Satellites
N.B.
Expansion cards mod.
C8 - XSAT36 - XSAT PW - XSATWS - XSATHP XGSM485
and must be connected to the
RS485
serial situated in the
same way as keyboards.
For more information, refer to the manual of its satellites.
X SAT WS:
In the event of problems with receiving the radio signal, the
XSATWS
expansion boards with an address from 1 to 8 can
be programmed to manage the same sensors in pairs (max. 4 pairs).
When programming, in the step “Installation > Match XSATWS”, it is possibile to create 4 satellite matches:
Setting the first to “yes” will match satellite 2 to satellite 1
XSATWS 1 with 2
NO
, setting the second to “yes” will match satellite 4 to
satellite 3 XSATWS 3 with 4
NO
and so on for the other two pairs. All you have to do is acquire the sensors in the first satellite of the pair
for them to be automatically managed also by the second. Any remote control handsets will have to be acquired in both satellites, as
though they are independent.
Just one radio siren can be matched to the central control unit, and this can be acquired and managed by a single radio satellite.
XSATHP:
The physical zone L1, L2, L3 and L4 inputs that manage only a type
2R
connection are in OR with the first four addressed
sensors. If, for example, there is both the sensor with address 1 and a sensor connected to terminal L1 of the satellite, the central control
unit would signal the corresponding zone in alarm status without specifying whether the actual sensor concerned is the one connected
to the terminal or is the serial sensor.
XGS485 and C8:
The physical inputs can be individually configured as zone input or as Open Collector output with reference to negative;
or both programmings simultaneously (the line input is managed directly by activation of the corresponding O.C.).
WARNING:
It is not possible to use the terminal as an OC output if programmed and physically cabled to control an external sensor and, similarly,
it is not possible to use the terminal as a zone input if programmed and physically connected to control a load with the OC output.
Please note that the tamper proof signals of the zones programmed with reading of the double balancing are managed
directly from the control panel.
INPUTS
OUTPUTS
OPTIONS
CONNECTIONS
HOUSINGS
CONSUMPTION
XSAT36
da V. 0.9 P4
n°10
to
n°18
with expandable mod.
XEXP8
n°1
dedicated to tamper proof
n°1
fire protection dedicated input
n°1
additional alarm relay
n°8
programmable o.c. outputs, to
interface with relay module
MR2 /
MR4 / MR8
With four wires
Single housing
CONTSAT W
~ 50 mA
XSATPW 3Q
XSATPW 5Q
da V. 0.9 P4
n°10
to
n°18
with expandable mod.
XEXP8
n°1
dedicated to tamper proof
n°1
fire protection dedicated input
n°1
additional alarm relay
n°8
programmable o.c. outputs, to
interface with relay module
MR2 /
MR4 / MR8
complete with
ower supply with
communications
a mains failure,
battery failure and
battery
With four wires
Single housing
CONTCAPTURE
~ 50 mA
XSATWS
da V. 0.9 P4
n° 32
radio sensors
n° 1
relay outputs C / NC pro-
grammable
With four wires
~ 45 mA
XSATHP
da V. 1.0p5
n° 32
sensors addressed
n° 4
in OR with the first four sensors
(only balance
2R
)
n°1
dedicated to tamper proof
n°1
Additional alarm relays
n°8
programmable o.c. outputs, to
interface with the relay module
MR2
/ MR4 / MR8
n ° 1
output (
FA
) is working properly
link for additional
power supply with
communications
a mains failure,
battery failure and
battery
With four wires
Single housing
CONTCAPTURE
~ 250 mA
XGSM485
da V. 1.2p0
n° 3
n°1
dedicated to tamper proof
n°3
programmable o.c. outputs, to
interface with the relay module
MR2
/ MR4 / MR8
you can program
X1, X2, X3 is as
zone inputs and
as outputs OC or
both at once
With four wires
Single housing
CONT SX
Single housing
CONT SX METAL
~ 320 mA
C8
n° 8
n°1
dedicated to tamper proof
n°8
programmable o.c. outputs, to
interface with the relay module
MR2
/ MR4 / MR8
you can schedu-
le L1 .... L8 both
as zone inputs or
as outputs OC or
both at once
With four wires
Single housing
CONT SAT W
Single housing
CONT SX
~ 38 mA