Configuring Your Server 4-47
Patrol Read
The patrol read performs the read & verify test in the entire area of HDDs. It can be performed for all HDDs assigned as virtual
disks and hot-spares.
The Patrol Read allows subsequent defects of HDDs to be detected and repaired.
For HDDs configured as redundant virtual disks or those assigned as hot-spares, error sectors detected during Patrol Read can
be repaired.
IMPORTANT:
Note the following for the patrol read feature:
For the Internal RAID Controller, the Patrol Read feature is factory-set to "Enabled". For the
external SAS RAID controller, the Patrol Read feature is either enabled or disabled depending
on the firmware.
To change the Patrol Read settings, use the Universal RAID Utility.
If the system is restarted while running Patrol Read, Patrol Read resumes from the point where
it was stopped.
Consistency Check
The Consistency Check is used to check the consistency among virtual drives. It is available for redundant virtual drives except
for RAID0. It is also available for the hot spares.
Consistency Check can be performed through WebBIOS or the Universal RAID Utility.
Consistency Check performs not only consistency check but also repairs of defective sectors. Accordingly, it can be used as a
preventive maintenance.
IMPORTANT:
Note the following for the Consistency Check feature:
During the Consistency Check process, the processing rate is decreased due to the high load.
If the system is restarted, the Consistency Check is aborted. However, the Consistency Check
resumes after restart.
To schedule the execution of the Consistency Check feature, use WebBIOS, not the Universal
RAID Utility.
Содержание NovaScale R440 E2
Страница 1: ...NovaScale R440 E2 User s Guide NOVASCALE REFERENCE 86 A1 46FB 00...
Страница 2: ......
Страница 32: ...1 16 Notes on Using Your Server...
Страница 70: ...2 38 General Description...
Страница 94: ...3 24 Setting Up Your Server This page is intentionally left blank...
Страница 147: ...Configuring Your Server 4 53 Property of Physical Device in the Universal RAID Utility...
Страница 187: ...Configuring Your Server 4 93 6 Click Home at the lower left of the screen to go back to the WebBIOS Top Menu...
Страница 272: ...5 74 Installing the Operating System with Express Setup This page is intentionally left blank...
Страница 281: ...Installing and Using Utilities 6 9 4 Click Parameter File Creator Parameter File Creator appears...
Страница 308: ...7 12 Maintenance This page is intentionally left blank...
Страница 349: ...Troubleshooting 8 41 When you use a local console When you use a remote console 6 Each tool is selected and it starts...
Страница 408: ...9 54 Upgrading Your Server Screws...
Страница 415: ...Upgrading Your Server 9 61 When connecting to the optional RAID controller installed in the low profile slot...
Страница 416: ...9 62 Upgrading Your Server When connecting to the optional RAID controller installed in the full height slot...
Страница 446: ...9 92 Upgrading Your Server This page is intentionally left blank...
Страница 456: ......
Страница 458: ...C 2 IRQ This page is intentionally left blank...
Страница 490: ...D 32 Installing Windows Server 2008 4 Activate Windows The Windows activation is complete...
Страница 494: ......
Страница 544: ...G 2 Using a Client Computer with a CD Drive This page is intentionally left blank...
Страница 548: ...H 4 Product Configuration Record Table This page is intentionally left blank...
Страница 551: ......
Страница 552: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 46FB 00...