...dby mode 4 DISK ACCESS LED green amber This LED is green during access to the internal hard disk drives The LED turns amber when one of the internal hard disk drives fails 5 ACT LED green This LED is...

Страница 37: ...off the UID LEDs on the front and rear panels of the server Pressing the switch once turns on the LEDs Pressing it again turns them off The LED also goes on or flashes when software issues a command...

Страница 38: ...installed power supply unit 5 AC inlet Connect the power cord to this socket 6 Mouse connector Connect the mouse to this connector 7 Keyboard connector Connect the keyboard to this connector 8 LINK AC...

Страница 39: ...essing it again turns them off 14 UID LED blue This LED goes on when the UID switch is pressed The LED also goes on when software issues a command 15 USB connectors Connect device compliant with the U...

Страница 40: ...1 Front panel board 2 Backplane 3 Power supply unit 4 DIMM sockets 5 Mother board 6 PCI riser card 7 Top cover open sensor 8 RAID controller 9 Processor below the heat sink 10 Cooling fans 10 1 FAN1R...

Страница 41: ...rd 7 Top cover open sensor 8 Processor below the heat sink 9 Cooling fans 9 1 FAN1R 9 2 FAN2R 9 3 FAN3R 9 4 FAN4R 9 5 FAN5R 9 6 FAN6R 9 7 FAN7R 9 8 FAN1F 9 9 FAN 2F 9 9 FAN3F 9 11 FAN4F 9 12 FAN5F 9 1...

Страница 42: ...mper switch 11 CMOS clear jumper switch 12 Password clear jumper switch 13 RAID configuration jumper switch With 2 5 inch disk model leave the factory setting as is 14 Lithium battery 15 Connector for...

Страница 43: ...r and flashes it indicates that the server is in abnormal state The table below explains the STATUS LED indication the meanings and the procedures NOTES If NEC ESMPRO is installed you can confirm the...

Страница 44: ...the STATUS LED indication does not change when the fans are normal contact your sales representative A voltage alarm was detected All the power supply units failed On amber A temperature alarm was det...

Страница 45: ...le the server is connected to the LAN The LED flashes while the server is accessed via the LAN during transmission reception of packets The number next to the icon indicates the network port number on...

Страница 46: ...tinue operation However replace the hard disk drive as soon as possible and perform reconstruction rebuild processing The failing hard disk drive can be replaced in hot swap mode Flashing switching ba...

Страница 47: ...uild processing again Observe the following notes on using the auto rebuild function Do not turn the power off Once the power is turned off the auto build function does not start Let 90 seconds or mor...

Страница 48: ...when the network cable is normal the network LAN controller may be faulty In this case contact your sales representative Speed LEDs for data transmission ports This LED indicates whether each of the...

Страница 49: ...turned on If the LED does not go on when the server power switch is turned on or if it turns amber the power supply unit is probably faulty In this case contact your service representative to replace...

Страница 50: ...mote console feature Front monitor connector Self diagnosis PCI Express 2 0 x16 1 slot full height PCI Express 2 0 x8 1 slot low profile 2 PCI Express 2 0 x4 1 slot Dedicated to RAID Controller 2 Can...

Страница 51: ...itions fan failure or chassis intrusion To enable accurate monitoring the RMC maintains the nonvolatile Sensor Data Records SDRs from which sensor information can be retrieved The RMC provides an ISA...

Страница 52: ...er On Feature Wake On LAN The remote power on function turns on the server through a network It sends a special packet from the management computer to a remote server to turn it on if the server is of...

Страница 53: ...again To lock the bezel insert the key in the lock Turn the lock clockwise until it stops about a quarter turn The bezel is now locked and cannot be opened Software Locks via the BIOS SETUP Utility Th...

Страница 54: ...P State Performance State of processor that is defined in ACPI Advanced Configuration and Power Interface Thus the OS must support P State The following OSs support the power control feature OS that s...

Страница 55: ...Server 2008 The following event will be logged in Event Viewer if power control feature is used on Windows Server 2008 However it is not the problem in operating the system the event is logged becaus...

Страница 56: ...D F To update System BIOS Use this function to update the server s system BIOS or firmware See Chapter 8 To update Windows system Update the system in the Autorun menu See Chapter 6 updates the severa...

Страница 57: ...ration and setups with the NEC ESMPRO see Chapter 6 Available functions of the NEC ESMPRO depend on the OS you install Ask your service representative for details Maintenance Tools The Maintenance Too...

Страница 58: ...n not to press the POWER switch when you install or remove the front bezel Installing or Removing the Front Bezel When turning the power of the server on off accessing to the optical disk drive or ins...

Страница 59: ...tle to remove the tab from the frame and then remove the front bezel from the server To install the front bezel latch the tab at the left side of the front bezel on the server frame After the installa...

Страница 60: ...RTANT If the power cord is connected to a power control device such as a UPS Uninterruptive Power Supply make sure that the power control device is powered If the power cord is connected to the server...

Страница 61: ...the server the Bull logo appears on the display unit while POST is in progress To display the POST check results press Esc NOTE You can set the POST check results to appear on the display unit without...

Страница 62: ...te depending on the memory size of the server Also it may take approximately one minute for the screen display to appear after rebooting the server 2 Some messages appear upon completion of the memory...

Страница 63: ...e for 2 5 inch disk model 5 If the POST detects the optional add in card it display the message prompting you to launch the add in card BIOS configuration utility Ignore the message POST will automati...

Страница 64: ...Power Off Follow the procedure below to power off the server If the power cord of the server is connected to a UPS refer to the manual that comes with the UPS or the manual for the application that co...

Страница 65: ...n when the UID Unit ID switch on the front panel is pressed It goes off when the switch is pressed again Maintenance from the rear of the rack may be carried out in a dark narrow space The interface c...

Страница 66: ...details Do not leave the tray ejected from the optical disk drive Set a disc on the optical disk drive in the following procedure 1 Confirm that the power of the server is on with the POWER LED being...

Страница 67: ...tical disk drive occurs after setting a disc set it again correctly To take out the disc from the optical disk drive press the Eject button in the similar way in setting the disc to make the tray go o...

Страница 68: ...t a metal pin of approximately 1 2 mm in diameter and 100 mm in length a straightened large paper clip will make a substitute into the emergency hole on the right front of the optical disk drive and g...

Страница 69: ...nted side upward and gently put it on the tray Do not scratch the disc or write anything directly on it with a pencil or ball point pen Keep the disc away from cigarette smoke Do not leave the disc in...

Страница 70: ...2 38 General Description...

Страница 71: ...Chapter 3 Setting Up Your Server This chapter describes how to set up the server appropriate for your system on a step by step basis...

Страница 72: ...Connect the power cord to the server Turning on the server Power on the server to start software setup The process depends on the optional internal devices installed and the peripheral devices connec...

Страница 73: ...e ground line to a gas pipe CAUTION Observe the following instructions to use the server safely Failure to follow these instructions may cause a fire personal injury or property damage See pages 1 3 t...

Страница 74: ...e generating intense magnetic field such as a TV radio broadcast communication antenna power transmission wire and electromagnetic crane is placed If unavoidable contact your service representative to...

Страница 75: ...details Do not use any rack which does not conform to the relevant standard Always use the server in the specified place CAUTION Observe the following instructions to use the server safely Failure to...

Страница 76: ...er in the rack Preparation for installation When shipped from factory the left and right slide rails are fixed with tapes at the front and side faces to prevent from falling off during transportation...

Страница 77: ...r a click the rails are locked Pull the release levers on the left and right sides of the server toward direction indicated by an arrow white in the figure and remove them from the server while unlock...

Страница 78: ...emoved rail assemblies toward the direction indicated by an arrow in the figure to restore the original position IMPORTANT The removed rail assemblies are to be installed on the inner rails later Be v...

Страница 79: ...ws the right side front of the rack Install the rail assemblies to the right side rear and left side front and rear of the rack using the same procedure Make sure that the rail assembly is installed a...

Страница 80: ...may cause a fire personal injury or property damage See pages 1 3 to 1 12 for details Do not lift the server only by a single person Do not pinch your finger with mechanical components 1 Pull out the...

Страница 81: ...rver into the rail assemblies that are installed on the rack and then slowly push the server into the rack Rail assembly Inner rail at server side 3 If the server is locked on its way into the rack sl...

Страница 82: ...installation is incomplete either of rails may not go further on its way In such a case pull out the server completely until it is locked Then push the server in while unlocking the right and left sid...

Страница 83: ...Setting Up Your Server 3 13 Installing the Front Bezel 1 Install the front bezel so that the left tab on the front bezel engages with the chassis frame Tabs...

Страница 84: ...inch your finger with mechanical components Do not apply any load on the server being pulled out from the rack Do not pull out a device from the rack if the rack is unstable Do not leave more than one...

Страница 85: ...the server from the rack Release lever blue IMPORTANT Do not apply any load on the server pulled out from the rack Doing so may cause personal injury if the server drops 6 Firmly hold the server and t...

Страница 86: ...o not pinch your finger with mechanical components Do not apply any load on the server being pulled out from the rack Do not pull out a device from the rack if the rack is unstable Do not leave more t...

Страница 87: ...ed from top Viewed from front 5 While the rail assembly is being unlocked remove it from the rack 6 Insert the tool into the angle hole at the rear of rail assembly to unlock it Rotate the tool as sho...

Страница 88: ...ower cord of the Bull Server plugged to a power source Do not use any unauthorized interface cable IMPORTANT Power off the server and a peripheral device before connection Connecting a powered periphe...

Страница 89: ...000BASE TX 10BASE T Finally connect the provided power cord to the receptacle 1 1000BASE TX 10BASE T If connecting the server to UPS see the explanation below REAR USB device Keyboard Display unit 2 1...

Страница 90: ...ure to follow these instructions may cause a fire personal injury or property damage See pages 1 3 to 1 12 for details Do not plug the power cord in to an improper power source Do not connect the powe...

Страница 91: ...manual that comes with the UPS When the power cord from the server is connected to a UPS change the BIOS setup of the server to link with power supply from the UPS To power on the server from the UPS...

Страница 92: ...s the internal Power On Self Test POST POST automatically checks the system board CPU module memory keyboard and most installed peripheral devices IMPORTANT Always allow POST to complete before poweri...

Страница 93: ...e with the server See Chapter 6 for details MAKING BACKUP COPIES OF SYSTEM INFORMATION The system information includes the current BIOS settings and any specific information for the server Save the in...

Страница 94: ...3 24 Setting Up Your Server This page is intentionally left blank...

Страница 95: ...o change system configuration parameters This utility is pre installed in the flash memory of the server and ready to run The server is configured with the correct parameters using the SETUP utility a...

Страница 96: ...ou have previously set a password with the SETUP utility the password entry screen appears Enter the password Enter password Up to three password entries will be accepted If you fail to enter the pass...

Страница 97: ...he Main Advanced Security Server Boot or Exit menu and Changes the value parameter of the selected item When a submenu option an option preceded by is selected these keys are disabled Enter Press Ente...

Страница 98: ...ptions The SETUP utility has the following six major menus Main Advanced Security Server Boot Exit To set functions select a submenu from the above menus The following describes available functions an...

Страница 99: ...before the first access of a hard disk drive by the BIOS SATA Port 0 SATA Port 1 SATA Port 2 SATA Port 3 SATA Port 4 SATA Port 5 Select submenu Set the information on the device connected to each cha...

Страница 100: ...ssor 2 L3 Cache nnn KB Displays L3 cache size for processor 2 Active Processor Cores ALL 12 Specifies the number of valid cores in the processor Hyper Threading Technology Disabled Enabled Displayed o...

Страница 101: ...anced Chipset Control submenu Boot time Diagnostic Screen Enabled Disabled When disabled the BIOS will display the Bull logo during POST Press Esc to switch to the POST execution screen Reset Configur...

Страница 102: ...Error indicates the system is forcibly started with memory error View only Memory Retest Yes No Causes BIOS to retest all memory on the next boot Extended RAM Step 1MB 1KB Every location Disabled 1MB...

