34
USB device is not detected
This warning appears when USB storage device (Pen drive) is not detected for any reason.
Make sure that USB device works properly and that it is correctly connected to USB port. The pen drive must
have a FAT type format (nor FAT32 or other format).
USB drive initialization is not possible
This warning appears when the computer cannot access to the pen drive connected to USB port. Make sure
that the pen drive is connected. It is suggested to format USB device previously. The pen drive must have a
FAT type format (nor FAT32 or other format).
Create/open mapping file is not possible
Mapping file writing error
This warning is produced when access to
LOTEx.TXT
file from the SD card is not possible for any reason.
This can be due to the SD card is full or because the card is not working correctly. Check that SD card is into
the correct slot, and then turn the computer off and on. It is recommended to copy data from the SD card to a
PC, format the card and try again. The SD card must have a FAT type format (nor FAT32 or other format).
Open/access to file in destiny/origin drive is not possible
These warnings appear when you want to access to a file stored onto the drives and transfer files among them
but is not possible.
It is possible that the file or drive are damaged or not initialized. The SD card and pen drive must have a FAT
type format (nor FAT32 or other format).
It is recommended to turn the computer off and then on with the drive connected and try again
File error
Open/read/close/ file is not possible
Writing/Reading file error
Clear/copy file is not possible
These warnings appear when there is any problem in any drive file (SD or pen drive). It is recommended to save
into a PC all data contained by any of these storage drives, format them as FAT type (nor FAT32 or other
format) and try again.
Fertilizer/Seed rate not achieved
This message appears when the desired fertilizer o seed rate is not being applied by the agricultural implement.
This can be because of there is a CVT failure and this one cannot achieve the desired rate, or due to the
desired rate is out of the implement’s job range.
This message can appear for a few seconds when a rate change was produced or at the moment of starting to
work. Under these conditions no error is considered, but consider it if the message persists
It is recommended to check if the CVT works correctly under manual variable rate mode and make a significant
change in the rate. Then, if the CVT responds correctly, check that the rate value is within the job range.
Different Fertilizer/Seed rate
This message can appear in agricultural implements that work with more than one CVT to command the same
product. The computer is constantly checking that the CVTs apply the same rate for the same product. This
warning message will appear if one of the CVT is applying more or less rate.
This message can appear for a few seconds when the computer starts working, or when the land is not quite
smoothly making one command wheel works faster than the other. This should be considered as a problem if
the message persists. It is suggested to check that the all components associated to movement of the CVT’s