CHAPTER 17 Quality of Experience
Mediant 4000 SBC | User's Manual
Threshold
Crossing
Calculation
Threshold
based on
Example
Yellow to Red
(Major alarm)
The change occurs if the measured metric crosses the
configured Major threshold only (i.e., hysteresis is not used).
2
Red to Yellow
(Minor alarm)
The change occurs if the measured metric crosses the
configured Major threshold with hysteresis configured for the
Major threshold.
2.1 (i.e., 2 +
0.1)
Red to Green
(alarm
cleared)
The change occurs if the measured metric crosses the
configured Minor threshold with hysteresis configured for the
Minor threshold.
4.1 (i.e., 4 +
0.1)
Yellow to
Green (alarm
cleared)
The change occurs if the measured metric crosses the
configured Minor threshold with hysteresis configured for the
Minor threshold.
4.1 (i.e., 4 +
0.1)
Each time a voice metric threshold is crossed (i.e., color changes), the device can do the following
depending on configuration:
■
Report the change in the measured metrics to AudioCodes' OVOC. OVOC displays this call
quality status for the associated link (IP Group, Media Realm, or Remote Media Subnet). To
configure the OVOC's address, see
■
Depending on the crossed threshold type, you can configure the device to reject calls to the
destination IP Group or use an alternative IP Profile for the IP Group. For more information, see
Configuring Quality of Service Rules
■
Alternative routing based on measured metrics. If a call is rejected because of a crossed
threshold, the device generates a SIP 806 response. You can configure this SIP response
code as a reason for alternative routing (see
Configuring SIP Response Codes for Alternative
).
For your convenience, the device provides pre- configured Quality of Experience
Profiles. One of these pre- configured profiles is the default Quality of Experience
Profile, which is used if you do not configure a Quality of Experience Profile.
The following procedure describes how to configure Quality of Experience Profiles through the Web
interface. You can also configure it through other management platforms:
■
Quality of Experience Profile table:
ini
file [QoEProfile] or CLI (
configure voip > qoe
qoe-profile
)
■
Quality of Experience Color Rules table:
ini
file [QOEColorRules] or CLI (
configure
voip > qoe qoe-color-rules
)
➢
To configure a QoE Profile:
1.
Open the Quality of Experience Profile table (
Setup
menu >
Signaling & Media
tab >
Media
folder >
Quality of Experience
>
Quality of Experience Profile
).
2.
Click
New
; the following dialog box appears:
- 305 -
Содержание Mediant 4000 SBC
Страница 1: ...User s Manual AudioCodes Series of Session Border Controllers SBC Mediant 4000 SBC Version 7 2...
Страница 40: ...Part I Getting Started with Initial Connectivity...
Страница 48: ...Part II Management Tools...
Страница 113: ...Part III General System Settings...
Страница 118: ...Part IV General VoIP Configuration...
Страница 525: ...Part V Session Border Controller Application...
Страница 654: ...Part VI Cloud Resilience Package...
Страница 663: ...Part VII High Availability System...
Страница 685: ...Part VIII Maintenance...
Страница 759: ...Part IX Status Performance Monitoring and Reporting...
Страница 844: ...Part X Diagnostics...
Страница 888: ...Part XI Appendix...
Страница 1036: ...This page is intentionally left blank CHAPTER 62 Technical Specifications Mediant 4000 SBC User s Manual 1003...