- 52 -
Sirens
Blinking
NO
OC audio en.
NO
O.C. Label
LED Command
ENT
PERI Arming:
by setting “YES”, it activates when the Partition is armed in PERIMETRO
Disarmed:
by setting “Yes”. It is activated when it is DISARMED, or when the PATROL TOUR TIME ELAPSES.
(using the patrol tour function; it signals the failure to enter the patrol tour code within the programmed partition
(“patrol tour time”) reactivation time.
Normally active:
set to NO the output supplies a transistorized negative when activated. Set to YES, the output
usually supplies a transistorized negative which is lost when activated.
Blinking:
by setting “Yes”, it flashes for the time it is active.
OC audio enabled:
by setting “YES” the variation of the state of the O.C. output is vocally communicated
O.C. label:
it is possible to associate a description of 16 alphanumerical digits for every open collector;
Press
(CLR)
to vary
Writing keys::
(1)
abc1
(2)
def2
(3)
ghi3
(4)
jkl4
(5)
mno5
(6)
pqr6
(7)
stu7
(8)
vwx8
(9)
yz.
(0)
_’0
Press arrows
(
)
and
(
)
to position the cursor
Press
(ENT)
to confirm
Press
(ESC)
to go back
LED Command:
in this menu it is possible to personalise operation of the red LED or green LED and the sound
of the Buzzer according to the functions associated with this command
TIMES MANAGEMENT
Inactive:
the output does not activate;
Bistable:
the output follows the state of the associated function
MM:SS:
the output will activate for the set time (MM = Minutes / SS = Seconds)
HH:MM:
the output will activate for the set time (HH = Hours / MM = Minutes)
GG:HH:
the output will activate for the set time (GG = Days / HH = Hours)
“Times” Note:
the set values may be automatically rounded off after confirmation with
(ENT)
Partition:
Select one or more Partitions to which the LED command of the selected Buzzer is to be associated, and this is
automatically associated to all the zones of the Partitions set at Yes. For the events of a single zone or a set of targeted zones, it
is necessary to leave everything at NO and to associate the O.C. with the single zones of reference.
Alarm:
it activates with at least one of the associated zones in alarm state
Rebalancing:
it activates with the balancing of all the associated zones
Bypass:
it activates with the exclusion of at least one of the associated zones
Unbalancing:
it activates with the unbalancing of at least one of the associated zones
Tamper:
it activates with the tamper of at least one of the associated zones
Antimask:
it activates with the antimasking of at least one of the associated zones
Mains power failure:
with “YES”, it activates when the control panel or the supervised power units connected in
series are not powered, after a delay programmable in minutes. (see “Times”)
Power supply failure:
with “YES”, it activates when the voltage supplied by the power unit of the control panel or
by that of the supervised power units connected in series is higher than 16 V = or when it is lower than the voltage
generated by the battery or when the output voltage on the various board positives is lower than 10 V =
Low Battery:
with “YES”, it activates when the battery of the control panel or of one of the supervised power units
connected in series drops below 10.5 V and there is no charging voltage. It resets when voltage rises above 12.8 V =
Battery Unconnected:
with “YES”, it activates when the battery of the control panel or of one of the supervised
power units connected in series, drops below 3 V =
Battery fail:
with “YES”, it activates when the battery of the control panel or of one of the supervised power units
connected in series, drops below 9.5 V =
Telephone line fault:
with “YES”, it activates when the presence of the telephone line is no longer detected
Dialler on-line:
with “YES”, it activates when a telephone communication is in progress
OC on Ring:
by setting “YES”, it activates when the control panel receives a GSM call from a phone number
enabled to perform the function.
User:
it activates from RTC, from Keypad entering a user code with “User OC Enab.” enabled, from Timer or from
RING.
User access:
by setting “YES”, it activates when the associated User Code is entered (see User Profiles)
Fire:
it activates when there is a FIRE alarm coming from one of the satellites.
Press
(CLR)
to vary
Press
(ENT)
to confirm
Press
(
)
or
(
)
to move
Press
(ESC)
to go back
Normally active
NO
Disarmed
NO
PERI Arming
NO
to following
page
from previus
page
Partitions
YYYYYYYY
Alarm
NO
Rebalancing
NO
Bypass
NO
Unbalancing
NO
Tamper
NO
AntiMask
NO
Mains Fault
NO
Pwr supply fail
NO
Low Battery
NO
Batt. Unconnected
NO
Battery fail
NO
Tel. line fault
NO
Dialler on-line
NO
OC on Ring
NO
User
NO
User access
NO
Fire
NO
O.C. activ. time
Inactive