Страница 103: ...tem Factory set Onboard LAN submenu Option Parameter Description Your Setting LAN Controller Disabled Enabled If Disabled the BIOS will hold the embedded chip in reset LAN1 Option ROM Scan Disabled En...

Страница 104: ...3E8 2E8 Selects the base I O address for serial port A Interrupt IRQ 3 IRQ 4 Selects the interrupt for a serial port A USB 2 0 Controller Disabled Enabled Selects whether the USB 2 0 controller is ena...

Страница 105: ...mote power on function through a network is enabled or disabled Wake On Ring Disabled Enabled Specify whether the remote power on function through a serial port is enabled or disabled Wake On RTC Alar...

Страница 106: ...not modify Once set this can be disabled by setting it to a null string or by clearing password jumper on system board see Configuring Mother Board Jumpers in this Chapter Set User Password Up to eigh...

Страница 107: ...ressing the POWER switch for at least four seconds Disable USB Ports Disabled Front Rear Internal Front Rear Front Internal Rear Internal Front Rear Internal Enables or disables the USB ports Factory...

Страница 108: ...vate Note This section will switch on the TPM Reject Execute When Deactivate Disable is selected Physical Presence operations TPM configuration change was requested to State Deactivate Disable Note Th...

Страница 109: ...ify the processing at the occurrence of timeout during boot monitoring If Retry 3 times is selected the system is reset after the occurrence of timeout and OS boot is retried up to three times If Alwa...

Страница 110: ...below shows the operation when the AC power to the server is turn off once and then on again depending on the setting of AC LINK Setting of AC LINK System status before AC power off Stay Off Last Stat...

Страница 111: ...umber of the chassis View only Chassis Serial Number Displays the serial number of the chassis View only Onboard LAN1 MAC Address Displays the MAC address of the onboard LAN port 1 View only Onboard L...

Страница 112: ...Control None Xon Xoff CTS RTS CTS RTS CD Specify the flow control method Console Type PC ANSI VT100 VT UTF8 Specify the type of remote console Continue Redirection after POST Disabled Enabled Specify...

Страница 113: ...ress from DHCP server automatically If you intend to specify an IP address manually set to Disabled Web Interface HTTP Disabled Enabled Set to Enabled to use HTTP communication for Web interface HTTP...

Страница 114: ...ation also clears settings made in NEC ESMPRO Manager Before execution be sure make backup copy of setting information of NEC ESMPRO Manager NOTE Executing Save Custom Defaults Load Custom Defaults of...

Страница 115: ...ys the information on the device in the relevant indication To boot the server from a desired device the device must be registered as a boot device Up to eight boot devices can be registered 2 Pressin...

Страница 116: ...dified BIOS SETUP item values to CMOS Exit Discarding Changes Exit leaving CMOS unmodified User is prompted if any of the setup fields ware modified Load Setup Defaults Load default values for all BIO...

Страница 117: ...ws more than one hard disk drive HDD to be handled collectively In actual RAID can configure more than one HDDs as a single array disk group to operate the HDDs effectively This can bring higher perfo...

Страница 118: ...ID 0 1 6 RAID 1 2 2 RAID 5 3 6 RAID 6 3 6 IMPORTANT To use RAID 5 or RAID 6 with Internal RAID Controller you need to additionally install the optional RAID Upgrade Kit NOTE For details of the RAID le...

Страница 119: ...36 GB HDD 3 36 GB RAID Controller DG0 108 GB VD1 3 16 GB VD1 2 16 GB VD1 1 16 GB VD0 1 20GB VD0 2 20GB VD0 3 20GB VD0 RAID5 40 GB VD1 RAID5 32 GB Parity The parity means redundant data A single set of...

Страница 120: ...HDD number of HDDs RAID1 Mirroring Yes Two HDDs required Capacity capacity of single HDD RAID5 Striping of both data and redundant data Yes Three or more HDDs required Capacity capacity of single HDD...

Страница 121: ...d mirroring When data is written onto a single HDD the same data is written onto another HDD If either of the HDDs is defective the other HDD containing the same data can substitute for the defective...

Страница 122: ...o parity blocks distributed across all member disks This mode is called striping with duplex and distributed parity Accordingly the total capacity assigned to the parity is just the same as the capaci...

Страница 123: ...ration jumper switch on the mother board NOTE The RAID System is factory set to Disabled WARNING Observe the following instructions to use the server safely Failure to follow these instructions may re...

Страница 124: ...tion 2 3 on jumper block 6 Reinstall the jumper on position 1 2 on jumper block 7 Reinstall the top cover removed in Step 2 8 Plug the power cord to your server and turn on the server 9 Run the BIOS S...

Страница 125: ...Configuration Utility starts If you fail to press Ctrl M and the system proceeds without displaying the following menu screen reboot the system and press Ctrl M on POST screen LSI Software RAID Confi...

Страница 126: ...ze Initialize virtual drive Check Consistency Check virtual drive redundancy View Update Parameters Display virtual drive information RAID Display RAID level SIZE Display virtual drive capacity Stripe...

Страница 127: ...Management Menu Select View add Configuration to add configuration IMPORTANT Creating a configuration using New Configuration menu clears the existing configuration information To add configuration i...

Страница 128: ...en Upon completion of SCAN DEVICE the New Configuration ARRAY SELECTION MENU screen appears 3 Move the cursor onto the hard disk drive to be packed by using the cursor keys and then press Space to sel...

Страница 129: ...RAID level varies depending on the number of hard disk drives that configures a pack 2 Size Sets virtual drive size Up to 8 virtual drives can be created per RAID Controller 3 DWC Sets parameter for D...

Страница 130: ...een and then select Yes to save the configuration 10 When the confirmation message shows that the configuration has been saved press Esc to return to the TOP menu screen 11 On the TOP menu screen sele...

Страница 131: ...details 16 Press Esc to return to the TOP menu and exit from LSI Software RAID Configuration Utility IMPORTANT Be sure to execute Check Consistency after creating configuration Inconsistency may be de...

Страница 132: ...and then press Space to select it Multiple hard disk drives can be selected simultaneous rebuilding 5 The FAIL indication for the hard disk drive selected starts blinking 6 When the hard disk drive ha...

Страница 133: ...ftware RAID Configuration Utility 3 Select Objects Physical Drive from the TOP menu The Objects PHYSICAL DRIVE SELECTION MENU screen appears 4 Move the cursor onto the hard disk drive to be used as ho...

Страница 134: ...oftware RAID Configuration Utility IMPORTANT Select Objects Physical Drive Port X Change Drv State to cancel the hot spare setting When two or more hard disk drives of the same capacity are assigned a...

Страница 135: ...sor onto the virtual drive to be checked and press Space to select it 4 When the virtual drive has been selected press F10 to start consistency check 5 A confirmation screen appears Select Yes The con...

Страница 136: ...Configuration Utility cannot delete each virtual drive Use Universal RAID Utility instead Force Online Puts a hard disk drive being in the FAIL status online Select Objects Physical Drive select hard...

Страница 137: ...AID Viewer or using RAID Controller X in the RAID Controller properties on the raidcmd command You can also see the adapter number managed by the LSI Software RAID Configuration Utility in ID in theRA...

Страница 138: ...RAID Controller X Physical Device Y and ID in the Physical Device properties on the raidcmd command Setting of Priority LSI Software RAID Configuration Utility displays and sets Rebuild Priority and...

Страница 139: ...Rate LSI Software RAID Configuration Utility Low 5 NOTES The LSI Software RAID Configuration Utility can set FGI Rate Foreground Initialize and BGI Rate Background Initialize Priority But Universal RA...

Страница 140: ...tart the rebuild without using any utility such as Universal RAID Utility The auto rebuild includes two modes as follows Standby rebuild Automatic rebuild by using hot spares In the configuration incl...

Страница 141: ...RAID Utility If the system is restarted while running Patrol Read Patrol Read resumes from the point where it was stopped Consistency Check The Consistency Check is used to check the consistency among...

Страница 142: ...A Rebuild has already been executed and completed normally before executing a Background Initialize for RAID5 only Yes is specified for Disable BGI in VD Definition Virtual disk is in a degraded or o...

Страница 143: ...ution After execution RAID level Number of HDDs RAID level Number of HDDs Description RAID0 x RAID0 x Capacity increased equivalent to HDDs RAID0 1 RAID1 2 Capacity remains unchanged RAID0 x RAID5 x C...

Страница 144: ...virtual disk then execute a Reconstruction During the Reconstruction process do not shut down or reboot the server If the server is shut down by an unforeseen accident such as power interruption turn...

Страница 145: ...on of the allocation status of the Hard Disk Drive Creation of the virtual drive Setting of RAID level Setting of Stripe Block size Setting of Read Policy Write Policy IO Policy Indication of the conf...

Страница 146: ...C ESMPRO Manager 5 The physical drive numbers shown in WebBIOS and those shown in the Universal RAID Utility are identified as follows WebBIOS Slot number shown in Physical View 1 The slot number the...

Страница 147: ...Configuring Your Server 4 53 Property of Physical Device in the Universal RAID Utility...

Страница 148: ...Dev X MegaRAID SAS 8708EM2 FW package X X X XXXX 0 Virtual Drive s found on the host adapter 0 Virtual Drive s handled by BIOS Press Ctrl H for WebBIOS POST screen image with no virtual drive assigne...

Страница 149: ...that appears first on WebBIOS In the Adapter No box select the adapter you want to manage with WebBIOS then click Start When the adapter is selected on Adapter Selection the WebBIOS Top Menu appears I...

Страница 150: ...ate The indication is red Initialization The relevant Virtual Disk is being initialized ConsistencyCheck Consistency Check is being performed for the relevant Virtual Disk Rebuild The relevant Virtual...

Страница 151: ...T status The information of the Hard Disk Drive that has one or more Pred Fail Count is displayed in yellow Indicates that the device has failed in the past You can use the device as usual however we...

Страница 152: ...nfiguring Your Server Controller Properties When you click Controller Properties on the WebBIOS Top Menu the configuration information is displayed Click Next to see the detailed settings of this cont...

Страница 153: ...figuring Your Server 4 59 The detailed setting is continued on the next page Click Next to view more information Clicking Supported in Schedule CC opens the screen for setting scheduled consistency ch...

Страница 154: ...Control Disabled Disabled Does not issue an alarm Enabled Issues an alarm Silence Stops an alarm if beeped Permitted 2 Patrol Read Rate 30 Recommended value 30 Permitted Cache Flush Interval 4 Prohibi...

Страница 155: ...as Present Clicking Present opens the Battery Status screen as shown below IMPORTANT You cannot change values for Auto Learn Period Next Learn Time and Learn Delay Interval NOTES The value shown in C...

Страница 156: ...ns another configuration information the Foreign Configuration screen as shown below appears To use the Hard Disk Drive as a new one click Clear to clear the configuration information of the Hard Disk...

Страница 157: ...ve Current XX Default NONE Selects a virtual drive to start the operating system If the system contains several virtual drives and you want to start the operating system from the virtual drive other t...

Страница 158: ...lick Drives on the WebBIOS Top Menu the screen for operating the connected physical drive appears IMPORTANT If no device is connected the upper right column of the screen will be blank Use this menu o...

Страница 159: ...ollowing procedures to check the Physical Drive Properties Shown below is an example to check the properties of a physical drive 1 Click the Physical Drive you want to check 2 Click the checkbox for P...

Страница 160: ...of the selected Hard Disk Drive in Powersave state This is indicated on the Hard Disk Drive of which power status is On and the status is Unconfigured Good Undo Removal Make the power status of the s...

Страница 161: ...er controlled by WebBIOS to configure each adapter Clicking Controller Selection on the WebBIOS top menu opens the Adapter Selection screen Physical View Logical View If the virtual drive has been con...

Страница 162: ...Server Exit When you click Exit on the WebBIOS Top Menu a confirmation screen to exit from WebBIOS is displayed Click Yes to exit from WebBIOS The screen as shown below appears when WebBIOS is termina...

Страница 163: ...shown below appears Select the relevant operation and click Next at the lower right of the screen Clear Configuration Allows you to clear existing configuration RAID information New Configuration Cle...

