DISTRIBUTION OF THE ZONES AND OPEN COLLECTORS (O.C.)
Central control unit terminals L1, L2, L3, L4 and all terminals L
XX
of the satellite models except models XSAT36, XSATPW and XSAT HP can be programmed
as zone inputs or as O.C. Outputs, or both at the same time. The central control unit also has 3 terminals O.C.1, O.C.2 and O.C.3 (“physical O.C.”) to which the
same number of “software O.C.” can be coupled
Programming the zones and Open Collectors is basically the same, except for a few small differences.
The zones available are divided up into two families, “
physical zones
” and “
software zones
”, and also the available O.C.s divide up into two families, “
physical
O.C.s
” and “
software O.C.s
”; the quantity available for both the zones and the O.C.s varies according to the central contol unit model:
•
CAPTURE 32
- max. 32 software zones out of max. 171 physical zones available; max. 32 software O.C.s out of 74 physical O.C.s available.
•
CAPTURE 16
- max. 16 software zones out of max. 99 physical zones available; max. 16 software O.C.s out of 42 physical O.C.s available.
•
CAPTURE 8
- max. 8 software zones out of max. 63 physical zones available; max. 8 software O.C.s out of 26 physical O.C.s available.
SOFTWARE ZONE/O.C. and PHYSICAL ZONE/O.C. ASSOCIATION
SOFTWARE ZONE/O.C.:
are the zones/O.C.s that can actually be programmed and for both they are a max. number of
32
for CAPTURE 32,
16
for CAPTURE 16
and
8
for CAPTURE 8. Only one “physical zone” can be associated with each “software zone” and one “physical O.C.” can be associated with each “software O.C.”.
PHYSICAL ZONE/O.C.:
are the inputs/outputs (terminals) on the various boards, whether they are central control unit, expansion, etc. boards. Corresponding
to each board are some “physical zones” and “physical O.C.s” that must be associated with the “software zones” and/or “software O.C.s” of the system. Each
“physical zone” can be associated with one or more “software zones”, and one or more “software O.C.s” can be associated with each “physical O.C.”.
The numbering given on the table is the default numbering of the central control unit.
- A “physical zone” is associated with each “software zone” in sequential order, starting from the central control unit terminals and going up to the last satellite
of the serial connection.
Example:
Central Control Unit Zones:
software zone 1 linked to terminal 1 of the central control unit base board - software zone 8 linked to terminal 8 of the central
control unit base board.
Satellite Zones:
software zone 9 linked to terminal 1 of the satellite base board with address 1 - zone 16 linked to terminal 8 of the satellite base board with
address 1 - software zone 17 linked to terminal 1 of the satellite base board with address 2 - zone 24 linked to terminal 8 of the satellite base board with address
2 - and so on
-
Only the first 3 “software O.C.s” are associated with 3 “physical O.C.s” that are, respectively, terminals OC1, OC2 and OC3 in the central control unit,
all the
others are configured as “not assigned”.
Example:
Central Control Unit O.C.s:
software O.C. 1 linked to terminal OC1 of the central control unit base board - software O.C. 3 linked to terminal OC3 of the central
control unit base board; software O.C. 4 set as “not assigned”
Satellite O.C.s:
no software O.C. is linked to the physical O.C.s in the various satellites.
If these associations should be changed for installation requirements, it is advisable to note them down on the table.
LEGEND:
Phisical zone
The physical zones are associated with the software zones, specifying if this input is found: on the central control unit/keyboard/satellite - on the base board/expan-
sion board and the number
.
CON =
CONTROL PANEL
PAD =
KEYPAD
SAT xx =
SATELLITE n. xx
BA.C =
BASIC ELECTRONIC BOARD CLAMP
EX.C =
EXTENSION ELECTRONIC BOARD CLAMPS
SEN xx
= RADIO DETECTORS and SERIAL DETECTORS (HP)
Phisical Open Collector
The physical O.C.s are associated with the software O.C.s, specifying if this output is found: on the central control unit/keyboard/satellite - and the number.
CON =
CONTROL PANEL
PAD =
KEYPAD
SAT xx =
SATELLITE n. xx
BA.C =
BASIC ELECTRONIC BOARD CLAMP
M.OC
=
OPEN COLLECTOR CLAMP
Note:
the distribution shown below is merely indicative and can be varied during programming.
COMPARATIVE TABLES
CONTROL PANEL
[CON BA.C:xx S]
CLAMP
L1
L2
L3
L4
L5
L6
L7
L8
OC1
OC2
OC3
pre-associated
SOFTWARE ZONE
1
2
3
4
5
6
7
8
-
-
-
associated
SOFTWARE ZONE
....
....
....
....
....
....
....
....
-
-
-
pre-associated
SOFTWARE O.C.
....
....
....
....
-
-
-
-
1
2
3
associated
SOFTWARE O.C.
....
....
....
....
-
-
-
-
....
....
....
KEYPAD
[KEYPAD 01..08]
KEYPAD
1
2
3
4
5
6
7
8
L1
L2
L1
L2
L1
L2
L1
L2
L1
L2
L1
L2
L1
L2
L1
L2
associated
SOFTWARE ZONE
.... .... .... .... .... .... .... .... .... .... .... .... .... .... .... ....
associated
SOFTWARE O.C.
.... .... .... .... .... .... .... .... .... .... .... .... .... .... .... ....