172
FSN-1004 • User’s Guide • Rev 00
5. System Setup
Universal Input Setup
råáîÉêë~ä=fåéìí=pÉíìé
FSN-1004 system setup:
Step 7
In this procedure, you will perform a complete setup on all universal switcher inputs.
Ensure that your inputs are properly connected to the selected
UIC
before continuing.
Prerequisite
— Ensure that you are familiar with the following menus:
~
Input Menu
~
Connector Colors
~
Input Setup Menu
(Universal Inputs) — Chapter 4, “
,” page 123.
Universal Input Setup
— Use the following steps for basic universal input setup:
1.
In the
Menu Bar
, press
{System}
to access the
System Menu
.
2.
Press
{Input Setup}
to display the
Input Menu
.
3.
In the
Rear I/O View
, press the input connector on the
UIC
that you want to set
up. A yellow highlight is placed around all three input connectors, and in the
Input
Table
, the input is highlighted.
4.
Select the individual
UIC
connector — either the
BNC
,
HD-15
or
DVI
. A green
highlight indicates the selection.
5.
Press
{Input Name}
to name (or re-name) the selected input. When the pop-up
Keyboard
appears, enter the desired name and press
{Enter}
on the
Keyboard
.
6.
Press
{Error Reporting}
to turn error reporting on or off.
~
When
on
, if an input experiences an error, the connector turns red on the
rear I/O view, the input’s
Programmable Display
turns red, and the
“
Error
” button appears.
~
When
off
, the input’s
Programmable Display
remains green and the
red “
Error
” button does not appear. The connector remains red.
Capture and Timing
— Use the following steps to set up universal input capture and
timing parameters:
1.
Press
{Setup}
to display the
Input Setup Menu
for the selected universal input.
2.
Press
{Capture and Process}
to display the
Capture and Process Panel
.
3.
Press
{Auto Acquire}
to toggle the
Auto Acquire
mode
On
or
Off
as required.
~
When
Off
, you can set the resolution using the
{Input Format}
button.
~
When
On
, the system attempts to detect the resolution. When a match
is found, the format is applied and the
Format
field in the table is
7
Note
Remember that after a factory reset,
UIC
inputs are not
mapped to the GUI, but default names are assigned.
Note
The
{Error Reporting}
function works on a connector-by-
connector basis.
Содержание FSN-1004
Страница 1: ...r d cpkJNMMQ Manual 26 0702200 00 Revision 00...
Страница 12: ...12 FSN 1004 User s Guide Rev 00 Table of Contents...
Страница 24: ...24 FSN 1004 User s Guide Rev 00 NK f Application Questions...
Страница 182: ...182 FSN 1004 User s Guide Rev 00 5 System Setup Backing up the System...
Страница 213: ...FSN 1004 User s Guide Rev 00 213 7 Multiviewer Operations Multiviewer Memory...
Страница 214: ...214 FSN 1004 User s Guide Rev 00 7 Multiviewer Operations Multiviewer Memory...
Страница 220: ...220 FSN 1004 User s Guide Rev 00 8 Updating Software Updating FSN 1400 Software...
Страница 232: ...232 FSN 1004 User s Guide Rev 00 K p Output Format Tables...
Страница 246: ...246 FSN 1004 User s Guide Rev 00 Index...