S-7300A
10. ELECTRIC MECHANISM
167
10. ELECTRIC MECHANISM
DANGER
Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from the
wall outlet before opening the face plate of the control box. Touching areas where high voltages are
present will result in serious injury from electric shocks.
10-1. Precautions at the time of adjustment
Electric shock
Some large capacitors may have a high voltage remaining in them for up to 5 minutes after the power is turned off. To
prevent electric shock, wait at least 5 minutes after the power is turned off before doing the following:
• Opening and closing the contro
l box
• Replacing fuses
• Separating and joining connectors
• Measuring resistance
• Doing anything with a possibility of touching something inside the control box
Some adjustments require measuring the voltage while the power is turned on with the control box kept open.
In such a case, be careful not to touch any place other than that for the measurement. In addition, always keep in mind that a
high voltage remains for about 5 minutes after power is turned off.
Injury
When separating or rejoining connectors, and measuring something, be careful not to cut your fingers on metal parts such as
heat sinks and covers.
Pay attention to the following when opening the control box for maintenance.
Содержание S-7300A
Страница 8: ...S 7300A vi Control box Oil tank Transformer box 100 V 400 V system only 0874D ...
Страница 9: ...S 7300A vii ...
Страница 107: ...S 7300A 6 ASSEMBLY 96 1094D 6 14 Stand 1 Stand L 2 Stands R 3 pcs ...
Страница 174: ...S 7300A 8 REPLACING PARTS 163 15 Install the top cover 1 16 Install the pulley cover 2 1029D 1030D ...