CHAPTER 51 Reporting Information to External Party
Mediant 4000 SBC | User's Manual
Field
Description
■
The maximum number of characters for Syslog tabular alignment is 10.
Local
Packet Loss
[608]
Displays the number of packets lost of the entire stream. The field is an integer
from 0 to 0xFFFFFFFF (-1 if information is unavailable).
Note:
■
The field is included in the default CDR.
■
The field is applicable only to "CALL_END" and "MEDIA_END" CDR
Report Types.
■
The field is applicable only to SBC media and Gateway CDRs.
■
The default field title is "PackLoss" for Gateway Syslog and Local Storage,
and "LocalPackLoss" for SBC Syslog.
■
The maximum number of characters for Syslog tabular alignment is 10.
Local R
Factor
[625]
Displays the local R-factor conversation quality. The field is an integer from 0
to 120 (127 if information is unavailable).
Note:
■
The field is included in the default CDR.
■
The field is applicable only to "CALL_END" and "MEDIA_END" CDR
Report Types.
■
The field is applicable only to SBC media and Gateway CDRs.
■
The default field title is "LocalRFactor".
■
If the RTCP XR feature is unavailable (not licensed or disabled), this R-
factor VoIP metric is not provided. Instead, the device sends the CDR field
with the value 127, meaning that information is unavailable.
■
The maximum number of characters for Syslog tabular alignment is 12.
Local Round
Trip Delay
[609]
Displays the average round-trip delay time of the entire RTP stream. The field
is an integer from 0 to 10000 ms (-1 if information is unavailable).
Note:
■
The field is included in the default CDR.
■
The field is applicable only to "CALL_END" and "MEDIA_END" CDR
Report Types.
■
The field is applicable only to SBC media and Gateway CDRs.
■
The default field title is "RTPdelay".
■
The maximum number of characters for Syslog tabular alignment is 9.
Local RTP
IP
[620]
Displays the local RTP IP address.
Note:
■
The field is included in the default CDR.
■
The field is applicable only to "CALL_END", "CALL_CONNECT",
"MEDIA_END", "MEDIA_START", and "MEDIA_END" CDR Report
Types.
■
The field is applicable only to SBC media and Gateway CDRs.
■
The default field title is "LocalRtpIp".
■
The maximum number of characters for Syslog tabular alignment is 20.
Local RTP
Port
Displays the local RTP port. This field is an integer from 0 to 0xFFFF.
Note:
- 780 -
Содержание Mediant 4000 SBC
Страница 1: ...User s Manual AudioCodes Series of Session Border Controllers SBC Mediant 4000 SBC Version 7 2...
Страница 40: ...Part I Getting Started with Initial Connectivity...
Страница 48: ...Part II Management Tools...
Страница 113: ...Part III General System Settings...
Страница 118: ...Part IV General VoIP Configuration...
Страница 525: ...Part V Session Border Controller Application...
Страница 654: ...Part VI Cloud Resilience Package...
Страница 663: ...Part VII High Availability System...
Страница 685: ...Part VIII Maintenance...
Страница 759: ...Part IX Status Performance Monitoring and Reporting...
Страница 844: ...Part X Diagnostics...
Страница 888: ...Part XI Appendix...
Страница 1036: ...This page is intentionally left blank CHAPTER 62 Technical Specifications Mediant 4000 SBC User s Manual 1003...