- 63 -
App Manager
App Manager
ENT
Panel ID
ENT
Date / Time
Hours
15 (0 .. 23)
Minuts
30 (0 .. 59)
Day
10 (0 .. 31)
Month
5 (0 .. 12)
Year
13 (0 .. 99)
Date / Time
ENT
Date/Time Programming:
the current date and time appearing on the display keypad are set; for the analysis of the
events recorded in the events memory to be reliable, it is important that the date and time be correctly programmed.
Note: following a connection (USB/MODEM) with the Computer, the date and time automatically update with the
time on the PC.
Press
(CLR)
to vary
Enter the time
Press
(ENT)
to confirm
To access other entries press
(
)
or
(
)
Enter Minutes/Day/Month/Year
Press
(ENT)
to confirm
Press
(ESC)
to go back
APP Manager:
this menu is used to set the parameters for managing the dedicated App
“MY AVS ALARM”
Enable:
By setting “Yes”, connection of users with the
“MY AVS ALARM”
App is enabled.
“A”
and
“B”
identify the complementary
IP Addresses
to which the communications are sent and the relative port.
E.G.:
If the control panel does not dialogue via IP Addr
“A”
, it automatically reroutes communications to IP Addr
“B”
and remains connected until a dialogue block occurs with this IP Addr. Only in this case will communications
return to IP Addr “A”.
IP Addr A - dev.myavsalarm.com / IP Addr B - dev2.myavsalarm.com:
Parameter set by the service operator
(only to be changed if communicated by AVS Electronics).
Socket Port A - 27216 / Soket Port B - 272016:
Parameter set by the service operator (only to be changed if
communicated by AVS Electronics).
Panel ID:
the alphanumerical code that identifies the central control unit.
Press
(CLR)
to vary
Enter number to be set
To access other entries press
(
)
or
(
)
Press
(ENT)
to confirm
Dialler
Enable
NO
A
ENT
B
ENT
IP Addr
dev.myavsalarm.c
Socket Port
27216
IP Addr
dev2.myavsalarm.c
Socket Port
27216
Autotest
Autotest
ENT
I autotest Hour
0 (0 .. 23)
Autotest Interv.
0 (0 .. 255)
Autotest on arm
NO
The Autotest
is a dynamic test of the batteries of the control panel and of the intelligent additional supply units
(mod.
POWER1Q or POWER4Q);
it evaluates the discharging curve of the relative batteries and shows the result if negative.
It can be carried out at the programmed time and can also be intended as “supervision test of the system”, if rogrammed
to send a call to a tele-listening centre.
With the programming of the interval, it is established every how many hours the Self-test function will be carried out.
By entering the value 0 (zero), the Self-test will never be carried out.
Every time access is gained with the installer code to the programming menu, the self-test restarts from the time
and minutes programmed for the first self-test.
Example:
the self-test function is to be activated at
22:30 of every day
, both to evaluate the efficiency of the batteries
and to communicate the supervision of the same system.
Time 1st Autotest:
22
Min. 1st Autotest:
30
Autotest Interval:
24 (every 24 hours)
Autotest in Arming:
NO (if enabled, the self-test is carried out upon arming of any sector of the control panel if this is
at least 5 minutes from the previous).
Note:
The arming of the control panel is subject to the good outcome of the self-test procedure.
Press
(CLR)
to vary
Enter number to be set
To access other entries press
(
)
or
(
)
Press
(ENT)
to confirm
I Autotest Min.
0 (0 .. 59)
to following
page
from previus
page
Panel ID