190
FSN-1004 • User’s Guide • Rev 00
6. Operations
Working with Memory Registers
Multiviewer layouts, etc.). Using the System “Enables,” you can elect to include or
exclude certain system sub-functions.
When you include the
SYS
button in a recall function, the system
immediately
replaces all (or a portion of) the current System settings, based on your “enables.”
You can also modify the Enables, prior to pressing
ENTER
.
The table below summarizes the functions you can perform in each mode:
píçêáåÖ=jÉãçêó=oÉÖáëíÉêë
When you store a memory register, you take a “snapshot” of the switcher and the selected
modules. Once stored, you can
not
add data to that register — you can only overwrite it
with new data.
If you store
All Output Destinations
into register 100, you can not add
System data into that register. However, you could overwrite register 100
with new data.
Storing a memory register and setting Enables is an easy equation. This method stores
partial contents of the selected module(s).
•
STORE
,
[select register #]
,
[set Enables]
,
ENTER
The following topics are discussed in this section:
•
Store, Set Enables, Enter Custom Name
•
píçêÉI=pÉí=bå~ÄäÉëI=båíÉê=`ìëíçã=k~ãÉ
Use the following steps to store a memory register, set Enables, and enter a custom
register description:
1.
Set up the switcher in the exact configuration that you want stored.
2.
In the
GUI
, go to the
Memory
page, highlight a register number line in the table,
and select
STORE
.
3.
Open the
Enables Menu
by selecting the brown
Enables Button
at the bottom of
the screen. By default all Enables are "Off" for the System and Output modules.
4.
Choose the light blue
SYS
or
OUT
modules and turn ON the desired items to be
saved in this register. Remember that you can also use the
{All On}
and
{All Off}
functions.
Table 6-2.
Memory Menu modes and functions
Memory Menu
Mode
Name
Registers
Modules
Enables
Lock
Registers
Delete
Registers
View
Yes
View Only
View Only
Yes
Yes
Store
Yes
Modify
Modify
No
No
Recall
No
Modify
Modify
No
No
Note
In
Store Mode
, the description will not appear in the register
table until
ENTER
is pressed on the
Keypad
.
Содержание FSN-1004
Страница 1: ...r d cpkJNMMQ Manual 26 0702200 00 Revision 00...
Страница 12: ...12 FSN 1004 User s Guide Rev 00 Table of Contents...
Страница 24: ...24 FSN 1004 User s Guide Rev 00 NK f Application Questions...
Страница 182: ...182 FSN 1004 User s Guide Rev 00 5 System Setup Backing up the System...
Страница 213: ...FSN 1004 User s Guide Rev 00 213 7 Multiviewer Operations Multiviewer Memory...
Страница 214: ...214 FSN 1004 User s Guide Rev 00 7 Multiviewer Operations Multiviewer Memory...
Страница 220: ...220 FSN 1004 User s Guide Rev 00 8 Updating Software Updating FSN 1400 Software...
Страница 232: ...232 FSN 1004 User s Guide Rev 00 K p Output Format Tables...
Страница 246: ...246 FSN 1004 User s Guide Rev 00 Index...