Страница 164: ...Configuration and click Next IMPORTANT The RAID Controller does not support the Automatic Configuration feature Use this menu to define several Hard Disk Drives as a drive group DG 1 While pressing Ct...

Страница 165: ...Your Server 4 71 3 A new DG is defined in the Drive Groups frame To define the new DG click Accept DG at the lower right of the screen 4 After the DG has been defined click Next at the lower right of...

Страница 166: ...ition screen appears 6 Select a DG to define VD from Array With Free Space frame then click Add to SPAN The DG is defined in the Span field to the right 7 After the Span has been defined click Next at...

Страница 167: ...different number of Hard Disk Drives Define the virtual drive VD in the DG that has been created in previous step When the DG has been defined the VD Definition screen is displayed In the Next LD Poss...

Страница 168: ...al Upgrade Kit If the Upgrade Kit is not installed do not select RAID5 that may appear in RAID Level box If selected you will fail to save the configuration information In such a case you need to defi...

Страница 169: ...er right of the screen 7 The confirmation message Save this Configuration appears Click Yes to save the configuration 8 The confirmation message Want to Initialize the New Virtual Drives appears To pe...

Страница 170: ...4 76 Configuring Your Server 10 The WebBIOS Top Menu is displayed The Virtual Drives you have created are displayed in the right frame of the screen...

Страница 171: ...00 or RAID60 They are not supported 1 Click Configuration Wizard on the WebBIOS Top Menu to start Wizard 2 While pressing Ctrl click the Hard Disk Drives to be included in the DG In the example two DG...

Страница 172: ...er DG using the similar procedures After DGs have been defined click Next at the lower right of the screen 5 When DGs are defined the Span Definition screen is displayed 6 Select DG0 in the Array With...

Страница 173: ...Then select DG1 and click Add to SPAN When the two DGs are defined in the Span field right column click Next at the lower right of the screen 8 The VD Definition screen is displayed Enter the necessa...

Страница 174: ...right of the screen IMPORTANT RAID10 may be configured with three or more Hard Disk Drives in each span However with this controller each drive group must contain only two Hard Disk Drives 10 On the...

Страница 175: ...ata on the new Virtual Drives will be lost Want to Initialize appears Click Yes to perform Fast Initialize 13 the Virtual Drives operation screen is displayed If no other operation is required click H...

Страница 176: ...ed Normal WriteBack Unchecked Constant WriteBack Recommended value Checked IO Policy Direct Cached Recommended value Direct Disk CachePolicy Unchanged Enabled Disabled Recommended value Disabled Disab...

Страница 177: ...ry charged status or existence of battery Be sure to use UPS when specifying this mode for write policy WThru Write through mode The controller does not use cache memory for writing data This mode can...

Страница 178: ...security however the writing performance is lower than the one in Enabled mode It is recommended to use this mode for the sake of data security IMPORTANT If Unchanged is specified for Disk Cache Polic...

Страница 179: ...select a VD for which a Check Consistency should be performed 4 In the lower right frame of theVirtual Drives screen select Check Consistency 5 Make sure that Check Consistency is checked and click Go...

Страница 180: ...ves screen 8 Click Home at the lower left corner of the Virtual Drives screen to return to the Top Menu IMPORTANT A lot of inconsistency may be detected if the Check Consistency process is performed i...

Страница 181: ...isk Drive in hot swap mode be sure to replace the device while the operating system or WebBIOS is running You can view the progress of the rebuild process on the Universal RAID Utility screen or click...

Страница 182: ...e virtual drives as described below 1 Start WebBIOS Make sure that the status for the replaced Hard Disk Drive is indicated as Unconfigured Good in the right frame of the Top Menu In the example below...

Страница 183: ...NT Click Home while the background task such as Consistency Check Rebuild or Reconstruction is being executed When the progress indication bar is being displayed the background task may be processed a...

Страница 184: ...4 90 Configuring Your Server 7 When the rebuild completes the status for the Physical Drive is Online and the one of the Virtual Drive is Optimal...

Страница 185: ...ssign a newly added Hard Disk Drive as Hot Spare Disk 1 Start WebBIOS Make sure that the status for the added Hard Disk Drive is indicated as Unconfigured Good in the right frame of the Top Menu 2 Sel...

Страница 186: ...obal HSP Indicates the Hot Spare available for all DGs Dedicated HSP Indicates the Hot Spare available only for the specific DG You need to specify the target DG 5 The status for the newly connected H...

Страница 187: ...Configuring Your Server 4 93 6 Click Home at the lower left of the screen to go back to the WebBIOS Top Menu...

Страница 188: ...gured with four Hard Disk Drives 1 Start WebBIOS Make sure that the status for the added Hard Disk Drive is indicated as Unconfigured Good in the right frame of the Top Menu 2 Select a VD you want to...

Страница 189: ...the WebBIOS Top Menu IMPORTANT The capacity of the virtual drive may be incorrectly displayed after reconstruction In this case perform a Scan Devices process from the Top Menu Click Home while the ba...

Страница 190: ...heck the slot of the Hard Disk Drive before adding a VD or hot spare disks reconstructing a VD or replacing a Hard Disk Drive How to execute the Locate command using WebBIOS 1 In the WebBIOS Top Menu...

Страница 191: ...l Drives screen select the VD for which you want to perform a Slow Initialize 4 In the lower right frame of the Virtual Drives screen select Slow Initialize 5 Make sure that Slow Initialize is checked...

Страница 192: ...rive WebBIOS identifies the Virtual Disk starting from 0 You can see a number of Virtual Disk using VD X in Virtual Drives The Universal RAID Utility identifies the Logical Drive starting from 1 You c...

Страница 193: ...arting with 1 To view these numbers in the Universal RAID Utility select properties of the Hard Disk Drive and see Number and ID Enclosure and Slot RAID Viewer or RAID Controller X Physical Drive Y an...

Страница 194: ...In addition changing the Initialization Priority by raidcmd command will also fail See the table below for correspondence Setting values of WebBIOS and the display levels of Universal RAID Utility Ite...

Страница 195: ...sing the Universal RAID Utility at least four Hard Disk Drives are required If you want to create a Logical Drive of RAID6 with three Hard Disk Drives you need to use WebBIOS IMPORTANT WebBIOS does no...

Страница 196: ...OS SETUP utility and execute the following menus to reconfigure your mother board Load Setup Defaults in the Exit menu Memory Retest of Memory Configuration in the Advanced menu Processor Retest of Pr...

Страница 197: ...nd line to a gas pipe CAUTION Observe the following instructions to use the server safely Failure to follow these instructions may result in death or serious personal injury See pages 1 3 to 1 12 for...

Страница 198: ...turn on the server 8 Press F2 at the prompt to run the BIOS SETUP utility and select Load Setup Defaults at the Exit menu Clearing Password 1 See the section Preparing for Installation and Removal as...

Страница 199: ...rprise 32 bit x86 Edition Microsoft Windows Server 2003 R2 Standard Edition Microsoft Windows Server 2003 R2 Enterprise Edition Microsoft Windows Server 2003 Standard Edition Microsoft Windows Server...

Страница 200: ...in order to save or backup the installation parameters If you want to set up the server using parameters defined previously execute the Express Setup using an existing parameters file NOTES If you wan...

Страница 201: ...dows Server 2008 64 bit x64 Edition If you want to install it see Appendix D To install other operating systems contact your sales dealer or the maintenance service representative BIOS Settings Check...

Страница 202: ...the following hardware components Installing on the Mirrored Volume When re installing the OS to a hard disk drive which has been upgraded to Dynamic Disk only the simple dynamic volume is available...

Страница 203: ...e hard disk drive upgraded to Dynamic Disk remains If you want to keep the current partition see Appendix D to re install the system Using RAID Controller When you install Windows Server 2008 32bit x8...

Страница 204: ...rtition is 4095MB If the above paging file size exceeds 4095MB specify 4095MB for the paging file size The maximum dump file size for the system with more than 2GB memory mounted is 2048MB 300MB If yo...

Страница 205: ...e parameters Step 11 Next Start Express Setup Step 12 Next RAID Configuration Perform Create the OS partition format Copying Windows driver Copying Selected Application Remove the Floppy Disk and CD D...

Страница 206: ...device on and then turn on the server 2 Insert the ExpressBuilder DVD into the optical disk drive of the server 3 Press the RESET switch or press Ctrl Alt and Delete to reboot from the ExpressBuilder...

Страница 207: ...Installing the Operating System with Express Setup 5 9 4 Select English from the Select Language click OK 5 Select Perform the Express setup from the Top Menu click Next...

Страница 208: ...o not load parameters 1 Select Do not load parameters 2 Click Next NOTE If a floppy disk drive is not connected select this item Load parameters 1 Insert the floppy disk containing the parameters file...

Страница 209: ...p 5 11 7 Select theOperating System Select Install the Windows 32bit editions from the menu click Next 8 Enter the setting of a logical drive The Enter RAID settings steps are displayed Confirm the pa...

Страница 210: ...oard Supported by ExpressBuilder described earlier in this chapter When you use RAID Controller if Skip the logical drive creation is not selected in the Enter RAID settings screen refer to RAID Confi...

Страница 211: ...ate a new partition at Windows system drive settings the contents of the hard disk will be deleted If Use existing partitions is selected ExpressBuilder installs the Operating System on the 1st partit...

Страница 212: ...parameters steps are displayed Confirm the parameters modify if necessary and then click Next IMPORTANT Computer name and Administrator password that satisfy the next conditions are required More than...

Страница 213: ...network protocol The Enter Network Protocol steps are displayed Confirm the parameters modify if necessary and then click Next 12 Enter the domain or workgroup name to be used The Enter domain account...

Страница 214: ...rating System with Express Setup 13 Select the installing components The Select Windows components steps are displayed Confirm the parameters modify if necessary and then click Next Full Installation...

Страница 215: ...and then click Next 15 Save the parameters The Save parameters steps are displayed If you want to save the parameters set the free formatted floppy disk Select Save parameters enter the file path of t...

Страница 216: ...Storage Driver and follow the on screen messages 18 Remove the ExpressBuilder DVD from the optical disk drive when prompted If you proceed with the setup by using setup parameter file remove the flopp...

Страница 217: ...m with Express Setup 5 19 20 The Agree Software License Agreement screen appears Read the license terms carefully If you agree select I accept the license terms and then click Next 21 When the followi...

Страница 218: ...p 22 When the following message appears press Ctrl Alt Del 23 Log on to the system Full Installation When the following screen appears enter your password into Password and click Server Core Installat...

Страница 219: ...enter Administrator into UserName your password into Password and click Hereinafter follow the on screen instructions Now the Setup using Express Setup has completed After Express Setup has completed...

Страница 220: ...ters teamed for network redundancy Configure the settings after reinstalling the LAN driver and PROSet To remove the team see Adapter Fault Tolerance AFT AdaptiveLoad Balancing ALB 2 In Control Panel...

Страница 221: ...ng the Operating System with Express Setup 5 23 4 Select Remove and click Next 5 Click Remove Uninstallation starts automatically 6 When InstallShield Wizard Completed appears click Finish Restart the...

Страница 222: ...ilable in Network and Dial up Connection NOTE We recommend you add Network Monitor at Adding Services Network Monitor can monitor the frame or the packet that the computer installing Network Monitor s...

Страница 223: ...pecified as a group of Adaptive Load Balancing ALB can be connected only to the Switching Hub When replacing the mother board or an optional network card make sure to remove the adapter teaming before...

Страница 224: ...firmed by the following procedure 1 Click TEAM Team name from Device manager Network adapters 2 Click Settings and confirm Adapters in the team list 10 Click Test Switch Run test to confirm the adapte...

Страница 225: ...Open the Device Manager 2 Click Network adapters and open the TEAM Team name properties 3 Click the Setting tab 4 Click the Remove Team button 5 Click Yes to the message 6 Confirm the TEAM Team name...

Страница 226: ...in Wake On LAN according to the following list Setting item Default setting Change setting Wake On Directed Packet ON OFF Wake On Magic Packet ON OFF Wake on Magic Packet from power off state OFF ON...

