- 36 -
Chime
NO
Door
NO
Alarms audio en.
YES
Zones audio en.
YES
OR zone
NO
Zones
Test zones:
The zone to which the Test function has been enabled does not cause the activation of the programmed
alarm outputs nor the sending of calls, but only the memorising of the occurred alarm.
OR zone:
If several sectors share the zone, unbalancing triggers the alarm even if a single associated Partition is armed.
Chime:
Unbalancing the zone to which the Chime function is enabled activates the sound of the keypad buzzer; to
silence it, a User Code must be entered, enabled to disarm the system.
For example, it can be used to check the outputs opening, even emergency, with system disarmed.
Door:
Unbalancing the zone to which the Door function has been enabled activates the sound of the keypad buzzer;
everything is subject to the programming of the “DOOR Buzzer Time”. For example, it can be used to recall attention
on the synoptic controls or external visual signals.
Alarms audio enable:
the alarm of the input zones is communicated to the A500plus keypads enabled for
communication of the alarm.
Zones audio enable:
The unbalancing of the zones is communicated to the A500plus keypads enabled for
communication of the zones state.
Disable detection survival:
Set at “YES”, if wanting to deactivate the supervision control for the radio detector.
Disable detection fault:
Set at “YES”, if wanting to deactivate the fault control of the sensor connected in serial port
(HP series).
For every input line of the control panel it is possible to associate maximum 4 (four) state Open Collectors or alarm zone.
First O.C. 1:
Set the Open Collector to be activated for the unbalancing of the linea
Second/Third/Fourth O.C.
Set the Open Collector to be activated for the unbalancing of the line
Note:
the O.C. set must be programmed inside the menu as O.C. of
Cat. Partition or Cat. Zone
Press
(CLR)
to vary
Enter number of the O.C. to be activated
Press
(ENT)
to confirm
Press
(ESC)
to go back
Zone Label:
for every input zone it is possible to associate a description of 16 alphanumerical digits; this strip helps
the User in the understanding of the zones in which the system is subdivided.
Press
(CLR)
to vary
Writing keys:
(1)
abc1
(2)
def2
(3)
ghi3
(4)
jkl4
(5)
mno5
(6)
pqr6
(7)
stu7
(8)
vwx8
(9)
yz.
(0)
_’0
Press arrows
(
)
and
(
)
to position the cursor
Press
(ENT)
to confirm
Zone label
Test zones
NO
Dis. det. survival
NO
Dis. det. fault
NO
First O.C.
0 (0 ... 32)
Third O.C.
0 (0 ... 32)
Fourth O.C.
0 (0 ... 32)
Second O.C.
0 (0 ... 32)
to following
page
from previus
page