CHAPTER 57 Testing SIP Signaling Calls
Mediant 4000 SBC | User's Manual
Parameter
Description
✔
Configure a Message Manipulation rule that adds
the NetAnn parameters, based on the tone that
you want played, to the INVITE message's
Request-URI.
✔
Configure a Number Manipulation rule that
changes the destination number to the Test Call
ID.
✔
Configure an IP Group to represent the device
itself (which will be the Test Call module) and
assign it the Message Manipulation rule and the
Number Manipulation rule.
✔
Configure an alternative routing rule in the IP-to-
IP Routing table that re-routes the call to the IP
Group presenting the Test Call module.
When the IP-to-IP call fails, the device uses the altern-
ative routing rule to re-route the call to the Test Call
module, which sends a SIP 183 response to the
caller, playing the specified tone.
'Play Tone Index'
play-tone-index
[Test_Call_PlayToneIndex]
Defines the tone that you want played from the installed
PRT file, to the called party when the call is answered.
The valid value is the index number (0-79) of the tone in
the PRT file. By default (-1), the device plays the tone
defined at index 22 "acDialTone2".
Note:
■
The parameter is applicable only if you configure the
'Play' parameter to
PRT
.
■
To play user-defined tones, you need to record your
tones and then install them on the device using a
loadable Prerecorded Tones (PRT) file, which is
created using AudioCodes DConvert utility. When
you create the PRT file, each recorded tone file must
be added to the PRT file with the tone type
"acUserDefineTone<Index>". For more information,
see
.
'Schedule Interval'
schedule-interval
[Test_Call_ScheduleInterval]
Defines the interval (in minutes) between automatic
outgoing test calls.
The valid value range is 0 to 100000. The default is 0 (i.e.,
scheduling is disabled).
Note:
The parameter is applicable only if you configure
'Call Party' to
Caller
.
Starting and Stopping Test Calls
The following procedure describes how to start, stop, and restart test calls.
➢
To start, stop, and restart a test call:
1.
In the Test Call Rules table, select the required test call entry.
2.
From the
Action
drop-down list, choose the required command:
- 847 -
Содержание Mediant 4000 SBC
Страница 1: ...User s Manual AudioCodes Series of Session Border Controllers SBC Mediant 4000 SBC Version 7 2...
Страница 40: ...Part I Getting Started with Initial Connectivity...
Страница 48: ...Part II Management Tools...
Страница 113: ...Part III General System Settings...
Страница 118: ...Part IV General VoIP Configuration...
Страница 525: ...Part V Session Border Controller Application...
Страница 654: ...Part VI Cloud Resilience Package...
Страница 663: ...Part VII High Availability System...
Страница 685: ...Part VIII Maintenance...
Страница 759: ...Part IX Status Performance Monitoring and Reporting...
Страница 844: ...Part X Diagnostics...
Страница 888: ...Part XI Appendix...
Страница 1036: ...This page is intentionally left blank CHAPTER 62 Technical Specifications Mediant 4000 SBC User s Manual 1003...