Страница 227: ...celerator Driver in Appendix D if you want to reinstall the driver individually Installing SCSI Controller Driver Adaptec 29160LP 29320ALP ASC 29320LPE SCSI U320 PCI E If you use the SCSI Controllers...

Страница 228: ...rs on my computer 6 Click Have Disk 7 Insert ExpressBuilder DVD into the optical disk drive enter drive letter 009 win winnt oemfd ws2008 fd1 megasas into Copy manufacturer s files from and click OK 8...

Страница 229: ...in Windows boot loader The setting for PAE option is now completed Refer to the following site about Bcdedit exe Boot Configuration Data Editor Frequently Asked Questions http technet microsoft com en...

Страница 230: ...the Express Setup About the Windows family This computer supports the following Windows editions Microsoft Windows Server 2003 Standard Edition Microsoft Windows Server 2003 Enterprise Edition herein...

Страница 231: ...Server 2003 R2 x64 Edition OS installation media with Service Pack 2 OS installation media No Service Pack Service Pack 2 OS installation media No Service Pack Windows Server 2003 R2 OS installation m...

Страница 232: ...lers supporting installation of OS with Express Setup Internal RAID Controller LSI Logic SAS CTRL 8708EM2 RAID Controller 128MB RAID0 1 LSI Logic SAS CTRL 8708EM2 RAID Controller 128MB RAID0 1 5 6 LSI...

Страница 233: ...nagement Mounting MO Device Do not mount an MO device on this computer during the Windows installation About Removable Media Do not set removable media such as DAT into the device mounted on this comp...

Страница 234: ...file size is recommended for collecting debug information memory dump The paging file with initial size large enough to store the dump file in the boot drive is required Correct debug information migh...

Страница 235: ...ion equivalent to the dump file size is to be written to a separate disk If the disk does not have enough free space to enable the dump file size to be written then after installing the system using t...

Страница 236: ...s Step 11 Next Start Express Setup Step 12 Next RAID Configuration Perform Create the OS partition format Copying Windows driver Copying Selected Application Remove the Floppy Disk and CD DVD ROM from...

Страница 237: ...ilder DVD into the optical disk drive of the server 3 Press the RESET switch or press Ctrl Alt and Delete to reboot from the ExpressBuilder You may also turn off and then on again to reboot the server...

Страница 238: ...o not load parameters 1 Select Do not load parameters 2 Click Next NOTE If a floppy disk drive is not connected select this item Load parameters 1 Insert the floppy disk containing the parameters file...

Страница 239: ...y and then click Next NOTES You can use only the physical devices that have an identical model number to configure the logical drive If the process does not finish normally the driver may not be store...

Страница 240: ...the connected hard disk drive You cannot specify a logical drive larger than 2 097 144MB in a RAID system If you select Create a new partition at Windows system drive settings the contents of the har...

Страница 241: ...ps are displayed Confirm the parameters modify if necessary and then click Next NOTE Even if you do not enter a value into Administrator password and Confirm password zzzzz is displayed 11 Enter the s...

Страница 242: ...firm the parameters modify if necessary and then click Next 13 Select the installing components The Select Windows components steps are displayed Confirm the parameters modify if necessary and then cl...

Страница 243: ...displayed If you want to save the parameters insert the free formatted floppy disk Select Save parameters enter the file path of the parameters files into the text box and click Next If not select Do...

Страница 244: ...r a floppy disk attached to the Mass Storage Driver and follow the on screen instructions 18 Remove the ExpressBuilder DVD from the optical disk drive when prompted If you proceed with the setup using...

Страница 245: ...ical disk drive IMPORTANT If you install Windows Server 2003 R2 do not apply Service Pack using Express Setup If you install Service Pack apply Windows Server 2003 R2 DISC 2 once Express Setup is comp...

Страница 246: ...eatures Follow the procedure below to install PROSet 1 Insert the ExpressBuilder DVD into the optical disk drive If the autorun menu is displayed close it 2 The Windows Explorer dialog starts Procedur...

Страница 247: ...for the HUB 4 Click OK Also add or delete any protocols and services if necessary This procedure can also be applied on the properties dialog box for the local area network which appears from the Netw...

Страница 248: ...er to the installation manual provided with the board Installation of the Optional Network Board Driver 1 Start Device Manager 2 Click Network adapters and double click Network Adapter Name Network Ad...

Страница 249: ...ing ALB can be connected to only a Switching Hub When replacing the mother board or an optional network card make sure to remove the adapter team before and recreate the adapter team once the replacem...

Страница 250: ...procedure 1 Click TEAM Team name from Device manager Network adapters 2 Click Settings and confirm Adapters in team list 10 Click Test Switch Run test to confirm the adapter team is properly setup Co...

Страница 251: ...ork Connection Intel R 82576 Gigabit Dual Port Server Network Connection 2 to open the adapter Properties 3 Click the Power Management tab and change setting in Wake On LAN according to the following...

Страница 252: ...Click the Power Management tab and change setting in Wake On LAN according to the following list Setting item Default setting Change setting Wake On Directed Packet ON ON Wake On Magic Packet ON ON Wa...

Страница 253: ...n you want to reinstall the driver individually Installing SCSI Controller Driver ADAPTEC 29160LP ADAPTEC 29320ALP Adaptec ASC 29320LPE SCSI U320 PCI E If you use the SCSI Controllers refered above up...

Страница 254: ...Administrative Tools Computer Management 2 Double click the RAID Controller which Device Manager lists as Other device 3 Click Update Driver 4 When the Update Device Driver Wizard appears select No n...

Страница 255: ...erties dialog box will be shown 3 Click the Advanced tab and then click Settings under Setup and Recovery 4 Under System Setup click Edit to open Boot ini 5 Add PAE to Operating Systems section in Boo...

Страница 256: ...d only to specify the memory dump If any trouble occurs after specifying the process below a message informing that the system has a virtual memory shortage may appear but continue to start the system...

Страница 257: ...mmend you specify Complete Memory Dump to write the debug information If the mounted memory size is larger than 2GB Complete Memory Dump cannot be specified so specify Kernel Memory Dump instead Speci...

Страница 258: ...y dump A paging file with an initial size large enough to store the dump file in the boot drive is required Correct debug information might not be collected due to a virtual memory shortage when the p...

Страница 259: ...ump Customers need only to specify the memory dump If any trouble occurs after specifying the process below a message informing that the system has a virtual memory shortage may appear but continue to...

Страница 260: ...Verify the size of the empty space in the debugging information memory dump write destination drive Windows Server 2003 We recommend you specify Complete Memory Dump to write the debug information If...

Страница 261: ...Total paging file size for all drives and click Set IMPORTANT The above mentioned paging file size is recommended for collecting debug information memory dump A paging file with an initial size large...

Страница 262: ...d in the following directory C Users User Name AppData Local Temp NOTE The folder may be treated as hidden folder If the folder does not appear run Explorer and select Tools Folder Options View and ch...

Страница 263: ...dows dialog box appears 3 Specify the location to store the diagnostic information in the Log File Path box The diagnostic information will be stored with the file name DRWTSN32 LOG NOTE You cannot sp...

Страница 264: ...ate a new capture tab or select New in the File menu and click Capture A new tab for capturing a network trace is created 3 On the Select Networks window select a network you want to capture a trace 4...

Страница 265: ...onents Wizard dialog box appears again so click Next 7 If the setup asks to install the disk insert the OS CD ROM into the optical disk drive and click OK 8 Click Finish in the Windows Component Wizar...

Страница 266: ...ng system when the following message appears The following list shows the existing partitions and unpartitioned space on this computer Use the UP and DOWN ARROW keys to select an item in the list Cann...

Страница 267: ...the window 3 Right click the volume you want to modify the drive letter and specify the Change Drive Letter and Path 4 Click Yes 5 Choose the Assign a drive letter and specify the drive letter you wa...

Страница 268: ...UPDATING THE SYSTEM IMPORTANT If you install Windows Server 2003 CD ROM which contains Service Pack 2 to your system you do not have to apply Service Pack 2 again Updating the System is executed by E...

Страница 269: ...mation after completing the system setup Without the backup data you will not be able to recover the information You can save the information as follows 1 Insert the ExpressBuilder DVD into the optica...

Страница 270: ...he Load parameters screen is displayed if you do not need to load parameters select Do not load parameters and click Next 4 Select Install other Operating System at Select OS steps and then click Next...

Страница 271: ...der DVD 4 Select Load the optional driver into the ExpressBuilder from the Top menu click Next Insert the driver disk for the mass storage controller Press the Perform button NOTE By choosing this opt...

Страница 272: ...5 74 Installing the Operating System with Express Setup This page is intentionally left blank...

Страница 273: ...Chapter 6 Installing and Using Utilities This section describes how to use the ExpressBuilder DVD that comes with your server and to install the utilities stored on the ExpressBuilder...

Страница 274: ...XPRESSBUILDER The ExpressBuilder helps you install the Operating system the Management software or use the maintenance utilities When you insert the ExpressBuilder disk into the DVD drive and reboot t...

Страница 275: ...attention to the automatic reboot that occurs after 72 hours after start You can use the Express Setup see Chapter 5 or the following functions from this menu Create the OEM Disk You can create the Wi...

Страница 276: ...OS FW Updating You can update the system BIOS by using the floppy disk prepare a 3 5 floppy disk ROM DOS Startup FD The ROM DOS Startup FD is used for starting the ROM DOS system Test and diagnostics...

Страница 277: ...If you want to operate this computer via the BIOS redirection the console less function select this item NOTE If you operate this computer via the Remote KVM function select the Tool menu Normal mode...

Страница 278: ...ft Windows XP Vista or Windows Server 2003 or later Some documents are provided in PDF format Use the Adobe Reader to view or print these documents If the menu does not appear select My computer by us...

Страница 279: ...cally except for a few key inputs to confirm the specification Also you can install the system with the same specification as before when re installing the system We recommend you create Parameter fil...

Страница 280: ...nstallation and create Parameter file Follow the procedure below IMPORTANT Do not remove the ExpressBuilder DVD from the drive during a parameter file creation 1 Start the OS 2 Insert the ExpressBuild...

Страница 281: ...Installing and Using Utilities 6 9 4 Click Parameter File Creator Parameter File Creator appears...

Страница 282: ...Using Utilities 5 The Load Parameters step is displayed Select Do not load parameters from the menu click Next 6 Select the Operating System to install Select Install the Windows 32bit editions from...

Страница 283: ...es Parameter File Creator displays the upper limit that the RAID Controller can support The total of The number of physical devices used to create the logical drive and The number of the physical devi...

Страница 284: ...g Utilities 8 Specify the medium to install and the Windows system partition The Specify medium Partition steps are displayed Confirm the parameters modify if necessary then click Next Windows Server...

Страница 285: ...Create a new partition in Windows system drive settings the contents of the hard disk will be deleted If Use existing partitions is selected ExpressBuilder installs the Operating System to the 1st par...

Страница 286: ...sing Utilities 9 Enter the user information and the client license mode The Enter basic parameters steps are displayed Confirm the parameters modify if necessary and then click Next Windows Server 200...

Страница 287: ...not input value into Administrator password and Confirm password zzzzz is displayed 10 Enter the setting of the network protocol The Enter network protocol steps are displayed Confirm the parameters m...

Страница 288: ...Enter domain account steps are displayed Confirm the parameters modify if necessary then click Next 12 Select the components to install The Select Windows components steps are displayed Confirm the pa...

Страница 289: ...Installing and Using Utilities 6 17 13 Select the applications to install The Select applications steps are displayed Confirm the parameters modify if necessary then click Next Windows Server 2008...

Страница 290: ...ers Save parameters steps are displayed If you want to save the parameters insert the blank formatted floppy disk Select Save parameters enter the file path of the parameters files into the text box a...

Страница 291: ...n created Click Yes to exit Parameter File Creator NOTES If you modify the existing information file parameter file click Load Parameters in the Load Parameters screen Refer to the help to modify info...

