- 42 -
Service Codes
Code #
Prog. when armed
YES
Communic. code
Access Password
000000
Installer Code 1:
this is one of two codes required for complete programming of the central control unit.
Code #:
The value of Installer Code 1 is set by default as 000000 (six zero digits).
Label:
It is possible to associate a description of up to 16 alphanumerical digits to each installer code.
Installer Code 2:
this is one of two codes required for complete programming of the central control unit.
Code #:
Installer Code 2 is disabled by default.
Label:
It is possible to associate a description of up to 16 alphanumerical digits to each installer code.
Prog. when armed:
by setting NO the access of the installer code is disabled if the control panel has at least one
Partition armed.
NOTA:
By entering the Installer Code any detection on the input zones and on the tamper proof zone is blocked;
all
pending calls are also cancelled
. If no key on the keypad is pressed for 2 minutes, programming is automatically
abandoned. It is possible to bring this time to 60 minutes, by accessing the
“Menu Block”
menu, enabling increase
of the system maintenance period.
Communication Code:
It is the code that, when entered using the keypad of the central control unit, can enable the
“USB connection” for interactive programming via USB connection (the “Reprogramming” step is for future uses);it is
not programmed by default; it is necessary to set a value from “Installer” menu to activate it.
N.B.:
use keys 0 to 9 to enter the password
Access Password:
It is an alphanumerical password composed of 6 digits; by default
000000.
This password allows the control panel to recognise the computer for reprogramming via a phone connection.
N.B.:
To enter the password, use keys 0 to 9 for the numbers and buttons UP (ON) and DOWN (HO) for letters A,B, C, D, E, F.
N.B.:
For the full enabling of the alignment it is necessary that the
Access Password
programmed in control panel,
be the same to those programmed in the computer for the selected client.
Service codes
ENT
User Codes
User codes
ENT
The programmable User Codes are in total 128 and enable access to all management functions of the control panel.
The values by default are:
Ex. : User Code 1:
000010;
User Code 63:
000630;
User Code 128:
001280
Code:
The user code can be composed of 4, 5 or 6 digits.
N.B.:
If the code is composed of 6 digits, it is not necessary to press
(ENT)
to confirm
.
Controlled partitions:
Every user code can be associated to one or more partitions.
If the sum modality is enabled, the User may decide to individually work on the various partitions for which it is enabled or,
by entering the “sum” modality using the 0 (zero) key, simultaneously carry out armings and disarmings on all partitions.
Arms in ON - command (ON):
“YES” enables the Code selected for the arming in the ON modality.
Disarmed - command (5):
“YES” enables the Code for the disarming of the control panel.
Macro A:
This comprises 64 possible multiple operations that can be associated with key A on the keypads (see
programming in “Macro”).
Macro B:
This comprises 64 possible multiple operations that can be associated with key B on the keypads (see
programming in “Macro”).
User Profile:
Associates the user code to one of n°8 profiles availabl
e in the menu
Master user:
If enabling the User as master, the code has priority on the keypads, it can therefore work on its partition
even from keypads not under its competence.
As well as this enabling it will also have other functions that are described in the “MASTER USER ENABLINGS” table;
certain functions are subject to enabling in the “User Profile”.
Code #
1 (1 ..128)
Code #
Partitions
Ynnnnnnn
Armed ON
Ynnnnnnn
Disarmed
Ynnnnnnn
User prof. #
1 (1 .. 8)
Macro A
1 (0 .. 64)
Macro B
2 (0 .. 64)
Label
Master user
YES
MASTER USER ENABLINGS
Function
Profile Enabling
Change User Codes (NO MASTER) of competence Partition
Change User Code: YES
Enable / Disable User Codes of competence Partition
Change User Code: YES
Change User Code (NO MASTER) label
Change User Code: YES
Vocal telephone numbers change of partitions of competence
Change tel. par.: YES
SIM Card expiry date variation
Change te. par.: YES
A500Plus keypad parameters variation
-
Installer cod 1
ENT
Code #
Deleted
Label
Installer cod 2
ENT
to following
page
from previus
page