Parameter
Description
[AUPDCheckIfIniChanged ]
Determines whether the Automatic Update mechanism performs
CRC checking to determine if the
ini
file has changed prior to
processing.
[0]
= Do not check CRC. The
ini
file is loaded whenever the
server provides it. (default)
[1]
= Check CRC for the entire file. Any change, including line
order, causes the
ini
file to be re-processed.
[2]
= Check CRC for individual lines. Use this option when the
HTTP server scrambles the order of lines in the provided
ini
file.
[ResetNow]
Invokes an immediate device reset. This option can be used to
activate offline (i.e., not on-the-fly) parameters that are loaded using
the parameter IniFileUrl.
[0]
= The immediate restart mechanism is disabled (default).
[1]
= The device immediately resets after an
ini
file with this
parameter set to 1 is loaded.
Software/Configuration File URL Path for Automatic Update Parameters
[CmpFileURL]
Specifies the name of the
cmp
file and the path to the server (IP
address or FQDN) from where the device loads a new
cmp
file and
updates itself. The
cmp
file can be loaded using HTTP/HTTPS.
For example: http://192.168.0.1/filename
Notes:
For this parameter to take effect, a device reset is required.
When this parameter is configured, the device always loads the
cmp
file after it is reset.
The
cmp
file is validated before it's burned to flash. The
checksum of the
cmp
file is also compared to the previously
burnt checksum to avoid unnecessary resets.
The maximum length of the URL address is 255 characters.
[IniFileURL]
Specifies the name of the
ini
file and the path to the server (IP
address or FQDN) on which it is located. The
ini
file can be loaded
using HTTP/HTTPS.
For example:
http://192.168.0.1/filename
http://192.8.77.13/config<MAC>
https://<username>:<password>@<IP address>/<file name>
Notes:
For this parameter to take effect, a device reset is required.
When using HTTP or HTTPS, the date and time of the
ini
file are
validated. Only more recently dated
ini
files are loaded.
The optional string '<MAC>' is replaced with the device's MAC
address. Therefore, the device requests an
ini
file name that
contains its MAC address. This option allows the loading of
specific configurations for specific devices.
The maximum length of the URL address is 99 characters.
Содержание Mediant 800 MSBG
Страница 2: ......
Страница 366: ...SIP User s Manual 366 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Страница 372: ...SIP User s Manual 372 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Страница 390: ...SIP User s Manual 390 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Страница 404: ...SIP User s Manual 404 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Страница 616: ...SIP User s Manual 616 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Страница 636: ...SIP User s Manual 636 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Страница 652: ...SIP User s Manual 652 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Страница 886: ...SIP User s Manual 886 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Страница 890: ...User s Manual Ver 6 2 www audiocodes com ...