Metering Tone Parameters
The metering tone parameters are described in the table below.
Table
12-59: Metering Tone Parameters
Parameter
Description
Web: Generate Metering
Tones
EMS: Metering Mode
[PayPhoneMeteringMode]
Determines the method used to configure the metering tones that are
generated to the Tel side.
[0]
Disable = Metering tones aren't generated (default).
[1]
Internal Table = Metering tones are generated according to the
internal table configured by the parameter ChargeCode.
Notes:
This parameter is applicable only to FXS interfaces.
If you select 'Internal Table', you must configure the 'Charge Codes
Table' (see ''Configuring Charge Codes Table'' on page
Web: Analog Metering
Type
EMS: Metering Type
[MeteringType]
Determines the metering method for generating pulses (sinusoidal
metering burst frequency) by the FXS port.
[0]
12 KHz (default) = 12 kHz sinusoidal bursts
[1]
16 KHz = 16 kHz sinusoidal bursts
[2]
= Polarity Reversal pulses
Notes:
For this parameter to take effect, a device reset is required.
This parameter is applicable only to FXS interfaces.
Web: Analog TTX Voltage
Level
EMS: TTX Voltage Level
[AnalogTTXVoltageLevel
]
Determines the metering signal/pulse voltage level (TTX).
[0]
0V = 0 Vrms sinusoidal bursts
[1]
0.5V = 0.5 Vrms sinusoidal bursts (default)
[2]
1V = 1 Vrms sinusoidal bursts
Notes:
For this parameter to take effect, a device reset is required.
This parameter is applicable only to FXS interfaces.
Web: Charge Codes Table
EMS: Charge Codes
[ChargeCode]
This
ini
file table parameter configures metering tones (and their time
intervals) that the device's FXS interface generates to the Tel side.
The format of this parameter is as follows:
[ChargeCode]
FORMAT ChargeCode_Index = ChargeCode_EndTime1,
ChargeCode_PulseInterval1, ChargeCode_PulsesOnAnswer1,
ChargeCode_EndTime2, ChargeCode_PulseInterval2,
ChargeCode_PulsesOnAnswer2, ChargeCode_EndTime3,
ChargeCode_PulseInterval3, ChargeCode_PulsesOnAnswer3,
ChargeCode_EndTime4, ChargeCode_PulseInterval4,
ChargeCode_PulsesOnAnswer4;
[\ChargeCode]
Where,
EndTime = Period (1 - 4) end time.
Содержание Mediant 800 MSBG
Страница 2: ......
Страница 366: ...SIP User s Manual 366 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Страница 372: ...SIP User s Manual 372 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Страница 390: ...SIP User s Manual 390 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Страница 404: ...SIP User s Manual 404 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Страница 616: ...SIP User s Manual 616 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Страница 636: ...SIP User s Manual 636 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Страница 652: ...SIP User s Manual 652 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Страница 886: ...SIP User s Manual 886 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Страница 890: ...User s Manual Ver 6 2 www audiocodes com ...