IP Office Installation
Installation Manual
Page 40
IP Office 2.1
40DHB0002USCL Issue 10c (11th May 2004)
Space requirements
Check that the planned location meets the following requirements.
•
Height :
•
A IP401 Compact Office module is 71mm (2.8 inches) high.
•
IP403, 406, 412 and all Expansion modules are 71mm(2.8 inches) high. Hence the total
height of a system is the number of modules multiplied by 71mm (2.8 inches).
•
Width :
•
A IP401 Compact Office module is 255mm (10 inches) wide.
•
IP403, 406, 412 and all Expansion modules are 445mm (17.5 inches) wide.
•
Depth :
•
A IP401 Compact Office module is 235mm (9.3 inches) deep.
•
IP403, 406, 412 and all Expansion modules are 245mm (9.7 inches) deep.
•
IP403, IP406, IP412 and Expansion modules can be mounted in 19" racks (see
Rack
Mounting Assembly Instructions
).
•
When modules are free standing (ideally mounted one upon another), allow a
minimum clearance of 50mm (20 inches) either side for cable trunking.
•
Check there is suitable lighting for installation, system programming and future
maintenance.
•
Check that there is sufficient working space for installation and future maintenance.
•
Ensure that likely activities near the system will not cause any problems, e.g. access
to and maintenance of any other equipment in the area.