Version 6.2
679
February 2011
SIP User's Manual
12. Configuration Parameters Reference
Parameter
Description
Web: RADIUS VSA Vendor ID
[RadiusVSAVendorID]
Defines the vendor ID that the device accepts when parsing a
RADIUS response packet.
The valid range is 0 to 0xFFFFFFFF. The default value is 5003.
Web: RADIUS VSA Access
Level Attribute
[RadiusVSAAccessAttribute]
Defines the code that indicates the access level attribute in the
Vendor Specific Attributes (VSA) section of the received RADIUS
packet.
The valid range is 0 to 255. The default value is 35.
12.6 SNMP Parameters
The SNMP parameters are described in the table below.
Table
12-23: SNMP Parameters
Parameter
Description
Web: Enable SNMP
[DisableSNMP]
Determines whether SNMP is enabled.
[0]
Enable = SNMP is enabled (default).
[1]
Disable = SNMP is disabled and no traps are sent.
[SNMPPort]
The device's local UDP port used for SNMP Get/Set
commands.
The range is 100 to 3999. The default port is 161.
Note:
For this parameter to take effect, a device reset is
required.
[SNMPTrustedMGR_x]
Defines up to five IP addresses of remote trusted SNMP
managers from which the SNMP agent accepts and processes
SNMP Get and Set requests.
Notes:
By default, the SNMP agent accepts SNMP Get and Set
requests from any IP address, as long as the correct
community string is used in the request. Security can be
enhanced by using Trusted Managers, which is an IP
address from which the SNMP agent accepts and
processes SNMP requests.
If no values are assigned to these parameters any
manager can access the device.
Trusted managers can work with all community strings.
[ChassisPhysicalAlias]
This object is an 'alias' name for the physical entity as
specified by a network manager, and provides a non-volatile
'handle' for the physical entity.
The valid range is a string of up to 255 characters.
[ChassisPhysicalAssetID]
This object is a user-assigned asset tracking identifier for the
device's chassis as specified by an EMS, and provides non-
volatile storage of this information.
The valid range is a string of up to 255 characters.
Содержание Mediant 800 MSBG
Страница 2: ......
Страница 366: ...SIP User s Manual 366 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Страница 372: ...SIP User s Manual 372 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Страница 390: ...SIP User s Manual 390 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Страница 404: ...SIP User s Manual 404 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Страница 616: ...SIP User s Manual 616 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Страница 636: ...SIP User s Manual 636 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Страница 652: ...SIP User s Manual 652 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Страница 886: ...SIP User s Manual 886 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Страница 890: ...User s Manual Ver 6 2 www audiocodes com ...