CHAPTER 19 Coders and Profiles
Mediant 4000 SBC | User's Manual
●
For supported audio coders, see
●
Some coders are license-based and are available only if included in the License
Key installed on your device. For more information, contact the sales
representative of your purchased device.
●
Only the packetization time of the first coder listed in the Coder Group is declared in
INVITE/200 OK SDP even if multiple coders are configured. The device always
uses the packetization time requested by the remote side for sending RTP
packets. If not specified, the packetization time is assigned the default value.
●
The value of some fields is hard-coded according to common standards (e.g.,
payload type of G.711 U-law is always 0).
●
The G.722 coder provides Packet Loss Concealment (PLC) capabilities, ensuring
higher voice quality.
●
Opus coder:
✔
For SBC calls: If one leg uses a narrowband coder (e.g., G.711) and the other
leg uses the Opus coder, the device maintains the narrowband coder flavor by
using the narrowband Opus coder. Alternatively, if one leg uses a wideband
coder (e.g., G.722) and the other leg uses the Opus coder, the device
maintains the wideband coder flavor by using the wideband Opus coder.
✔
Gateway calls always use the narrowband Opus coder.
●
For more information on V.152 and implementation of T.38 and VBD coders, see
Supporting V.152 Implementation
.
●
The G.729 coder refers to G.729A if silence suppression is disabled, or G.729AB if
silence suppression is enabled.
The following procedure describes how to configure the Coder Groups table through the Web
interface. You can also configure it through ini file [AudioCodersGroups] and [AudioCoders], or CLI
(
configure voip > coders-and-profiles audio-coders-groups
).
➢
To configure a Coder Group:
1.
Open the Coder Groups table (
Setup
menu >
Signaling & Media
tab >
Coders & Profiles
folder >
Coder Groups
).
2.
From the 'Coder Group Name' drop-down list, select the desired Coder Group index number
and name.
3.
Configure the Coder Group according to the parameters described in the table below.
4.
Click
Apply
, and then reset the device with a save-to-flash for your settings to take effect.
You can delete a Coder Group, as described in the following procedure.
- 385 -
Содержание Mediant 4000 SBC
Страница 1: ...User s Manual AudioCodes Series of Session Border Controllers SBC Mediant 4000 SBC Version 7 2...
Страница 40: ...Part I Getting Started with Initial Connectivity...
Страница 48: ...Part II Management Tools...
Страница 113: ...Part III General System Settings...
Страница 118: ...Part IV General VoIP Configuration...
Страница 525: ...Part V Session Border Controller Application...
Страница 654: ...Part VI Cloud Resilience Package...
Страница 663: ...Part VII High Availability System...
Страница 685: ...Part VIII Maintenance...
Страница 759: ...Part IX Status Performance Monitoring and Reporting...
Страница 844: ...Part X Diagnostics...
Страница 888: ...Part XI Appendix...
Страница 1036: ...This page is intentionally left blank CHAPTER 62 Technical Specifications Mediant 4000 SBC User s Manual 1003...