Note: The steam generator is fitted on the right side wall of the baking chamber.
HEATING GROUP
Burner versions
•
Blown air burner with relevant gas supply ramp, in compliance with directive 2009/142 EC on gas (only
if supplied by Europa). As for power see TECHNICAL DATA.
•
Casing of the heat exchanger of gas-proof welded stainless steel sheet
•
Combustion chamber made of gas-proof welded stainless steel sheet
•
The combustion chamber front door is provided with a spy-hole to keep the flame under control.
combustion chamber
Electric versions
•
If the oven is electrical there is no burner and the combustion chamber is replaced by a batch of
armoured electric heating elements.
•
In an exhisting oven, it is not possible to replace the combustion chamber with electric heating
elements or vice versa
heating elements
Содержание Bakery Line J 106 C
Страница 10: ...RU Руководство по эксплуатации и техническому обслуживанию серии J стр 10 из 108 ...
Страница 11: ...RU Руководство по эксплуатации и техническому обслуживанию серии J стр 11 из 108 ...
Страница 22: ...RU Руководство по эксплуатации и техническому обслуживанию серии J стр 22 из 108 ...
Страница 40: ...RU Руководство по эксплуатации и техническому обслуживанию серии J стр 40 из 108 ПАНЕЛИ УПРАВЛЕНИЯ ...
Страница 54: ...RU Руководство по эксплуатации и техническому обслуживанию серии J стр 54 из 108 ...
Страница 63: ...EN Use and Maintenance manual J series ING Rev E Page 63 of 108 ...
Страница 64: ...EN Use and Maintenance manual J series ING Rev E Page 64 of 108 ...
Страница 75: ...EN Use and Maintenance manual J series ING Rev E Page 75 of 108 ...
Страница 94: ...EN Use and Maintenance manual J series ING Rev E Page 94 of 108 CONTROL PANELS ...
Страница 108: ...Equip Group 125080 г Москва Волоколамское шоссе д 2 7 495 234 00 33 http equipgroup ru http bakery apach it ...