S-7300A
3. FUNCTION SETTINGS
19
Option input settings (900 to 999)
No. Setting range
Initial
value
Setting
units
Setting details
950
OFF,1
~
18
OFF
1
Function of option input 1
OFF: Disabled
1: Lower thread counter reset switch
(*) Option output 1 outputs lower thread counter warning signals.
2: End backtacking single cancel switch
(*) Option output 1 outputs end backtacking cancel signals.
3: Speed selection high-speed switch
(*) Option input 2 functions as a speed selection medium-speed switch.
(*) Option input 3 functions as a speed selection low-speed switch.
4: Single stitch correction sewing switch
5: Continuous correction sewing switch
6: Single stitch correction sewing switch at second pitch
7: Continuous correction sewing switch at second pitch
8: Reverse single stitch correction sewing switch
9: Reverse continuous correction sewing switch
10: Half stitch correction sewing switch
11: Feed quick reverse switch (when stopped)
12: Second Pitch
13: Second Pitch (change over)
14: Manual X-over seam sewing
15: Manual X-over seam sewing (change over)
16: Trimming switch
17: Foot lifter
18: Foot lifter (change over)
(*) The settings for correction sewing stitches (4 to 10) are enabled
when correction sewing is set to "ON".
951
OFF,1
~
2
OFF
1
Function of option input 2
(*) This is not displayed when MSW-950 is set to "3".
Option input 2 functions as a speed selection medium-speed switch.
OFF: Disabled
1: Operation prohibition input (operation by operating the treadle at Low,
etc. is prohibited)
2: Variable input for option output 3
(*) Only enabled when MSW-960 is set to "4"
952
OFF/1
OFF
1
Function of option input 3
(*) This is not displayed when MSW-950 is set to "3".
Option input 3 functions as a speed selection low-speed switch.
OFF: Disabled
1: Low-speed operation limit input (Limits the sewing speed using the
treadle to low speed at Low setting)
953
OFF/1
OFF
1
Function of option output 1
(*) This is not displayed when MSW-950 is set to "1" or "2".
Option output 1 outputs the following signals.
MSW-950 = "1": Lower thread counter warning signal
MSW-950 = "2": End backtacking cancel signal
OFF: Disabled
1: Error signal (Output ON when error is generated)
954
OFF,1
~
4
OFF
1
Function of option output 2
OFF: Disabled
1: Thread trimming solenoid signal (Output ON when thread trimming
solenoid is ON)
2: Quick reverse solenoid signal (Output ON when quick reverse solenoid
is ON)
3: Presser foot lifter solenoid signal (Output ON when presser foot lifter
solenoid is ON)
4: Automatic backtacking output signal (Output ON during automatic
backtacking)
955
300
~
5000
(sti/min)
1000
(sti/min)
100
Speed selected low speed SW (option input 3)
(*) Displayed when MSW-950 is set to "3".