P846/EN FD/D
Firmware Design
(FD) 9-8
MiCOM P846
FD
In the Opto Config. menu the nominal battery voltage can be selected for all opto inputs by
selecting one of the five standard ratings in the Global Nominal V settings. If Custom is
selected then each opto input can individually be set to a nominal voltage value.
Setting Range
Menu Text
Default Setting
Min. Max.
Step Size
OPTO CONFIG
Global Nominal V
24-27
24 - 27, 30 - 34, 48 - 54, 110 - 125,
220 - 250, Custom
Opto Input 1
24-27
24 - 27, 30 - 34, 48 - 54, 110 - 125,
220 - 250
Opto Input 2-32
24-27
24 - 27, 30 - 34, 48 - 54, 110 - 125,
220 - 250
Opto Filter Cntrl.
111111111111
Characteristic
Standard 60% - 80%
Standard 60% - 80%, 50% - 70%
Each opto input also has a pre-set filter of ½ cycle which renders the input immune to
induced noise on the wiring; although this method is secure it can be slow, particularly for
intertripping.
1.3.5
Power supply module (including output relays)
The power supply module contains two PCBs, one for the power supply unit itself and the
other for the output relays. The power supply board also contains the input and output
hardware for the rear communication port which provides an EIA(RS)485 communication
interface.
1.3.5.1 Power supply board (including EIA(RS)485 communication interface)
One of three different configurations of the power supply board can be fitted to the relay.
This will be specified at the time of order and depends on the nature of the supply voltage
that will be connected to the relay. The three options are shown in table 1 below:
Nominal dc Range
Nominal ac Range
24/54 V
DC only
48/125 V
30/100 Vrms
110/250 V
100/240 Vrms
Table 1:
Power supply options
The output from all versions of the power supply module are used to provide isolated power
supply rails to all of the other modules within the relay. Three voltage levels are used within
the relay, 5.1V for all of the digital circuits, ±16V for the analog electronics, e.g. on the input
board, and 22V for driving the output relay coils. All power supply voltages including the 0V
earth line are distributed around the relay via the 64-way ribbon cable. The power supply
board provides one further voltage level that is the field voltage of 48V. This is brought out
to terminals on the back of the relay so that it can be used to drive the optically isolated
digital inputs.
The two other functions provided by the power supply board are the EIA(RS)485
communications interface and the watchdog contacts for the relay. The EIA(RS)485
interface is used with the relay’s rear communication port to provide communication using
one of either Courier or DNP3.0 protocols. The EIA(RS)485 hardware supports half-duplex
communication and provides optical isolation of the serial data being transmitted and
received. All internal communication of data from the power supply board is conducted via
the output relay board that is connected to the parallel bus.
The watchdog facility provides two output relay contacts, one normally open and one
normally closed that are driven by the processor board. These are provided to give an
indication that the relay is in a healthy state.
Содержание MiCOM P846
Страница 2: ......
Страница 4: ......
Страница 5: ...Safety Section P846 EN SS H11 SS SAFETY SECTION...
Страница 6: ...P846 EN SS H11 Safety Section SS...
Страница 8: ...P846 EN SS H11 Safety Section SS 2 SS...
Страница 16: ...P846 EN IT D Introduction MiCOM P846 IT...
Страница 18: ...P846 EN IT D Introduction IT 1 2 MiCOM P846 IT...
Страница 26: ...P846 EN TD D Technical Data MiCOM P846 TD...
Страница 38: ...P846 EN GS D Getting Started MiCOM P846 GS...
Страница 58: ...P846 EN ST D Getting Started MiCOM P846 ST...
Страница 60: ...P846 EN ST D Settings ST 4 2 MiCOM P846 ST...
Страница 78: ...P846 EN OP D Operation MiCOM P846 OP...
Страница 104: ...P846 EN OP D Operation OP 5 26 MiCOM P846 OP...
Страница 106: ...P846 EN AP D Application Notes MiCOM P846 AP...
Страница 108: ...P846 EN AP D Application Notes AP 6 2 MiCOM P846 AP...
Страница 122: ...P846 EN AP D Application Notes AP 6 16 MiCOM P846 AP...
Страница 124: ...P846 EN PL D Programmable Logic MiCOM P846 PL...
Страница 126: ...P846 EN PL D Programmable Logic PL 7 2 MiCOM P846 PL...
Страница 144: ...P846 EN MR D Measurements and Recording MiCOM P846 MR...
Страница 146: ...P846 EN MR D Measurements and Recording MR 8 2 MiCOM P846 MR...
Страница 160: ...P846 EN FD D Firmware Design MiCOM P846 FD...
Страница 182: ...P846 EN CM D Commissioning MiCOM P846 CM...
Страница 228: ...P846 EN CM D Commissioning CM 10 46 MiCOM P846 CM...
Страница 230: ...P846 EN MT D Maintenance MiCOM P846 MT...
Страница 232: ...P846 EN MT D Maintenance MT 11 2 MiCOM P846 MT...
Страница 238: ...P846 EN TS D Troubleshooting MiCOM P846 TS...
Страница 240: ...P846 EN TS D Troubleshooting TS 12 2 MiCOM P846 TS...
Страница 252: ...P846 EN SC D SCADA Communications MiCOM P846 SC...
Страница 272: ...P846 EN SG D Symbols and Glossary MiCOM P846 SG...
Страница 280: ...P846 EN SG D Symbols and Glossary SG 14 8 MiCOM P846 SG...
Страница 282: ...P846 EN IN D Installation MiCOM P846 IN...
Страница 284: ...P846 EN IN D Installation IN 15 2 MiCOM P846 IN...
Страница 293: ...Installation P846 EN IN D MiCOM P846 IN 15 11 7 P846 CASE DIMENSIONS Figure 3 Case dimensions IN...
Страница 295: ...Installation P846 EN IN D MiCOM P846 IN 15 13 P1756ENa IN Figure 5 Model B with 32 output contacts and 24 digital inputs...
Страница 296: ...P846 EN IN D Installation IN 15 14 MiCOM P846 IN...
Страница 297: ......