Страница 292: ...me features of NEC ESMPRO Manager include Hardware and software server configuration Hardware resources mounted in servers such as CPU memory modules disks RAID System and LAN boards Software resource...

Страница 293: ...LSI Logic SAS CTRL 8708EM2 256 MB RAID0 1 5 6 Before attempting to operate the Universal RAID Utility read the Universal RAID Utility Ver2 0 User s Guide included in ExpressBuilder DVD The manual expl...

Страница 294: ...86 If CPU architecture is x64 Install the NET Framework Ver2 0 Redistributable Package x64 in Autorun Menu for the setup of Microsoft NET Framework 2 0 Click Setup Windows Install the Microsoft Visual...

Страница 295: ...network please use the remote console feature ex Remote Desktop of Windows Easy Configuration You cannot use the Easy Configuration feature for the LSI Embedded MegaRAID Creating Logical Drive of RAID...

Страница 296: ...on Setup software then on Product Info Collection Utility 3 The installation starts It is installed in System drive ezclct folder IMPORTANT Please log on to the system with the administrator privilege...

Страница 297: ...ged the hardware configuration or BIOS configuration select System Information Management and then Save of the Off line Maintenance Utility to make a backup copy of the system information Also make a...

Страница 298: ...pages 1 3 to 1 12 for details Do not disassemble repair or alter the server Do not remove the lithium battery Disconnect the power plug before working with the server CAUTION Observe the following ins...

Страница 299: ...e server must be kept dry Do not moisten them with water 1 Make sure that the server is off powered the POWER LED goes off 2 Unplug the power cord of the server from a power outlet 3 Wipe off dust fro...

Страница 300: ...interior of the server entails powering off the server and removing the top cover You will need a small vacuum cleaner with plastic tipped nozzle and electrostatic protection computer grade canned ai...

Страница 301: ...4 Take out the ball from the mouse Cover the bottom of the mouse with your hand and turn your hand holding the mouse the mouse is on your palm with the button upward The mouse ball is released onto yo...

Страница 302: ...e tray NOTE Do not touch the signal side of the disc with your hand 4 Wipe the tray with a dry soft cloth IMPORTANT Do not wipe the lens of the optical disk drive Doing so may damage the lens and may...

Страница 303: ...em Test Items The following items are tested in system diagnostics Memory CPU cache memory Hard disk drive used as a system IMPORTANT When executing the system diagnostics make sure to disconnect the...

Страница 304: ...t to execute System Diagnostics with remote console The LAN connection is not for System Diagnostics Procedures to start the diagnostics program are as follows 1 Shutdown the OS and power off the serv...

Страница 305: ...stics tool title Shows the name and version of the diagnostic tool Test window title Shows the progress of the diagnostics Test End is displayed when the diagnostics completes Test result Shows the st...

Страница 306: ...connected devices Log Info Shows the log information of the diagnostics It can be saved on a floppy disk To save it on a floppy disk insert a formatted floppy disk to the floppy disk drive and select...

Страница 307: ...ocated stored due to a change in the floor layout to a great extent contact the service representative Make sure to make a backup copy of your valuable data in the hard disk drive if any Make sure not...

Страница 308: ...7 12 Maintenance This page is intentionally left blank...

Страница 309: ...Troubleshooting If your server does not operate as expected read this chapter before assuming a failure NOTE For provision against an unexpected failure it is recommended to install NEC ESMPRO to your...

Страница 310: ...ESMPRO Manager on the management PC Check whether any alert is reported on NEC ESMPRO Manager Example LEDS The server includes LEDs to indicate the server states by a variety of colours and display p...

Страница 311: ...instruction simultaneous key entry of Ctrl Alt Delete Immediately after the system is rebooted in response to an OS instruction During hardware initialization following restart of the POST When the PO...

Страница 312: ...e 0230 System RAM Failed at offset 0231 Shadow Ram Failed at offset 0232 Extended RAM Failed at address line Contact your service representative 0250 System battery is dead Replace and run SETUP Conta...

Страница 313: ...tected on CPU socket 1 0B29 Unsupported CPU detected on CPU socket 2 Make sure that the server supports the CPU If you are not sure contact your service representative to request the maintenance 0B42...

Страница 314: ...0B91 BMC update firmware corrupted Turn off the power once and then on again to start the server If the error cannot be corrected contact your service representative 0B92 Internal Use Area of BMC FRU...

Страница 315: ...ted on CPU Slot 2 8150 NVRAM Cleared by Jumper Start SETUP and provide setting again 8151 Password Cleared by Jumper Start SETUP and set password again 8160 Mismatch Processor Type Speed detected on P...

Страница 316: ...ontact your service representative to replace the RAID controller SAS drives were detected but this controller does not support SAS drives Please remove the SAS drives then restart your system Press a...

Страница 317: ...any key to continue or C to load the configuration utility The following VDs are missing xx If you proceed or load the configuration utility these VDs will be removed from your configuration If you wi...

Страница 318: ...ables to ensure all disks are present and reboot Contact your service representative to replace the RAID controller Multibit ECC errors were detected on the controller DIMM on the controller needs rep...

Страница 319: ...ice representative to replace the failed DIMM or mother board 1 3 1 3 Keyboard controller error 1 Check if the keyboard is properly connected 2 Replace the mother board 1 3 3 1 No memory or capacity c...

Страница 320: ...ge send from BMC Example Messages displayed on upper line BIOS message On screen message Description Action XX BIOS Rev YYYY POST in progress XX POST code YYYY BIOS version This is not an error Mem Re...

Страница 321: ...voltage fetal BB Temp1 Alm XX Mother board thermal error occurred XX 09 high voltage fetal XX 07 high voltage warning XX 02 low voltage warning XX 00 low voltage fetal DUMP Request Dump switch is pre...

Страница 322: ...D Controller LSI Embedded MegaRAID is used HDD 4 Fault through HDD 6 Fault are shown on 2 5 inch hard disk model only Sys Fan 1R Alarm Sys Fan 1R alarm occurred Sys Fan 2R Alarm Sys Fan 2R alarm occur...

Страница 323: ...nt plugs Make sure the power breaker for the connected power outlet is on If the power cord is plugged to a UPS make sure the UPS is powered and it outputs power See the manual that comes with the UPS...

Страница 324: ...4 for details Installed DIMMs must be the same speed and must all be registered Is the memory size large The memory check may take a few seconds if the memory size is large Wait for a while Did you pe...

Страница 325: ...t and others with the BIOS SETUP utility of the server Most PCI devices generally do not require any change to the configuration but some boards do require specific settings Refer to the manual that c...

Страница 326: ...eyboard and mouse drivers are installed These drivers are installed along with the OS Some OS s allow you to change the keyboard and mouse settings Refer to manual that comes with your OS to check tha...

Страница 327: ...tion of any SCSI device that is not authorized by Bull is not guaranteed Are SCSI devices properly configured When the server has external SCSI devices connected hard disk drive settings including SCS...

Страница 328: ...RO 1000 has been deactivated from the team Event Type Warning Event Source IANSMiniport Event Category None Event ID 16 Description Team 0 The last adapter has lost link Team network connection has be...

Страница 329: ...ting with the BIOS SETUP utility Menus to check Advanced PCI Configuration Onboard LAN LAN Controller Have the protocol and service already configured Install the distinctive network driver for the se...

Страница 330: ...ction the RAID Controller may be failed Contact your service representative Rebuild fails Is the capacity of the hard disk drive to be rebuilt sufficient The hard disk drive to be rebuilt should have...

Страница 331: ...s appropriate for the RAID controller If the same error persists the RAID controller may be faulty Contact your service representative Are hard disk drives properly installed Install them properly Is...

Страница 332: ...d and battery connector and battery control cable Connect them properly Is the battery connected immediately before The battery may not be detected if it is insufficiently charged If the battery is no...

Страница 333: ...ontroller has an additional battery the following message is registered in the RAID log of the Universal RAID Utility and OS log Event Log or Windows syslog of Linux Source Raidsrv Event ID 508 800001...

Страница 334: ...PlugPlayManager Level Warning Description The service ShellHWDetection may not have unregistered for device event notifications before it was stopped Event ID 7000 Source Service Control Manager Leve...

Страница 335: ...stem account This account is privileged and the provider may cause a security violation if it does not correctly impersonate user requests These events do not affect system operation Ignore these mess...

Страница 336: ...ces administrative tool It is not a problem when operating the system There are some cases that an event log is registered as follows when you install Windows Server 2003 x64 Editions Event Source Ser...

Страница 337: ...contains a binary representation of the record If you use Hardware Management which is provided by Windows Server 2003 R2 above shown event log will be registered The system displays the message below...

Страница 338: ...ter installation of the OS may cause unstable operation Use the ExpressBuilder DVD to update the system See Chapter 6 The system does not restart automatically when a stop error occurs though the syst...

Страница 339: ...ol such as TCP IP and services are properly specified Is the transfer speed correct Open the network property dialog box in the control panel to specify the link speed and duplex value the same as the...

Страница 340: ...r from actual time In this case use NTP server or disable Windows Time Service Problems with the FibreChannel Controller Emulex LPe1150 or LPe11002 When one of the above controllers is used the names...

Страница 341: ...message appears check the error and take the appropriate corrective action according to the message listed in the table below Message Cause This ExpressBuilder version was not designed for this compu...

Страница 342: ...pecified to join the Domain but the system is installed as Workgroup When the setup fails to join the Domain during the installation it will install the system as Workgroup Open System in Control Pane...

Страница 343: ...Parameter File Creator requires to be ran by Microsoft HTML Application host If Parameter File Creator does not start associate the file type with Microsoft HTML Application host as follows 1 Click R...

Страница 344: ...s to appear Is your system Windows XP or later or Windows 2003 or later The Autorun menu is supported by Windows XP Windows 2003 or later If your system runs on Windows 2000 you need to setup IE6 0 be...

Страница 345: ...the server is operating normally may affect the system functionning Restarting the system due to an error may display a message indicating insufficient virtual memory Ignore this message and proceed...

Страница 346: ...al pin a straightened large paper clip will make a substitute into the switch hole to press the DUMP switch DUMP switch Pressing the DUMP switch saves the dump file in the specified directory Memory d...

Страница 347: ...recovery console Note that this method is recommended only for users and administrators who have a thorough knowledge of the recovery console For more information refer to the Online Help For Windows...

Страница 348: ...pressBuilder You may also turn off and then on again to reboot the server System boots up displaying Boot selection menu IMPORTANT An initial selection of the menu is Os installation Os installation s...

Страница 349: ...Troubleshooting 8 41 When you use a local console When you use a remote console 6 Each tool is selected and it starts...

Страница 350: ...information ask your service representative The Off line Maintenance Utility provides the following features IPMI Information Viewer Provides the functions to view the system event log SEL sensor dat...

Страница 351: ...If the update processing is discontinued the system becomes unable after restarting ROM DOS startup FD Creates a support disk for starting the ROM DOS system Test and diagnostics Execute various test...

Страница 352: ...t allows the system administrator to set up the server from the management workstation management PC via the network or the server s COM B serial port IMPORTANT Do not use this feature on any other co...

Страница 353: ...to create a configuration file 3 5 inch floppy disk that includes the communication method between the server and the management PC and various setup parameters Use NEC ESMPRO BMC Configuration or NE...

Страница 354: ...n make sure that no processing is in progress FORCED SHUTDOWN Use this function when an OS command does not shut down the server the POWER switch does not turn off the server or resetting does not wor...

Страница 355: ...optional devices or the server or malfunctions of the server resulted from installation by the user Bull recommends you ask your service representative for installing or removing any optional devices...

Страница 356: ...the lithium battery Disconnect the power plug before working with the server CAUTION Observe the following instructions to use the server safely Failure to follow these instructions may cause a fire p...

Страница 357: ...y Select a suitable work space Work with the server on the anti static or concrete floor When you work with the server on a carpet where static electricity is likely to be generated make sure to take...

Страница 358: ...ves and power supply units CAUTION Observe the following instructions to use the server safely Failure to follow these instructions may cause a fire personal injury or property damage See pages 1 3 to...

