- 61 -
Zone / OC param.
ENT
Zone Nr. :
1 (1 .. 32)
Zones/Open Collector Parameters
FAST channel
3 (1 . . 8)
SIA Code
2 (1 . . 16)
In this Menu all codes identifying the type of event to be transmitted for every control panel software zone and for
every telephone protocol are defined.
It is also possible to customise the vocal alarm message of the single zones or state of the O.C. outputs using the
available vocabulary (see telephone table).
Zone number (1..32):
Select the zone to be customised and subsequently press
(ENT)
.
ZONES customisation:
FAST channel:
The values of the channels to be entered vary from 1 to 8.
Example:
by receiving this code, the Fast Format receiving control panel opens, in case of alarm, a channel
corresponding to the programmed code and closes it for resetting of the zone.
SIA coding (also valid for VOCAL protocol):
Depending on the code set, the message relating to the type of
zone varies, both in the vocal communications and in those addressed to the Digital receivers (SIA; SIAHAYES;
Contact ID).
(see “Example of telephone programming”)
The assignable
SIA
codes are:
Voice communication of zone codes
(Sia) WinRec 3.2 or above
Code 1
GENERAL
Code 9
IRRIGATION
Code 1 “ “
Code 9 SPRINKLER
Code 2
THEFT
Code 10
FLOODING
Code 2
THEFT
Code10
LIQUID LEVEL
Code 3
GAS
Code 11 TEMPERATURE
Code 3
GAS
Code11
COLD
Code 4
FIRE
Code 12 TAMPER
Code 4
FIRE
Code12 TAMPER
Code 5 TEMPERATURE
Code13
BURGLARY
Code 5 TEMPERATURE
Code13
SILENT
Code 6
DOCTOR
Code14
TECHNICAL
Code 6
DOCTOR
Code14
TECHNICAL
Code 7 PANIC
Code15
MASKING
Code 7 PANIC
Code15
MASKING
Code 8
EMERGENCY
Code 8
EMERGENCY
For every input zone, the control panel is able to recognise and, therefore, automatically send, four different states:
a) ALARM
b) RESET
c) LINE EXCLUDED
d) LINE RE-INCLUDED
Note:
By varying this coding the nature of the transmitted vocal messages is varied
Zones automatic communications
Says alarm/reset (communicates alarm/reset):
By setting “YES” the word ALARM or RESET is communicated
in vocal or included in the SMS
Says zone code (communicates the zone coding):
By setting “YES” the wording included in “SIA Coding” is
communicated in vocal or in the SMS
Says zone speech (communicates the telephone zone):
By setting “YES” the word ZONE is communicated in
vocal or included in the SMS
Says zone num. (communicates zone number):
By setting “YES” the ZONE NUMBER is communicated in vocal
or included in the SMS
Send string SMS (sends zone strip on SMS):
By setting “YES” the associated zone strip is included in the
sending of the SMS
Zones customised communications
By entering a value different from zero (0) in the programming steps “Vocal word 1 - 2 - 3 - 4”, it is possible to customise
the vocal alarm communication of the control panel with a maximum of 4 customised words. (See telephone table)
Vocal word 1:
By setting a numerical value different from “0”, the control panel will communicate the word associated
to the value (see telephone table)
Vocal word 2:
By setting a numerical value different from “0”, the control panel will communicate the word associated
to the value (see telephone table)
Vocal word 3:
By setting a numerical value different from “0”, the control panel will communicate the word associated
to the value (see telephone table)
Vocal word 4:
By setting a numerical value different from “0”, the control panel will communicate the word associated
to the value (see telephone table)
Press
(CLR)
to vary
Enter number to be set
Press
(ENT)
to confirm
FAST channels
ENT
Fast Channels
FAST arm/disarm
2 (1 . . 8)
FAST tamper
1 (1 . . 8)
FAST mains fault
4 (1 . . 8)
FAST fire
5 (1 . . 8)
Programming of all Channels to be activated for the signalling in Fast Format that do not relate to the zone events.
Below are all the Menus that allow entering the various parameters:
•
Fast Format
Channel for control panel
Armed/Disarmed
signal.
•
Fast Format
Channel for alarm signal of the
Tamper
dedicated zone.
•
Fast Format
Channel for alarm signal of the
Fire
dedicated zone.
•
Fast Format
Channel for microprocessor
Watch-Dog
signal.
•
Fast Format
Channel for signalling of
No mains fault
.
Press
(CLR)
to vary
Enter number to be set
Press
(ENT)
to confirm
FAST watch-dog
3 (1 . . 8)
Says alarm/rest.
YES
Says zone code
YES
Says zone speech
YES
Says zone number
YES
Vocal word 1
0 (0 .. 415)
Vocal word 2
0 (0 .. 415)
Vocal word 3
0 (0 .. 415)
Vocal word 4
0 (0 .. 415)
Send string SMS
YES
Dialler
to following
page
from previus