- 48 -
Keypads
ENT
Keypads
Keypad number
1 (1 .. 8)
Partitions
YYYYYYYY
Buzzer on alarm
YES
Buzzer on exit
YES
Buzz. timer ann.
YES
Buzzer on entry
YES
Buzzer on chime
YES
Buzzer on door
YES
Beep of keys
YES
Enable Quick Arm
ENT
Keypad number:
selects the keypad to be programmed
Partitions (controlled Partitions):
with (Y) the keypad is associated to the Partition.
The keypad can be associated to work with one or more Partitions.
Buzzer:
For every keypad the functioning of the Buzzer can be individually enabled, in case of wanting to hear
the scanning of only the input, of output and of alarm time.
Example:
Keypad 1:
Alarm + Return
Keypad 2:
Alarm + Timer Warning
Buzzer on alarm:
if set at “Yes”, the Buzzer is enabled for the Zone, Tamper, Fire and Anti-mask alarms when
these are enabled in their relative configurations.
Buzzer on exit:
if set at “Yes”, during start-up, timed zones are activated, and the Buzzer is activated at a slow
cadence for the duration of the exit time.
Buzzer on entry:
if set at “Yes”, and if the activated timed zones are unbalanced, the Buzzer is activated at a fast
cadence for the duration of the entry time.
Buzzer on chime:
if set at “Yes”, and if at least one programmed zone like Chime is unbalanced, the Buzzer is
activated and emits a continuous sound.
Buzzer nn door:
if set at “Yes”, and if at least one programmed zone like Door is unbalanced, the Buzzer is
activated and emits a continuous sound.
Beep of keys:
Enables or not the beep of the keypad upon pressing of the keys;
- If set at NO, the Beep of the keys is always deactivated;
- If set at YES, the enabled user excludes and includes the Beep as it pleases.
Buzzer timer ann.:
It is the warning upon automatic inclusion of the timer, which can be enabled or not for every
keypad.
Enable QuickArm:
For each keypad it is possible to enable the Quick Arm function for ON, Macro key A and
Macro key B.
Armed ON:
Setting to “YES” enables the QuickArm option for ON
Utilizzando questa funzione decade la Conformità alle norme EN50131
Macro A:
Select a Macro number to activated in Quick Arm mode with key A.
Uilizzando questa funzione decade la Conformità alle norme EN50131
Macro B:
Select a Macro number to activated in Quick Arm mode with key B.
Utilizzando questa funzione decade la Conformità alle norme EN50131
ATTENTION:
Activation of the Macros with the Quick Arm function does not turn off the Partition.
A500Plus Audio:
the audio of the various events that are communicated can be enabled separately for each keypad.
A500Plus RTC:
“YES” enables the Keypad to the possibility of performing the RTC
Events Audio en.:
“YES” enables the Keypad to the possibility of activating the communications of the enabled
events
Zones audio en.:
“YES” enables the Keypad to the possibility of activating the communications of the
inputs
openings
OC Audio en.:
“YES” enables the Keypad to the possibility of activating the communications of the
activations
/ deactivations of OC outputs
Shift 1:
Defines in which of the 15 available shift, that can be programmed by the “Timer”, the A600 keyboard
audio is enabled. If 0 is set, the audio is always enabled.
Shift 1:
Defines in which of the 15 available shift, that can be programmed by the “Timer”, the A600 keyboard
audio is enabled. If 0 is set, the audio is always enabled.
Label:
it is possible to associate a description of 16 alphanumerical digits for every keypads;
Press
(CLR)
to vary
Writing keys::
(1)
abc1
(2)
def2
(3)
ghi3
(4)
jkl4
(5)
mno5
(6)
pqr6
(7)
stu7
(8)
vwx8
(9)
yz.
(0)
_’0
Press arrows
(
)
and
(
)
to position the cursor
Press
(
)
or
(
)
to move
Press
(ENT)
to confirm
Press
(ESC)
to go back
Armed ON
YES
Macro A
1 (0 . . 64)
Macro B
2 (0 . . 64)
A500Plus Audio
ENT
A500Plus RTC
YES
Events audio en.
YES
Zones audio en.
YES
OC audio en.
YES
Shift # 1
0 (0 . . 15)
Shift # 2
0 (0 . . 15)
Label
to following