- 49 -
Events to dial
ENT
Com. Tamper
YES
Zone bypass
NO
ON Arming
YES
HOME Arming
NO
AREA Arming
NO
Mains fault
YES
Fire Zone
NO
Battery
YES
Watch-Dog
NO
Com. codes
NO
Com. Fire
NO
Autotest
NO
Com. Panic
NO
Com. Medic
NO
Sensor fault
NO
Interference
NO
Us/Key false
NO
GSM events
NO
PERI Arming
NO
Disarmed ON
YES
Disarmed HOME
NO
Disarmed AREA
NO
Disarmed PERI
NO
Antimask
NO
PSTN events
NO
A500Plus Audio
ENT
Partitions
YYYYYYYY
A500Plus Audio:
this menu is used to select the events that will be vocally communicated by the A500Plus keyboard.
Partitions (controlled Partitions):
(Y) associates the A500Plus audio to the Partition.
The audio can be enabled to work on one or more Partitions.
Events to dial:
In this menu the Audio events are associated to the A500Plus:
Watch Dog:
Communication of the Watch-Dog
Com. Tamper:
Communication of all events of Tamper type
Mancanza rete:
Communication of No network voltage after a delay programmable in “Times Programming”.
Battery:
Communication of the low level state of the battery
Autotest:
Communicates the self-test
FIRE Zone:
Communicates the fire protection alarm received from the Fire lines
Interference:
Communication of radio interference signal.
Sirens failures:
Communication of the faults relating to the Buzzers with serial connection
ON Arming:
Communication of the Arming in ON modality
HOMEArming:
Communication of the Arming in HOME modality
AREA Arming:
Communication of the Arming in AREA modality
PERI Arming:
Communication of the Arming in PERIMETER modality
Disarmed ON:
Communication of the disarming in ON modality
Disarmed HOME:
Communication of the disarming in HOME modality
Disarmed AREA:
Communication of the disarming in AREA modality
Disarmed PERI:
Communication of the disarming in PERIMETER modality.
Zone bypass:
Communication of an eventual zone exclusion
Sensor fault:
Communication of failure to receive Survival for the radio sensors,
Disqualification for the BMHP
barriers and Dirty lenses for the OUTSPIDER sensors.
Antimask:
Communication of reporting antimask wireless sensors enabled this feature.
Communicates codes:
Communication of the entering of an enabled code
Us. /key false (user/false keys):
Communication by a user or reading of a false TOY
Communicates Panic:
Communication of the panic message.
Communicates Medic:
Communication of the doctor message.
Communicates Fire:
Communication of the fire message.
PSTN Events:
Communicates the no telephone line
GSM Events:
Communicates the low SIM Card credit and, if set, also enables the call for GSM self-test
N.B.:
if ON/OFF voice communication is enabled, the Partition Sound programming inserts the associated audio
in the voice message of the A500Plus keyboards.
Press
(CLR)
to vary
Press
(
)
or
(
)
to move
Press
(ENT)
to confirm
A500Plus Audio
Sirens failures
NO
to following
page
from previus
page