- 56 -
Account code:
in this menu, the telephone numbers are associated to the active sectors. Each telephone
number can be associated to one or more partitions.
Partition # :
select the Partition to program
Account code (Only showed
with the
DIGITAL
protocol
):
the digital communications must communicate
the Account Code (Client Code). Therefore, every telephone number, for every Partition, can have its own
Account Code.
•
In
SiA 1, SiA 2
and
SiA_HASi
the code is made of 6 digits;
•
In
FAST FORMAT
and
CONTACT ID
the code is made of 4 digits;;
N.B.:
To enter the Account code, use buttons 0 to 9 for the numbers and buttons UP (ON) and
DOWN (HO) for letters A, B, C, D, E, F.
Customizing vocal announcementl to introduce (Only showed
with the
VOCAL
protocol
):
introducing a value
different from zero (0) in the “WORD” programming menu, it is possible to activate the vocal announcement
of the plant introducing message.
Associate partition:
by setting “YES”, by setting “YES”, voice communication of the events relating to the
partition is enabled
Presentation speech:
introducing a value different from zero (0) will communicate the associated word (see
word table).
Partition speech:
introducing a value different from zero (0) will communicate the associated word (see word
table), linked to the associated partition.
N.B.: The
Partition speech
programming inserts the associated sound in the voice message of
the A500Plus keyboards if on/off voice communication is enabled
Says PARITION number
: choosing “YES” will communicate “Partition number” words.
Attempts number (of telephone number calls):
Communication is repeated for the number of times set. It
is clear that if the communication should have positive result, the attempts will not repeat. With regard to the
Vocal protocol, the control identifying the good result of the call is enabled through the “Listen Reply” option, if
the “Listen Reply” option should be disabled the dialler will perform as many calls as the set attempts.
If all call attempts should fail systematically for more times consecutively, a warning message will be displayed
in keypad:
“failed calls”
It is possible to interrupt the call to ones’ own telephone number by pressing key “4” on the telephone receiving
the message or it is possible to interrupt the full cycle of calls by pressing key “3” on the telephone receiving the
message, if the telephone number is associated to a User enabled for “interruption of the telephone communication”;
User:
It is possible to associate the telephone number to a certain User to give the number the user features.
This association enables the called user to have the enablings dictated by its profile of reference (ex: RTC -
Calls block - Number recognition).
The association of the telephone number to the user also allows, if enabled, to enter in RTC telephone on GSM
channel directly upon recognition of the incoming number without requesting the code.
The calls interruption or input in RTC commands following a call from the control panel, will be subordinate
Zones:
In this menu the alarm zones are associated to the telephone number.
In this way, the
individual alarm and/or zone tamper
can be communicated to the programmed telephone
number, if this is set at “YES” in the
menu: memorise alarm
. The zone reset is communicated if the
menu:
memorise reset
is set at “YES”.
ATTENTION:
it is necessary to associate the telephone number to one or more sectors to ensure that the
control panel can call in case of zones alarm. The control panel will communicate to the telephone number
the sector zones associated to the telephone number.
Technical messages:
the authorizations are automatic from the “EVENTS ASSOCIATION” submenu by the
phone numbers’ association and by the “SECTOR ASSOCIATION” submenu. From this very submenu, it is
possible to do it for the digital communication thanks to the association of the account code or vocally thanks
to the vocal message customization.
Events to dial:
The events to be sent to the telephone number are associated in this menu
Watch Dog:
Watch-Dog means a particular control function on the microprocessor; in cases of serious electrical disturbances
(lightning, sudden voltage changes, etc.) this circuit causes a “restart” of the system without loosing any recorded data.
Com. Tamper:
Communication of all events of Tamper type, to the associated telephone number; If associated
to a vocal protocol, the following message will be sent: “Tamper Alarm”
N.B.: By setting NO, the unit no longer complies with EN50131.
Mains fault:
Communication of the No network voltage to the associated number, after a delay programmable
in “Times Programming”.
Press
(CLR)
to vary
Press
(ENT)
to confirm
Press
(
)
or
(
)
to move
Press
(ESC)
to go back
Account code
ENT
Partition #
1 (1 .. 8)
Account code
0 0 0 0 0 0
Present. speech
0 (0 .. 415)
Partition speech
0 (0 .. 415)
Says part. number
NO
Attempts number
3 (1 .. 16)
User #
1 (1 .. 128)
Zones
YYYYYYYYYYYYYYYY
Telephone numbers
Events to dial
ENT
Watch-Dog
YES
Com. Tamper
YES
Mains fault
YES
Associate part.
NO
to following
page
from previus
page
Enable RTC func.
YES
Stop dialler
YES