- 46 -
Readers
Readers
ENT
Disarm timer-arm
YES
The functioning of the outdoor arming zones is programmed in this Menu for one key electronic board. By accessing
and exiting this menu, all pending armings will be disarmed.
Key functioning mode
•
Level mode:
when an arming input is balanced with its resistance, the control panel results disarmed; when the
resistance opens or short circuits, the control panel results armed.
Example of armings sum:
the arming from keypad and the closing of the arming input cause a sum of the armings,
with the result that, for the control panel to return in disarmed state, the arming clamp must be open and the keypad
disarmed.
ATTENTION:
when two armings are summed, the most important one in hierarchical order prevails.
•
Pulse mode:
the closing and subsequent re-opening of an arming input causes the arming of the control panel in
the relative modality; a new impulse will determine its disarming. With this setting, the control panel can be armed
and disarmed indifferently from keypad or from arming input, without bounds.
Disarms Timer-arm:
“With a “YES” the outdoor armings are enabled, for example “Electronic keys”, to disarm the
control panel previously armed from Timer. With a “NO”, to disarm the control panel wait for the automatic disarming
from Timer, or disarm from keypad with a User Code enabled to disarm with Timer active.
CAUTION: using this function voids compliance with EN50131
Arming zones
ENT
Working Mode
Pulse mode
Arming Zone
Reader on A500Plus
Command mode
Single
Keypad number:
selects the keypad A500Plus to be programmed
Modo comando:
• Single:
when the TOY is brought close to the reader, depending on programming of the associated user code, the
various options - ON, Scenario 1, Scenario 2, and Disarmed - are presented.
- If the keypad is associated to a single Partition, the options presented refer to the single Partition.
- If the keypad is associated to more than one Partition, and there is a “User-TOY” also associated to more than one
Partition, the options presented refer to the total of the Partitions in common between the keypad and the “User-TOY”.
• User code:
when the key is neared to the reader, one passes directly to the user menu.
- If the keypad is associated to a Partition, it will dire
ctly display the state of the Partition.
- If the keypad is associated to more partitions, it will display the possibility of choosing on which partition to work.
Press
(CLR)
to vary
Press
(
)
or
(
)
to move
Press
(ENT)
to confirm
Keypad number
1 (1 . . 8)
A500Plus
ENT
to following
page
from previus
page