Страница 359: ...unlock the server To place the server in the rack push it back into the rack while pushing the right and left release levers blue forward or rearward Release lever blue IMPORTANT Be very careful not t...

Страница 360: ...dded MegaRAID or optional RAID Controller LSI Logic SAS CTRL 8708EM2 supports serial ATA SATA interface Up to three hard disk drives mounted on the dedicated 3 5 inch width tray can be installed IMPOR...

Страница 361: ...15000 rpm SAS 450GB 15000 rpm SAS The hard disk drive bays are connected to the Mini SAS connector on the mother board To use the hard disk drives in a RAID System refer to When using the Onboard RAI...

Страница 362: ...0rpm SAS 146 5GB 10000rpm SAS 300GB 10000rpm SAS 36 3GB 15000rpm SAS 73 2GB 15000rpm SAS 146 5GB 15000rpm SAS The hard disk drive bays are connected to the Internal RAID Controller When using the Inte...

Страница 363: ...Do not press the POWER switch during the installation or removal of the hard disk drive if your server is running 3 5 inch Hard Disk Drive 1 See the section Preparing for Installation and Removal desc...

Страница 364: ...rt it into the chassis IMPORTANT Do not push on the handle until the handle begins to close by itself Carefully hold the hard disk drive with both hands Do not press the POWER switch during the instal...

Страница 365: ...er to check if it is firmly secured 8 Power on the server and run SETUP utility Select Boot menu to set the boot priority When you have installed an additional hard disk drive the boot priority stored...

Страница 366: ...rd disk drive The server has six slots Fill the vacant slots with hard disk drives from the lower port number 3 Remove the dummy tray or drive carrier if installed IMPORTANT Keep the dummy tray for fu...

Страница 367: ...to the frame when having inserted the hard disk drive Be careful not to get your finger caught between the handle and tray NOTE The hard disk drive bay is located close to the POWER switch Pay attent...

Страница 368: ...e hard disk drive 9 Power on the server and run the SETUP utility Select the Boot menu to set the boot priority When you have installed an additional hard disk drive the boot priority stored in the BI...

Страница 369: ...oval DISK LED DISK LED 3 5 inch hard disk drive 2 5 inch hard disk drive 3 5 inch Hard Disk Drive 1 See the section Preparing for Installation and Removal described earlier 2 Unlock the front bezel wi...

Страница 370: ...the handle and hard disk drive and pull out the hard disk drive 5 If using the server with the hard disk drive removed install the dummy tray in the vacant slot to ensure the cooling efficiency 6 Inst...

Страница 371: ...ver to unlock and open the handle IMPORTANT Do not press the POWER switch during the installation or removal of the hard disk drive if your server is running 4 Firmly hold the handle and hard disk dri...

Страница 372: ...DISK LED lights amber Remove and install the hard disk drive again to restart auto rebuild If the RAID System management utility is installed it may display or act as follows Displays Rebuild was canc...

Страница 373: ...the unlikely event one of the power supply unit fails Power supply slot standard Power supply slot option Installation Take the following steps to install a power supply unit 1 See the section Prepari...

Страница 374: ...3 Insert the power supply unit IMPORTANT Do not touch the terminals of the power supply unit Contact terminals 4 Grasp the handle and firmly push the power supply The power supply unit is locked when...

Страница 375: ...nit Standard Power cord Power supply unit Option Power cord 6 Power on the server The AC POWER LEDs go on AC POWER LED Option Standard 7 Confirm by the STATUS LED or on the POST screen that there are...

Страница 376: ...ord from the failed power supply unit 4 Hold the handle of the failing power supply unit 5 While pressing the lever pull the power supply unit to remove if from the chassis Lever 6 If you do not insta...

Страница 377: ...the top cover toward the rear of the server while pressing the lock button on the cover 4 Lift off the top cover from the server Installation When installing the top cover confirm that the tab of the...

Страница 378: ...uch the metal frame of the server to discharge static electricity from your body before handling the DIMM Do not touch the DIMM terminals or on board parts by a bare hand or place the DIMM directly on...

Страница 379: ...DIMMs starting from the smallest slot number 2 CPU configuration Alternately install DIMMs starting from the smallest slot number of each CPU Install DIMMs starting from the largest capacity and from...

Страница 380: ...om the smallest socket number NOTE Memory mirroring and LockStep x8 SDDC features are optional Contact your service representative for details For configuration see Using the Memory RAS Features descr...

Страница 381: ...The memory clock is stationary for each CPU Condition An additional 8 GB memory board is installed and each CPU has four or more DIMMs installed Example Operates at 800MHz Operates at 1066MHz Memory R...

Страница 382: ...7 Holding the DIMM by the edges remove it from its anti static package 8 Position the DIMM above the socket Align the small notch at the bottom edge of the DIMM with the key in the socket NOTE Make s...

Страница 383: ...n to verify that the installed DIMM shows the status Normal See Chapter 4 or details 14 Select Yes for Reset Configuration Data on the Advanced menu This setting is required to change the hardware con...

Страница 384: ...y the edges lift it away from the socket and store it in an anti static package 6 Reinstall all parts removed in Steps 3 to 7 See installation procedures for detail explanations 7 Power on the server...

Страница 385: ...tive for details To use x4 SDDC ECC memory feature an additional 2 GB 4 GB 8 GB memory board is required The factory installed two 1 GB DIMMs and an additional 1 GB memory board is unavailable for x4...

Страница 386: ...et 1 Mirror set 4 Mirror set 2 Memory controller Example In 2 CPU configuration CH0 CH1 Data 1 Data 1 Data 2 Data 2 Data 3 Data 3 Data 4 Data 4 NOTE The operating system only recognizes a half of the...

Страница 387: ...9 33 Install memory devices in the following order 1 CPU configuration 2 CPU configuration 2 4 2 4 2 3 1 1 2 3 1 1 Mother board The following mirroring cannot be configured Memory mirroring within a s...

Страница 388: ...abling the memory mirroring In this case execute Load Setup Defaults to cancel the memory mirroring configuration Procedure 1 Note down the settings in BIOS SETUP 2 Press F2 during POST to run the BIO...

Страница 389: ...re multiplexed and operated in parallel to enable x8 SDDC x8 Single Device Data Correction With this feature a single device can detect and correct one to eight bit error IMPORTANT The LockStep featur...

Страница 390: ...opriately in the menu selected as shown below save the settings and exit from SETUP Select Advanced Memory Configuration submenu Memory RAS Feature Lock Step Install memory devices in the following or...

Страница 391: ...is disabled In this case execute Load Setup Defaults to cancel the LockStep configuration 1 Note down the settings in the BIOS SETUP utility 2 Press F2 during POST to run BIOS SETUP utility 3 Select...

Страница 392: ...section Anti static Measures described earlier Do not operate the system until confirming that the additionally installed CPU is operating normally Make sure to use the CPU authorized by Bull Installi...

Страница 393: ...tallation and Removal described earlier 2 Pull out the server from the rack 3 Remove the top cover 4 Remove the processor duct from the chassis IMPORTANT Make sure not to damage the internal cables 5...

Страница 394: ...and away from the socket 8 Lift the load plate IMPORTANT Do not touch the socket contacts 9 Remove the protective socket cover from the load plate IMPORTANT Do not discard the protective socket cover...

Страница 395: ...re below Notch Pin Marker Key Pin Marker NOTES Align notches with the socket Lower the processor straight down without tilting or sliding it in the socket IMPORTANT Hold the processor only at the edge...

Страница 396: ...PU and fix the heat sink with four screws Make sure that the screws align with the screw holes If not the screws may damage the mother board Notches NOTE Be aware of how the heat sink is oriented see...

Страница 397: ...auses the heat sink not to be flush The CPU is not positioned correctly All screws are not completely tightened Do not move the secured heat sink 14 Reinstall the processor duct NOTES Check to see tha...

Страница 398: ...ssor Settings on the Main menu to Enable 17 Verify that POST does not disply error messages If POST displays an error message note down the message and see the POST error messages listed in Chapter 8...

Страница 399: ...be apart from the CPU Removing the heat sink with it adhering to the CPU may cause the CPU and or socket to be defective Do the following procedure if a CPU is removed or replaced 1 Start SETUP and s...

Страница 400: ...t touch the PCI board terminals or on board parts by a bare hand or place the PCI board directly on the desk For static notes see the section Anti static Measures Some restrictions are imposed on the...

Страница 401: ...PCI boards Riser card slot Dedicated to full height PCI boards Slot for RAID Controller REAR Mother board FRONT PCI board slot Connector pins for riser card slot Riser card low profile side PCI board...

Страница 402: ...bove depending on the OS or on the RAID System BIOS Utility Check the slot location of the PCI device using the PCI bus number device number and function number shown in the table below Bus number Dev...

Страница 403: ...ions NOTES Each riser card supports low profile or full height PCI boards Before installing a PCI board check the type of the PCI board When installing a PCI board check that the card connector matche...

Страница 404: ...lot cover Additional slot cover Low Profile side Additional slot cover Full height side 6 Install the PCI board on the riser card Align the PCI board terminal section with the riser card slot and firm...

Страница 405: ...ss force to a PCI board or riser card Doing so may damage the card NOTES Confirm that the end of the PCI board bracket is inserted in the frame slot of the riser card Some PCI boards have terminal sec...

Страница 406: ...hen inserting it into the slot 9 Install the components you removed previously 10 Verify that POST does not display error messages If POST displays an error message take a note on the message and see...

Страница 407: ...ponents 5 Remove the two screws securing the bracket then remove the bracket Screws 6 Remove the PCI bracket from the RAID Controller Screws PCI bracket 7 Install the RAID Controller to the bracket th...

Страница 408: ...9 54 Upgrading Your Server Screws...

Страница 409: ...RAID Controller in the server chassis and secure it with the screws used for securing the bracket Screws 9 Install the components you have removed Removing RAID Controller Remove the RAID Controller i...

Страница 410: ...arlier 2 Pull out the server from the rack 3 Remove the top cover 4 Remove the riser card IMPORTANT Carefully remove the riser card taking care not to touch the other components 5 Disconnect the cable...

Страница 411: ...Upgrading Your Server 9 57 Connector board Screw 8 Secure the RAID Controller to the server chassis 9 Disconnect the fan cables four cables at right side viewed from the front...

Страница 412: ...r Server 10 Remove the three screws securing the battery bracket then remove the battery bracket Screws 11 Connect the cable to the additional battery Be aware of the face of the connector according t...

Страница 413: ...the battery bracket with three screws Use screws that come with the additional battery Screws Install the additional battery in the portion enclosed with dashed line 13 Secure the battery bracket to...

Страница 414: ...9 60 Upgrading Your Server 14 Route the cable as shown in the figure below When connecting to the Onboard RAID Controller...

Страница 415: ...Upgrading Your Server 9 61 When connecting to the optional RAID controller installed in the low profile slot...

Страница 416: ...9 62 Upgrading Your Server When connecting to the optional RAID controller installed in the full height slot...

Страница 417: ...Your Server 9 63 15 Connect the cable to the connector board installed on the RAID Controller Be aware of the face of the connector according to the figure below 16 Install the components you removed...

Страница 418: ...oval described earlier 2 Pull out the server from the rack 3 Remove the top cover 4 Remove the riser card IMPORTANT Carefully remove the riser card taking care not to touch the other components 5 Disc...

Страница 419: ...connector board provided with the additional battery to the RAID Controller Connector board Screw 8 Secure the RAID Controller to the server chassis 9 Remove the three screws from the battery bracket...

Страница 420: ...emove the additional battery by pushing the claw in the direction of arrow mark then disconnect the cable Claw Cable 11 Connect the cable to the additional battery Be aware of the face of the connecto...

Страница 421: ...cable through the hole on the battery bracket then install the battery on the battery bracket Cable hole 13 Connect the cable to the base board then secure the base board to the additional battery wi...

Страница 422: ...9 68 Upgrading Your Server 14 Secure the battery bracket on which the additional battery is installed to the server chassis with screws Screws 15 Route the cable as shown in the figure below...

