IP Office Basic Edition - Quick Mode Installation
Page 72
15-601042 Issue 24i (20 December 2011)
IP Office 8.0
4.7 Connecting External Expansion Modules
Any external expansion modules should be connected to the control unit before
power is applied to the control unit. Ensure that modules are attached in the order
that matches the planned or pre-built configuration.
External expansion modules connect to the IP Office control unit using an
expansion interconnect cable. Each module is supplied with an expansion connect
cable and a
power supply unit
. An appropriate
locale specific power cord
for
the power supply unit must be ordered separately.
·
Each external expansion module is supplied with a blue 1 meter (3'3'') expansion interconnect cable. This
cable must be used when connecting to expansion ports on the rear of a control unit.
Installation Requirements
·
o
Installation space either on or under the existing IP Office control unit.
·
o
Switched power outlet socket.
·
o
Available EXPANSION port on the control unit.
·
o
Grounding Requirements
·
o
Functional Grounding
Connection of a
functional earth
is:
·
o
Recommend for all modules.
·
o
Connection of a functional ground is mandatory for Analog Trunk modules.
·
o
Protective Grounding
Connections of a protective ground via
surge protection equipment
is:
·
o
Mandatory for Analog trunk modules in the Republic of South Africa.
·
o
Mandatory for Digital Station and Phone modules connected to out of building extensions.
·
o
Mandatory for Digital Station V2 and Phone V2 modules.
Tools Required
·
o
Manager PC.
·
o
Tools for rack mounting
(optional).
Parts and Equipment Required
·
o
External Expansion Module.
Each module is supplied with a suitable external power supply unit and a 1m blue interconnect cable. 2m Yellow
interconnect cables are supplied with the IP500 4-Port Expansion card and should only be used with that card.
·
o
Power cord for the power supply unit
.
·
o
Rack mounting kit
(optional).
·
o
Wall mounting kit - IP500 external expansion modules only (optional).
·
o
Cable labeling tags.
22
23
27
28
70
23
29
Содержание IP Ofice 8.0
Страница 1: ...15 601042 Issue 24i 20 December 2011 IP Office Basic Edition Quick Mode Installation IP Office 8 0 ...
Страница 6: ......
Страница 8: ......
Страница 38: ......
Страница 46: ......
Страница 80: ......
Страница 106: ......
Страница 132: ......
Страница 186: ...IP Office Basic Edition Quick Mode Installation Page 186 15 601042 Issue 24i 20 December 2011 IP Office 8 0 ...
Страница 238: ......
Страница 250: ......
Страница 254: ......
Страница 255: ...IP Office Basic Edition Quick Mode Installation Page 255 15 601042 Issue 24i 20 December 2011 IP Office 8 0 ...