S-7300A
3. FUNCTION SETTINGS
12
Panel operation settings (300 to 399)
No. Setting range
Initial
value
Setting
units
Setting details
300
1
~
2
1
1
Movement when bobbin counter warning.
1: Sewing can continue by pressing the return key
2: Sewing is only possible when lower thread counter is reset after
replacing the bobbin.
301
0, 1
0
1
Program common function / program individual function settings
Needle up/ down
0: Program common function
1: Program individual function
302
0, 1
0
1
Program common function / program individual function settings
Thread trimming lock
0: Program common function
1: Program individual function
303
0, 1
0
1
Program common function / program individual function settings
Thread wiper
0: Program common function
1: Program individual function
304
0, 1
0
1
Program common function / program individual function settings
Correction sewing
0: Program common function
1: Program individual function
305
0, 1
1
1
Program common function / program individual function settings
AUTO/ auto thread trimming
0: Program common function
1: Program individual function
306
0, 1
0
1
Program common function / program individual function settings
Slow start
0: Program common function
1: Program individual function
307
0, 1
1
1
Program common function / program individual function settings
Special locus
0: Program common function
1: Program individual function
308
0, 1
1
1
Program common function / program individual function settings
Best PFM mode
0: Program common function
1: Program individual function
309
0, 1
1
1
Program common function / program individual function settings
X-over seam assist mode
0: Program common function
1: Program individual function
310
OFF,
30
~
300
(sec)
60
30
Automatic panel lock ON standby time
OFF: Automatic panel lock is disabled
30 - 300: Panel open time before panel lock turns on (sec)
* The standby time is only counted at the home screen.
If any other screen is displayed, the panel lock does not operate.
311
OFF, ON
ON
-
Panel auto lock when turn on power
OFF: Disabled
ON : Enabled
Содержание S-7300A
Страница 8: ...S 7300A vi Control box Oil tank Transformer box 100 V 400 V system only 0874D ...
Страница 9: ...S 7300A vii ...
Страница 107: ...S 7300A 6 ASSEMBLY 96 1094D 6 14 Stand 1 Stand L 2 Stands R 3 pcs ...
Страница 174: ...S 7300A 8 REPLACING PARTS 163 15 Install the top cover 1 16 Install the pulley cover 2 1029D 1030D ...