The hardness of the water for steam generators feeding must not be higher than 12° F (French
degrees), 6,5 dH (German degrees) or 8,4° (Clark degrees). The use of water softeners with ionic
exchange resins temporarily reduces the water hardness but it brings down the PH (acidity). PH
values lower than 6,5 indicate that water is acid, consequently corrosive. The acidity can be
neutralized from polyphosphate by means of suitable measuring caps. We advise you to have
water analyzed by qualified technicians to avoid any damage to steam generators and to water
connections
TROUBLESHOOTING
PROBLEMS THAT MAY BE ENCOUNTERED
PROBLEM
POSSIBLE CAUSES
REMEDIES
Nothing lights up on the
control panel (2)
•
The magnetothermic protection
device is activated
•
Reset the magnetothermic switch
Motors do not start
•
The relevant magnetothermic
protection device is activated
•
Reset the magnetothermic switch
Fans and rack do not start
(2)
•
Door limit switch locked or faulty,
other causes.
•
Release or replace the door limit
switch
The rack does not stop in
the right position (2)
•
The cam on the shaft or the rack
limit switch has moved
•
Put them in the correct place and
tight the limit switch screws
Continuous leakage of
water from the steam
generators’ exhaust.
•
Dirty or faulty solenoid valve.
•
Clean or replace it;
Burner failure led on
•
Lack of gas oil
•
The photo-electric cell is dirty
•
The nozzle and ducts of the
burner are dirty
•
Check ducts and tanks
•
Clean photo-electric cell, nozzle
and ducts
•
Contact the burner technician
The burner or the heating
elements do not start.
•
The safety thermostat is activated
•
Faulty components in the control
circuit
.
•
Reset the safety thermostat
•
Replace the deteriorated parts
Little steam production
•
Low oven temperature
•
Little water (time-pressure)
•
Too many consecutive steam
injections
•
Formation of limescale on
elements and ducts of the spray
nozzles.
•
Increase the temperature
•
Increase pressure and steam
time.
•
Decrease the number of steam
injections
•
Clean ducts and remove limescale
The chamber lighting does
not come on (2).
•
The relevant magnetothermic
protection device is activated
•
Light bulb burnt out
•
Defective components or
connections
•
Reset the magnetothermic switch
•
Replace it (them) with the same
kind
•
Check the components and
replace them if needed
Some of the telltale lights
do not come on
•
Light bulb burnt out
•
Defective component part
•
Replace with component part
having the same characteristics
(2) See wiring diagram
Содержание Bakery Line J 106 C
Страница 10: ...RU Руководство по эксплуатации и техническому обслуживанию серии J стр 10 из 108 ...
Страница 11: ...RU Руководство по эксплуатации и техническому обслуживанию серии J стр 11 из 108 ...
Страница 22: ...RU Руководство по эксплуатации и техническому обслуживанию серии J стр 22 из 108 ...
Страница 40: ...RU Руководство по эксплуатации и техническому обслуживанию серии J стр 40 из 108 ПАНЕЛИ УПРАВЛЕНИЯ ...
Страница 54: ...RU Руководство по эксплуатации и техническому обслуживанию серии J стр 54 из 108 ...
Страница 63: ...EN Use and Maintenance manual J series ING Rev E Page 63 of 108 ...
Страница 64: ...EN Use and Maintenance manual J series ING Rev E Page 64 of 108 ...
Страница 75: ...EN Use and Maintenance manual J series ING Rev E Page 75 of 108 ...
Страница 94: ...EN Use and Maintenance manual J series ING Rev E Page 94 of 108 CONTROL PANELS ...
Страница 108: ...Equip Group 125080 г Москва Волоколамское шоссе д 2 7 495 234 00 33 http equipgroup ru http bakery apach it ...