Rev. 5.01
81
into contact with other grounded, conductive parts when connected to the
isolated animal input of the device. Such contact would bridge the animal's
isolation and cancel the protection provided by the isolated input. In
particular, there must be no contact of the neutral electrode and ground.
DEFIBRILLATION
—
Do not come into contact with animals during
defibrillation. Otherwise serious injury or death could result.
To avoid the risk of serious electrical burn, shock, or other injury during
defibrillation, all persons must keep clear of the bed and must not touch the
animal or any equipment connected to the animal.
After defibrillation, the screen display recovers within 10seconds if the
correct electrodes are used and applied in accordance with the
manufacturer’s
instructions.
Patient cables can be damaged when connected to an animal during
defibrillation. Check cables for functionality before using them again.
The peak of the synchronized defibrillator discharge should be delivered
within 60ms of the peak of the R wave. The signal at the ECG output on the
Veterinary Multiparameter monitor s is delayed by a maximum of 30ms.
If the ECG waveform on the screen is too unstable to synchronize with the
animal
’
s heart beat because of the following reason, remove the cause of an
alarm, message, or unstable ECG, and then use a stable ECG lead for
synchronization.
✓
ECG electrode is detached or broken. Lead wire is detached or broken.
✓
Lead wire moves. AC interference, EMG noise or noise from ESU is
superimposed.
✓
Connection cable is broken or has a short circuit. Connector has poor
contact.
INTERFACING OTHER EQUIPMENT
—
Devices may only be interconnected
Содержание BM Elite Series
Страница 21: ...Rev 5 01 21 Left side view Printer ...
Страница 25: ...Rev 5 01 25 Left side view Printer ...
Страница 29: ...Rev 5 01 29 Left side view Printer USB port ...
Страница 40: ...Rev 5 01 40 BM5Vet Elite BM7Vet Elite 1 2 3 4 1 2 3 4 ...
Страница 57: ...Rev 5 01 57 Display Mode Wave and numeric mode Numeric Mode ...
Страница 76: ...Rev 5 01 76 Pop up ST Window BM5 7Vet Elite BM3Vet Elite ...
Страница 84: ...Rev 5 01 84 Connector and Measurement cable ECG connector BM3Vet Elite BM5Vet Elite BM7Vet Elite ...
Страница 86: ...Rev 5 01 86 ECG Lead 5 Positions of 5 Lead Placement RL V LL LA RA 3 Positions of 3 Lead Placement LL LA RA ...
Страница 93: ...Rev 5 01 93 top waveform position 3 Select Pacemaker 4 SELECT PACEMAKER ON ...
Страница 102: ...Rev 5 01 102 Connector and Measurement Cable SpO2 connector BM5 7Vet Elite BM3Vet Elite ...
Страница 110: ...Rev 5 01 110 BM5Vet Elite BM7Vet Elite Cuff for USA only ...
Страница 160: ...Rev 5 01 160 EtCO2 malfunction Failure in battery recharge In case the battery will not charge in 6 hours or more ...
Страница 161: ...Rev 5 01 161 Power failure Print failure ...
Страница 162: ...Rev 5 01 162 Dual Gas Malfunction Data storage failure ...
Страница 163: ...Rev 5 01 163 Periodic Noises ...
Страница 215: ...Rev 5 01 215 BIONET CO LTD ...