Страница 423: ...Your Server 9 69 16 Connect the cable to the connector board installed on the RAID Controller Be aware of the face of the connector according to the figure below 17 Install the components you removed...

Страница 424: ...d earlier 2 Pull out the server from the rack 3 Remove the top cover 4 Remove the riser card IMPORTANT Carefully remove the riser card taking care not to touch the other components 5 Disconnect the ca...

Страница 425: ...71 7 Remove the three screws from the battery bracket then remove the battery bracket Screws 8 Remove the additional battery by pushing the claw in the direction of arrow as shown below then disconne...

Страница 426: ...9 Connect the cable to the additional battery Be aware of the face of the connector according to the figure below 10 Install the connector board provided with the additional battery to the RAID Contro...

Страница 427: ...er 9 73 11 Connect the cable to the additional battery Be aware of the face of the connector according to the figure below 12 Install the battery to the battery bracket and secure the base board with...

Страница 428: ...ecure the battery bracket on which the additional battery is installed to the server chassis with screws Screw 14 Route the cable as shown in the figure below When connecting to the RAID controller in...

Страница 429: ...o the connector board installed on the RAID Controller Be aware of the face of the connector according to the figure below 16 Install the components you removed previously Removing the Additional Batt...

Страница 430: ...uable data make sure to make a backup copy of the data to another hard disk drive before installing the RAID Controller and configuring the RAID System More than one hard disk drive is required to con...

Страница 431: ...ystem reconnect the hard disk drive interface cable on the mother board At the factory the interface cable is connected to the SATA HDD connector on the mother board Refer to the manual coming with th...

Страница 432: ...d specification Some RAID Controller has LED cable connector to be used for indication of disk access However this server is not equipped with LED cable connector To use internal hard disk drives in a...

Страница 433: ...ild a RAID System use the Internal RAID Controller The hard disk drive bays are connected to the Internal RAID Controller at the factory Standard Configuration Internal RAID Controller Use WebBIOS to...

Страница 434: ...OS setup Use Express Setup even when not installing an operating system Start Express Setup select OS Selection Others The installer automatically performs all the procedures for RAID System configura...

Страница 435: ...ll You cannot install the floppy disk drive if an additional battery for the RAID controller is installed Floppy disk drive bay Installation Take the following steps to install an optional floppy disk...

Страница 436: ...5 Slide the stay for bracket to the direction of the arrow marks shown in the figure below and remove the stay 6 Remove the floppy disk drive bracket by sliding it to the direction of the arrow marks...

Страница 437: ...the order shown by the arrow marks in the figure below Engage the screw holes of the floppy disk drive with the claws on the server chassis and fix the floppy disk drive 8 Align the claw of the stay w...

Страница 438: ...n the figure below 10 Connect the cable to the USB FDD connector on the mother board USB FDD connector FRONT REAR Mother board 11 Install the components you removed previously Removal Remove the flopp...

Страница 439: ...SK DRIVE You may replace the factory installed optical disk drive with an optional DVD drive IMPORTANT Be sure to use the DVD drive authorized by Bull 2 5 inch Disk Model Optical disk drive bay 3 5 in...

Страница 440: ...nstallation and Removal described earlier 2 Pull out the server from the rack 3 Remove the top cover 4 Remove the cable while holding both ends of the cable fixing bracket of the optical disk drive 5...

Страница 441: ...erver 9 87 6 Remove the three screws securing the optical disk drive then remove the optical disk drive Screws 7 Remove the optical disk drive bracket to the direction of the arrow marks as shown in t...

Страница 442: ...Align the screw holes on the optional DVD drive with claws on the optical disk drive bracket A Claws Screw holes 9 Secure the drive with the three screws that were used for securing the optical disk d...

Страница 443: ...onal DVD drive mounted to the server then tighten the thumb screw to secure it Thumb screw 11 Connect the SATA cable to the optional DVD drive Then fix the SATA cable with the cable fixing bracket Cab...

Страница 444: ...ve the cable while holding both ends of the cable fixing bracket 5 Remove the screw from the optical disk drive bracket then remove the optical disk drive bracket Move the bracket to the left as viewe...

Страница 445: ...he slot then move the drive to the right 8 Secure the optional DVD drive with the optical disk drive bracket Then tighten the screw Cable fixing bracket Screw Optical disk drive bracket 9 Connect the...

Страница 446: ...9 92 Upgrading Your Server This page is intentionally left blank...

Страница 447: ...450 GB x3 Hot plug hard disk drive Supported Optical disk drive Standard DVD ROM drive x1 DVD x3 to x8 speed CD x10 to x24 speed Option DVD Super Multi x1 to be replaced with DVD ROM drive Auxiliary...

Страница 448: ...nt power supply Supported option Redundant fan Supported standard Front bezel Inner rail Protruding portion excluded 428 width x 722 depth x 44 height External dimensions mm Front bezel Inner rail Pro...

Страница 449: ...al FDD 2 mode or 3 5 inch external FDD 2 mode Hard disk drive bay 6 slots Additional bay 3 5 inch floppy disk drive bay None Full height Standard 1 slot PCI Express 2 0 x16 x 1 slot When option riser...

Страница 450: ...pth x 44 height Weight Max 16 kg 21 kg Power supply AC 100V 10 AC 200V 10 50 60Hz 1Hz Temperature 10 to 35 C operating 10 to 55 C non operating storage Environmental requirements Humidity 20 to 80 RH...

Страница 451: ...ch floppy disks You can use the following two types of 3 5 inch floppy disks 2HD floppy disk double sided high density track type Stores data of 1 44MB 2DD floppy disk double sided double density trac...

Страница 452: ...switch provided on its back Disk format To write data into a floppy disk the floppy disk must be formatted Formatting is to initialize the floppy disk and make it available for the system environment...

Страница 453: ...le data or programs into the cartridge tape you should save them into two cartridge tapes to make the primary and secondary tapes This enables you to restore your data from one tape when the other mak...

Страница 454: ...B 4 Other Precautions NOTE The keyboard functions depend on the software Refer to the manual that comes with the software for details...

Страница 455: ...he mouse on a dusty or dirty desk disturbs smooth movement or normal operation of the mouse When your mouse movement seems dull clean your mouse See Chapter 7 Mouse operation includes Click Double cli...

Страница 456: ......

Страница 457: ...IRQ Peripheral Device Controller IRQ Peripheral Device Controller 0 System timer 12 SM Bus 1 13 Numeric processor 2 14 Primary IDE 3 COM2 serial port 15 4 COM1 serial port 16 VGA LAN1 5 PCI 17 LAN2 S...

Страница 458: ...C 2 IRQ This page is intentionally left blank...

Страница 459: ...ID Controller LSI Logic SAS CTRL 8708EM2 RAID Controller 128MB RAID0 1 LSI Logic SAS CTRL 8708EM2 RAID Controller 128MB RAID0 1 5 6 LSI Logic SAS CTRL 8708EM2 RAID Controller 256MB RAID0 1 5 6 Onboard...

Страница 460: ...sk drive if necessary About the System Partition Size The system partition size can be calculated from the following formula When the system is Windows Server 2008 64 bit x64 Edition Required partitio...

Страница 461: ...information memory dump The paging file with initial size large enough to store the dump file in the boot drive is required Correct debug information might not be able to be collected due to virtual...

Страница 462: ...ndows Server 2008 OEM Disk for EXPRESSBUILDER You can create Windows Vista OEM Disk for EXPRESSBUILDER with the following two procedures Create from the menu which appears when running NovaScale R440...

Страница 463: ...ow the steps below 1 Prepare one 3 5 inch floppy disk 2 Start the Operating System 3 Insert the ExpressBuilder DVD into the optical disk drive of the server The Menu will appear 4 Insert the floppy di...

Страница 464: ...Server 2008 DVD ROM into your DVD ROM drive NOTE When You use Onboard RAID controller LSI Embedded MegaRAID Windows Server 2008 OEM Disk for EXPRESSBUILDER is necessary 3 Restart the system To restar...

Страница 465: ...bit x64 Edition Insert the Windows Server 2008 x64 OEM Disk for EXPRESSBUILDER into the floppy disk drive and press Browse Windows Server 2008 32 bit x86 Edition Insert the Windows Server 2008 OEM Di...

Страница 466: ...will see only possible editions that have been determined by Windows based on the key you entered in step 9 NOTE The Windows versions listed on the screen vary depending on the Windows Server 2008 DVD...

Страница 467: ...l be created and then click Drive Option IMPORTANT If the partition has already been created go to step 16 14 Click New enter a partition size and then click Apply 15 Select the partition created in s...

Страница 468: ...l 17 Log on to the system The steps vary depending on the edition you selected in step 7 If you have selected a full installation 1 After a full installation of Windows Server 2008 is completed the fo...

Страница 469: ...user information If you have selected a Server Core installation 1 After a Server Core installation of Windows Server 2008 is completed press Ctrl Alt Del 2 Select Other User 3 Log on to the system as...

Страница 470: ...g on you will be prompted to change the password Click OK 5 Change the password and then click the button NOTE The Windows Server 2008 password must combine uppercase letters lowercase letters and num...

Страница 471: ...s Server 2008 you may need to update BIOS To check if your system needs a BIOS update go to www bull com 2 Insert the Windows Server 2008 DVD ROM into your DVD ROM drive 3 Restart the system To restar...

Страница 472: ...ur product key and then click Next 7 Select the edition of the Windows operating system that you purchased Select I have selected the edition of Windows that I purchased and then click Next You will s...

Страница 473: ...nding on the Windows Server 2008 DVD ROM you are using 8 Read the license terms carefully If you agree select I accept the license terms and then click Next 9 Select the type of installation you want...

Страница 474: ...s is displayed Select the following driver and then click OK Go to Step 11 LSI Logic MegaRAID SAS 8708EM2 RAID Controller If the Internal RAID Controller or LSI Logic SAS CTRL 8708EM2 is not used Go t...

Страница 475: ...el 16 Log on to the system The steps vary depending on the edition you selected in step 7 If you have selected a full installation 1 After a full installation of Windows Server 2008 is completed the f...

Страница 476: ...ows Server 2008 3 On the Initial Configuration Tasks window enter user information If you have selected a Server Core installation 1 After a Server Core installation of Windows Server 2008 is complete...

Страница 477: ...erver 2008 D 19 2 Select Other User 3 Log on to the system as an administrator You need not enter your password in this dialog box Click the button 4 Before you log on you will be prompted to change t...

Страница 478: ...r 2008 Step By Step Guide After installations is completed be sure to execute the tasks described in Setup of Device Driver Normally Install in Server and Updating the System of this chapter Updating...

Страница 479: ...yed click Setup Windows and click Update the system NOTE Right clicking on the Menu produces the same outcome If you have selected a Server Core installation 1 Execute the following command line from...

Страница 480: ...D 22 Installing Windows Server 2008 5 When the following message appears click No 6 When the following message appears click Yes to restart the system The system has been updated...

Страница 481: ...ll installation 1 Remove a team of network adapters NOTE Before you remove note down the current settings e g IP addresses of the standard and optional adapters teamed for network redundancy Configure...

Страница 482: ...r 009 win winnt ws2008 ma21 apps prosetdx vista32 dxsetup exe 3 In Intel R Network Connections InstallShield Wizard click Next 4 Select Remove and click Next 5 Click Remove Uninstallation starts autom...

Страница 483: ...ional network boards are available Intel Pro 1000 MF Pro 1000 MT Pro 1000 GT Pro1000 PT To use the Intel Pro 1000 PT Adapter see Using Intel Pro 1000 PT Adapter after System Update in the previous pag...

Страница 484: ...o modify the team Click Settings tab and click Modify Team button 9 Refer to the following procedure to set the team member adapter priority status Set Primary Point the adapter and click Set Primary...

Страница 485: ...Dual Port Server Network Connection 2 to open the adapter Properties 3 Click Power Management tab and change setting in Wake On LAN according to the following list Setting item Default setting Change...

Страница 486: ...ccessories and click Windows Explorer 3 Run Install bat in the following directory Windows Server 2008 64 bit x64 Edition 009 win winnt ws2008x64 video Windows Server 2008 32 bit x86 Edition 009 win w...

