- 53 -
Parameters
ENT
Alarms counter
Max 5 in 24h
Princ. sound tone
1 (1 . . 8)
Alt. sound tone
2 (1 . . 8)
Flash
Follows alm. st.
STC Command
Red Led = STC
Tamper enable
ENT
Antifoam
NO
Temperature
YES
Vibration
YES
LED Command
Green Led = LED
Reset Fire:
Activated when an enabled user performs a “Reset Fire Line” operation (pressing key 2 in the “User
Menu” ). If the time is set as Bistable, the output is activated for 15 seconds..
Timer:
it activates when the Timer reaches the pre-fixed day and time; it cannot be controlled by the user.
Autotest:
Activated when the central control unit performs the “Autotest” function.
If the time is set as Bistable, the output is activated for 3 seconds.
ON Arming:
by setting “YES”, it activates when the Partition is armed in ON
HOME Arming:
by setting “YES”, it activates when the Partition is armed in HOME
AREA Arming:
by setting “YES”, it activates when the Partition is armed in AREA
PERI Arming:
by setting “YES”, it activates when the Partition is armed in PERIMETRO
Disarmed:
by setting “YES”, it is activated when it is DISARMED, or when the PATROL TOUR TIME ELAPSES.
(using the patrol tour function; this signals that the patrol code is not entered within the programmed partition
(“patrol tour time”) reactivation time)
Normally active:
set to NO the output supplies a transistorized negative when activated. Set to YES, the output
usually supplies a transistorized negative which is lost when activated.
Blinking:
by setting “YES”, it flashes for the time it is active
OC audio enabled:
by setting “YES” the variation of the state of the O.C. output is vocally communicated
O.C. label:
it is possible to associate a description of 16 alphanumerical digits for every open collector;
Press
(CLR)
to vary
Writing keys::
(1)
abc1
(2)
def2
(3)
ghi3
(4)
jkl4
(5)
mno5
(6)
pqr6
(7)
stu7
(8)
vwx8
(9)
yz.
(0)
_’0
Press arrows
(
)
and
(
)
to position the cursor
Press
(ENT)
to confirm
Press
(ESC)
to go back
Parameters:
in this menu it is possible to personalise the work parameters of the Buzzer
Alarm counter: Max 5 in 24h:
the siren blocks the functioning of the Cone and the Flash in rest status after 5
alarms inwithin 24 hours and unblocks it after 24 hours from the first alarm.
Unlimited:
the siren does not perform any blocking
Pricipal sound tone:
it is possible to select one of 8 tones for the Principal Sound
Alternative sound tone:
it is possible to select one of 8 tones for the Alternative Sound
Flash:
Follows alarm state:
the Flash is restored at the rebalancing of the input that has generated the alarm
40 min./STC restore:
the Flash automatically deactivates after approximately 40 minutes or when the
STC input is rebalanced
STC restore
: the Flash is deactivated when the STC input is rebalanced
STC Command: Red Led = STC:
the RED LED is activated at the unbalancing of the STC input and is
deactivated at the rebalancing of the STC input
St. chg = 1 Beep
: a BEEP signals both the unbalancing and the rebalancing of the STC input
St.c. = 1 B.+Red L.
: the unbalancing of the STC input activates a BEEP and the RED LED, the
rebalancing of the STC input activates a BEEP and deactivates the RED LED
Beep only-No led
: RED LED and BEEP are not activated by the unbalancing of the STC input
Tamper enable:
In this step, the tampers to activate or otherwise the
T T output
and signalling to the central control
unit with serial connection are enabled.
Antifoam:
set at “Yes”, enables control of the Antifoam sensor of the Buzzer, when applicable
Temperature:
set at “Yes”, enables control of the Temperature sensor of the Buzzer
Vibration:
by setting “Yes”, control of the Vibration sensor of the Buzzer is enabled
LED Command:
Green Led = LED:
the unbalancing of the LED input activates the GREEN LED, the rebalancing of
the LED input deactivates the GREEN LED
Only alt. sound:
the unbalancing of the LED input activates the alarm with the Alternative Sound and
the Flash. The rebalancing deactivates the Sound while the Flash behaves based on its configuration.
Alt.sn. + Gr. Led:
simultaneously executes the actions of Value 1 and 2
Unbal. = memo STC:
the unbalancing of the LED input activates the visualisation of the STC input
status with the RED LEDs
Press
(CLR)
to vary
Press
(ENT)
to confirm
Press
(
)
or
(
)
to move
Press
(ESC)
to go back
Sirens
to following
page
from previus
page
Reset Fire
NO
Timer
NO
Autotest
NO
ON Arming
NO
HOME Arming
NO
AREA Arming
NO
Blinking
NO
OC audio en.
NO
O.C. Label
Normally active
NO
Disarmed
NO
PERI Arming
NO