CHAPTER 51 Reporting Information to External Party
Mediant 4000 SBC | User's Manual
Field
Description
Latched T38
Port
[634]
Displays the latching of a new T.38 stream (new port). The field is an integer 0
to 0xFFFF.
Note:
■
The field is included in the default CDR.
■
The field is applicable only to "CALL_END" CDR Report Types.
■
The field is applicable only to SBC media and Gateway CDRs.
■
The default field title is "LatchedT38Port".
■
The maximum number of characters for Syslog tabular alignment is 15.
Leg ID
[310]
Displays the unique ID of the call leg within a specific call session. The field is
an integer.
A basic SBC call consists of two legs (incoming and outgoing) and thus, two
leg IDs are generated for the session, one for each leg.
A basic Gateway call consists of only one leg ID.
For each new call, the device assigns leg ID "1" to the first leg. The device then
increments the leg ID for subsequent legs according to the leg sequence in the
call session.
For example, the device generates leg ID "1" for the SBC incoming leg and leg
ID "2" for the SBC outgoing leg. If the call is transferred, the device generates
leg ID "3" for the leg belonging to the call transfer target. Another example is a
call forking session where the leg ID sequence may be as follows: incoming leg
is "1", outgoing leg to user's office phone is "2" and outgoing leg to the user's
mobile phone is "3". If the call is then transferred, the leg ID for the transfer leg
is "4".
Note:
■
The field is included in the default CDR.
■
The field is applicable to the "CALL_START", "CALL_CONNECT", and
"CALL_END" CDR Report Types.
■
The field is applicable only to SBC signaling and media, and Gateway
CDRs.
■
The default field title is "LegId".
■
The maximum number of characters for Syslog tabular alignment is 5.
Local Input
Octets
[606]
Displays the local input octets (bytes).
Note:
■
The field is optional and can be included in the CDR using the Gateway
CDR Format and SBC CDR Format tables.
■
The field is applicable only to "CALL_END" and "MEDIA_END" CDR
Report Types.
■
The field is applicable only to SBC media and Gateway CDRs.
■
The default field title is empty for RADIUS (ACCT_INPUT_OCTETS
standard ID 42).
■
The maximum number of characters for Syslog tabular alignment is 10.
Local Input
Packets
[604]
Displays the number of packets received by the device. The field is an integer
from 0 to 0XFFFFFFFF.
Note:
■
The field is included in the default CDR.
- 778 -
Содержание Mediant 4000 SBC
Страница 1: ...User s Manual AudioCodes Series of Session Border Controllers SBC Mediant 4000 SBC Version 7 2...
Страница 40: ...Part I Getting Started with Initial Connectivity...
Страница 48: ...Part II Management Tools...
Страница 113: ...Part III General System Settings...
Страница 118: ...Part IV General VoIP Configuration...
Страница 525: ...Part V Session Border Controller Application...
Страница 654: ...Part VI Cloud Resilience Package...
Страница 663: ...Part VII High Availability System...
Страница 685: ...Part VIII Maintenance...
Страница 759: ...Part IX Status Performance Monitoring and Reporting...
Страница 844: ...Part X Diagnostics...
Страница 888: ...Part XI Appendix...
Страница 1036: ...This page is intentionally left blank CHAPTER 62 Technical Specifications Mediant 4000 SBC User s Manual 1003...