IP Office Basic Edition - Quick Mode Installation
Page 28
15-601042 Issue 24i (20 December 2011)
IP Office 8.0
1.5.6 Lightning Protection/Out-of-Building Connections
The following are the only supported scenarios in which wired extensions and devices outside the main building can be
connected to the IP Office system. In these scenarios, additional protection, in the form of protective grounding and surge
protectors, must be fitted.
·
WARNING
The fitting of additional protection does not remove the risk of damage. It merely reduces the chances of damage.
·
Cables of different types, for example trunk lines, phone extensions, ground and power connections, should be kept
separate.
·
All cabling between buildings should be enclosed in grounded ducting. Ideally this ducting should be buried.
·
A Primary Protection Box must be provided at the point where the cables enter the building. This should be three
point protection (tip, ring and ground). Typically this would be gas tube protection provided by the local telephone
company. The ground wire must be thick enough to handle all the lines being affected by indirect strike at the same
time.
Connection Type
Protection Device Type
Requirement
Analog Phone Extensions
Phones External expansion
module (
POT
or
PHONE
)
ports only.
IP Office Barrier Box
Supports a single connection.
Maximum of 16 on any expansion
module.
·
Connection from the expansion module to the
phone must be via a surge protector at each end
and via the primary protection point in each
building.
·
The IP Office expansion module and control unit
and IROB devices must be connected to the
protective ground point in their building.
·
The between building connection must be via
earthed ducting, preferable underground. The cable
must not be exposed externally at any point.
DS Phone Extensions
External expansion module
DS
ports only.
ITWLinx towerMAX DS/2
Supports up to 4 connections.
(This device was previously
referred to as the Avaya 146E).
TCM Phone Extensions
None
Currently not supported.
Analog Trunks
ITWLinx towerMAX CO/4x4
Supports up to 4 two-wire lines.
(This device was previously
referred to as the Avaya 146C).
For installations in the Republic of South Africa, the
fitting of surge protection on analog trunks is a
requirement.
For other locations where the risk of lightning strikes
is felt to be high, additional protection of incoming
analog trunks is recommended.
External Output Switch
ITWLinx towerMAX SCL/8
(This device was previously
referred to as the Avaya 146G)
Connections from an IP Office Ext O/P port to an
external relay device must be via a surge protector.
The towerMAX range of devices are supplied by ITWLinx (
http://www.itwlinx.com
).
230
230
122
224
121
121
Содержание IP Ofice 8.0
Страница 1: ...15 601042 Issue 24i 20 December 2011 IP Office Basic Edition Quick Mode Installation IP Office 8 0 ...
Страница 6: ......
Страница 8: ......
Страница 38: ......
Страница 46: ......
Страница 80: ......
Страница 106: ......
Страница 132: ......
Страница 186: ...IP Office Basic Edition Quick Mode Installation Page 186 15 601042 Issue 24i 20 December 2011 IP Office 8 0 ...
Страница 238: ......
Страница 250: ......
Страница 254: ......
Страница 255: ...IP Office Basic Edition Quick Mode Installation Page 255 15 601042 Issue 24i 20 December 2011 IP Office 8 0 ...