Страница 487: ...tware Logic MegaRAID SAS 8880EM2 RAID Controller Wizard appears select Browse my computer for driver software 5 Select Let me pick from a list of device drivers on my computer 6 Click Have Disk 7 Inse...

Страница 488: ...e you can use Windows Server 2008 Windows activation process is as follows For a server running a full installation 1 Go to the Start menu and in the Run dialog box type slui and press Enter IMPORTANT...

Страница 489: ...Installing Windows Server 2008 D 31 2 In the following screen click Type a different product key 3 Type the product key shown on your COA label and click Next...

Страница 490: ...D 32 Installing Windows Server 2008 4 Activate Windows The Windows activation is complete...

Страница 491: ...n your system Click to exit 2 Type slmgr ipk PID and press Enter PID is your product key on the COA label 3 Type slmgr dti to obtain an installation ID for Windows activation and press Enter 4 See sys...

Страница 492: ...on In Windows Server 2008 system the PAE option can be set by using Bcdedit exe The setting procedure is as follows 1 Click Run on Start menu 2 Type cmd exe in the Open box to start command prompt 3 E...

Страница 493: ...Installing Windows Server 2008 D 35 SETTING FOR SOLVING PROBLEMS Set for collecting memory dump using the procedure described in Chapter 5...

Страница 494: ......

Страница 495: ...talling with the OEM Disk for Mass storage device and Installing Optional Mass Storage Driver of Parameter File Creator in Chapter 6 Controllers supporting installation of OS with Express Setup Intern...

Страница 496: ...e system in the Autorun Menu Re installing to the Hard Disk Drive which has been upgraded to Dynamic Disk If you want to leave the existing partition when installing the system on the hard disk drive...

Страница 497: ...nsufficient so set an enough size of the paging file with the entire system Regardless of the size of the mounted memory or the Write debugging information type of memory dump the maximum size of the...

Страница 498: ...Installation ExpressBuilder DVD Microsoft Windows Server 2003 R2 Standard x64 Edition CD ROM Microsoft Windows Server 2003 R2 Enterprise x64 Edition CD ROM Microsoft Windows Server 2003 x64 Editions S...

Страница 499: ...on OEM Disk for EXPRESSBUILDER use this procedure If Windows Server 2003 can be operated on NovaScale R440 E2 Server you can use the other procedure described later Follow the steps below 1 Prepare on...

Страница 500: ...w the steps below 1 Prepare one 3 5 inch floppy disk 2 Start the Operating System 3 Insert the ExpressBuilder DVD into the optical disk drive of the server The Menu will appear 4 Insert the floppy dis...

Страница 501: ...displayed A screen with a solid blue background is displayed IMPORTANT There is no visible indication on screen when F6 has been pressed 5 When the following message is displayed press S Setup could n...

Страница 502: ...s Windows 64 bit and press Enter IMPORTANT If the following message is displayed when you use the ADAPTEC 29320ALP or Adaptec ASC 29320LPE SCSI controller press S The driver you provided seems to be n...

Страница 503: ...soft Windows Server 2003 R2 x64 Edition DISC 2 In this case note that the Windows Setup screen is not displayed 14 Insert Microsoft Windows Server 2003 R2 x64 Edition DISC 2 CD ROM into the optical di...

Страница 504: ...again when Windows Server 2003 x64 Editions CD ROM where ServicePack 2 is included is used and it is installed If you install Windows Server 2003 x64 Editions CD ROM which contains Service Pack 2 you...

Страница 505: ...essBuilder DVD into the optical disk drive of the server 3 Click Start menu and Run and then execute the following command When Windows Server 2003 x64 Editions is used 009 win winnt w2k3amd qfe enu k...

Страница 506: ...e pack 2 again 1 Log on to the system with the account that has administrative privilege e g administrator 2 Insert the ExpressBuilder DVD into the optical disk drive of server The Autorun Menu will b...

Страница 507: ...s and then go to Step 6 When you don t apply Service Pack Click No and then go to Step 8 6 When the following message appears click Yes 7 When the following message appears select a Service Pack and c...

Страница 508: ...w tab and then click OK Hide extensions for know file type Hide protected operating system files Recommended When the message You have chosen to display protected operating system files is displayed c...

Страница 509: ...back test packet transmission test and so on Setup of teaming Configuring several network adapters as one team provides the server a tolerant environment on any trouble and enhances throughput betwee...

Страница 510: ...cified for HUB 4 Click OK When PROSet is installed 1 Open the Device Manager 2 Double click Network Adapter Name in the list 3 Click the Link Speed and specify the Speed Duplex value the same as the v...

Страница 511: ...and click Next 5 Select the Search for the best driver in these locations radio button and check off the Search removable media floppy CD ROM check box 6 Check the Include this location in the search...

Страница 512: ...Team name from Device manager Network adapters to modify the team Click Settings tab and click Modify Team button 9 Refer to the following procedure to set the team member adapter priority status Set...

Страница 513: ...on Intel R 82576 Gigabit Dual Port Server Network Connection 2 to open the adapter Properties 3 Click Power Management tab and change setting in Wake On LAN according to the following list Setting ite...

Страница 514: ...ower Management tab and change setting in Wake On LAN according to the following list Setting item Default setting Change setting Wake On Directed Packet ON ON Wake On Magic Packet ON ON Wake on Magic...

Страница 515: ...ow the message to continue the installation If the dialog message Digital Signature could not been found appears select Yes to continue 5 Remove the ExpressBuilder DVD from the optical disk drive rest...

Страница 516: ...trative Tools Computer Management 2 Double click the RAID Controller which Device Manager lists as Other device 3 Click Update Driver 4 When the Update Device Driver Wizard appears select No not this...

Страница 517: ...ows Server 2003 x64 Editions must be activated before you can use Windows Server 2003 x64 Editions Windows activation process is as follows 1 Click Run on Start menu Type as follows in the Open box an...

Страница 518: ...erver 2003 X64 Editions The following screen is displayed 3 Process Windows activation according to the following message SETTING FOR SOLVING PROBLEMS Set for collecting memory dump using the procedur...

Страница 519: ...ing with the OEM Disk for Mass storage device and Installing Optional Mass Storage Driver of Parameter File Creator in Chapter 6 Controllers supporting installation of OS with Express Setup Internal R...

Страница 520: ...nu Re installing to the Hard Disk which has been upgraded to Dynamic Disk If you want to leave the existing partition when installing the system on the hard disk upgraded to Dynamic Disk note the foll...

Страница 521: ...ndows Server 2003 R2 backup user data referring Windows Server 2003 Clean Installation and reinstall Windows Server 2003 R2 NOTE in place upgrade is to perform overwrite upgrade from Windows Server 20...

Страница 522: ...nt so set an enough size of the paging file with the entire system The maximum paging file size which can be set on one partition is 4095MB If the above paging file size exceeds 4095MB specify 4095MB...

Страница 523: ...ows Server 2003 Standard Edition CD ROM Microsoft Windows Server 2003 Enterprise Edition CD ROM Microsoft Windows Server 2003 R2 Standard Edition CD ROM Microsoft Windows Server 2003 R2 Enterprise Edi...

Страница 524: ...R use this procedure If Windows Server 2003 or Windows can be operated on NovaScale R440 E2 Server you can use the other procedure described later Follow the steps below 1 Prepare one 3 5 inch floppy...

Страница 525: ...elow 1 Prepare one 3 5 inch floppy disk 2 Start the Operating System 3 Insert the ExpressBuilder DVD into the optical disk drive of the server The Menu will appear 4 Insert the floppy disk into the fl...

Страница 526: ...solid blue background is displayed IMPORTANT There is no visible indication on screen when F6 has been pressed 5 When the following message is displayed press S Setup could not determine the type of o...

Страница 527: ...ovided seems to be newer than the Windows default driver Windows already has a driver that you can use for Adaptec Ultra320 SCSI Cards Windows 32 bit Unless the device manufacturer prefers that you us...

Страница 528: ...n to the system IMPORTANT In this case the Windows Setup screen may not be displayed Be sure to install Microsoft Windows Server 2003 R2 DISC 2 according to the following procedures You can install Mi...

Страница 529: ...figuration Recovered the system using recovery process The system update brings the correction program provided by Microsoft to be applied to reinforce the system security The system update is recomme...

Страница 530: ...en the English version of Windows Server 2003 R2 is used 009 win winnt dotnet qfe enu kb921411 exe When the Simplified Chinese version of Windows Server 2003 R2 is used 009 win winnt dotnet qfe chs kb...

Страница 531: ...into the optical disk drive of server The Autorun Menu will be displayed 3 Left click on Setup Windows and then click Update the system NOTE Right clicking on the Autorun Menu produces the same outcom...

Страница 532: ...ver 2003 7 When the following message appears select a Service Pack and click Open and then according to a message please apply it 8 When the following message appears click Yes to restart the system...

Страница 533: ...ab and then click OK Hide extensions for know file type Hide protected operating system files Recommended When the message You have chosen to display protected operating system files is displayed clic...

Страница 534: ...e throughput between the switches PROSet is necessary to utilize these features Follow the procedure below to install PROSet 1 Insert the ExpressBuilder DVD into the optical disk drive If the autorun...

Страница 535: ...ial up Connection NOTE We recommend you to add Network Monitor at Adding Services Network Monitor can monitor the frame or the packet that the computer installing Network Monitor sends or receives Thi...

Страница 536: ...cording to the following list Setting item Default setting Change setting Allow the computer to turn off this device to save power ON ON Allow this device to bring the computer out of standby OFF ON 4...

Страница 537: ...nagement tab and change setting in Wake On LAN according to the following list Setting item Default setting Change setting Wake On Directed Packet ON ON Wake On Magic Packet ON ON Wake on Magic Packet...

Страница 538: ...ll bat in the following directory 009 win winnt dotnet video install bat 4 Follow the message to continue the installation If the dialog message Digital Signature could not been found appears select Y...

Страница 539: ...e Tools Computer Management 2 Double click the RAID Controller which Device Manager lists as Other device 3 Click Update Driver 4 When the Update Device Driver Wizard appears select No not this time a...

Страница 540: ...ted before you can use Windows Server 2003 Windows activation process is as follows NOTE When you use Windows Server 2003 R2 activation process is not needed 1 Click Run on Start menu Type as follows...

Страница 541: ...Installing Windows Server 2003 F 23 The following screen is displayed 3 Process Windows activation according to the following message...

Страница 542: ...el double click System System Properties dialog box will be shown 3 Click the Advanced tab and then click Settings under Setup and Recovery 4 Under System Setup click Edit to open Boot ini 5 Add PAE t...

Страница 543: ...run menu appears close the menu 3 Copy the below files of EXPRESSBUILDER to a hard disk by using Explorer root folder 009 copy version xml ar_menu copy this sub folder doc copy this sub folder win cop...

Страница 544: ...G 2 Using a Client Computer with a CD Drive This page is intentionally left blank...

Страница 545: ...No Date Installed CPU1 DIMM6 Size Serial No Date Installed CPU2 DIMM1 Size Serial No Date Installed CPU2 DIMM2 Size Serial No Date Installed CPU2 DIMM3 Size Serial No Date Installed CPU2 DIMM4 Size Se...

Страница 546: ...o Date Installed Printer Model name Serial No Manufacturer Date Installed Additional Cabinet for Disk Model name Serial No Date Installed External Peripheral Device 1 Model name Serial No Manufacturer...

Страница 547: ...Table H 3 Software Firmware version OS Name Version Application of RUR media Apply Name Version File system FAT HPFS NTFS Others Bundled software installed Licensed software installed Application run...

Страница 548: ...H 4 Product Configuration Record Table This page is intentionally left blank...

Страница 549: ...M __________________________________________________________ DATE _____________ SOCIETE _____________________________________________________________________________ ADRESSE __________________________...

Страница 550: ...___________________________________ DATE _____________ SOCIETE _____________________________________________________________________________ ADRESSE ___________________________________________________...

Страница 551: ......

Страница 552: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 46FB 00...

Отзывы: