Monitoring the Initialization Process
The line and controller cards perform an initialization process when you
power or reset the chassis. The initialization process takes approximately
three minutes to complete. The line cards do not begin to forward traffic
from their ports until the process is finished.
The process has two phases:
In the first phase, which takes approximately two minutes, the
controller card loads and initializes its AlliedWare Plus Operating
System and, if there are two controller cards in the chassis, sets its
active or standby state.
In the second phase, the Ethernet line cards receive their
management software from the active controller card, initialize the
software, and configure their parameter settings according to the
configurations provided by the active controller card. This phase
takes one minute, after which the line cards begin to forward traffic.
You may monitor the initialization process by viewing either the LEDs on
the cards or the messages on the Console port, as explained in the
following sections.
Using the LEDs
to Monitor the
Initialization
Process
To monitor the first phase of the initialization process in which the
controller card initializes its AlliedWare Plus Operating System and
establishes its active master or standby master state, examine the CFC
LED in the System Status LEDs on the card. The LED flashes green while
the card initializes its management software. When this phase is finished,
the card changes the LED to solid green if it is the active master or solid
amber if it is the standby master.
To monitor phase 2 in which the line cards initialize and configure their
management software, watch the SBx Linecard Status LEDs. There are
twelve LEDs (numbered 1 to 12), one for each slot. The LED for a slot
flashes green while the corresponding line card initializes its management
software and configures its settings in accordance with the settings from
the active controller card. The LED changes to solid green when the line
card completes the initialization process and begins forwarding traffic.
Using the Console
Port to Monitor
the Initialization
Process
Another way to monitor the initialization process of the chassis is to
connect a terminal or PC with a terminal emulator program to the Console
port on the controller card and watch the status messages. If the chassis
has two controller cards, you should use the Console port on the controller
card in slot 5. (The settings for the terminal or terminal emulator program
are found in “Using Local Management to Verify the Chassis” on
page 234.) Figure 151 on page 228 and Figure 152 on page 229 illustrate
the messages. The controller and line cards are fully initialized and
forwarding network traffic when the Console port displays the “awplus
Содержание AT-SB*81CFC960
Страница 20: ...20...
Страница 34: ...Chapter 1 Chassis and Power Supplies 34 Section I Hardware Overview...
Страница 94: ...Chapter 3 AT SBx81CFC960 Controller Fabric Card 94 Section I Hardware Overview...
Страница 96: ...96...
Страница 142: ...Chapter 6 Installing the Power Supplies 142 Section II Installing the Chassis...
Страница 166: ...Chapter 7 Installing the AT SBx81CFC960 Controller and Ethernet Line Cards 166 Section II Installing the Chassis...
Страница 230: ...Chapter 10 Powering On the Chassis 230 Section II Installing the Chassis...
Страница 254: ...Chapter 12 Troubleshooting 254 Section II Installing the Chassis...
Страница 298: ...Chapter 14 Upgrading the Controller Fabric Card 298 Section II Installing the Chassis...
Страница 300: ...300...
Страница 314: ...Chapter 15 VCStack Plus Overview 314 Section III Building a Stack with VCStack Plus...
Страница 356: ...Appendix A Technical Specifications 356...