background image

 

34

USB device is not detected  

This warning appears when USB storage device (Pen drive) is not detected for any reason.   
Make sure that USB device works properly and that it is correctly connected to USB port. The pen drive must 
have a FAT type format (nor FAT32 or other format).   

USB drive initialization is not possible  

This  warning  appears  when  the  computer  cannot  access  to  the  pen  drive  connected to  USB  port.  Make  sure 
that  the  pen  drive  is  connected.  It  is  suggested to format  USB  device  previously.  The  pen  drive  must  have  a 
FAT type format (nor FAT32 or other format).   
 

Create/open mapping file is not possible 

 

Mapping file writing error  

This warning is produced when access to 

LOTEx.TXT

 file from the SD card is not possible for any reason.  

This can be due to the SD card is full or because the card is not working correctly. Check that SD card is into 
the correct slot, and then turn the computer off and on. It is recommended to copy data from the SD card to a 
PC, format the card and try again. The SD card must have a FAT type format (nor FAT32 or other format).   

Open/access to file in destiny/origin drive is not possible  

These warnings appear when you want to access to a file stored onto the drives and transfer files among them 
but is not possible.  
It is possible that the file or drive are damaged or not initialized. The SD card and pen drive must have a FAT 
type format (nor FAT32 or other format).   
It is recommended to turn the computer off and then on with the drive connected and try again 

File error  
Open/read/close/ file is not possible  
Writing/Reading file error  
Clear/copy file is not possible  

These warnings appear when there is any problem in any drive file (SD or pen drive). It is recommended to save 
into  a  PC  all  data  contained  by  any  of  these  storage  drives,  format  them  as  FAT  type  (nor  FAT32  or  other 
format) and try again.   

Fertilizer/Seed rate not achieved  

This message appears when the desired fertilizer o seed rate is not being applied by the agricultural implement. 
This  can  be  because  of  there  is  a  CVT  failure  and  this  one  cannot  achieve  the  desired  rate,  or  due  to  the 
desired rate is out of the implement’s job range.  
This message can appear for a few seconds when a rate change was produced or at the moment of starting to 
work. Under these conditions no error is considered, but consider it if the message persists 
It is recommended to check if the CVT works correctly under manual variable rate mode and make a significant 
change in the rate. Then, if the CVT responds correctly, check that the rate value is within the job range. 

Different Fertilizer/Seed rate  

This message can appear in agricultural implements that work with more than one CVT to command the same 
product.  The  computer  is  constantly  checking  that  the  CVTs  apply  the  same  rate  for  the  same  product. This 
warning message will appear if one of the CVT is applying more or less rate. 

This message can  appear for  a  few seconds when the computer  starts working, or when the land is  not  quite 
smoothly  making one  command wheel works  faster than  the  other. This  should  be considered as  a  problem  if 
the message persists.  It is  suggested to check  that the all components associated to movement  of the  CVT’s 

Содержание AGFusion

Страница 1: ......

Страница 2: ...s per meter that will be through in every row modifying the Density Seed value Page 20 The computer has a protection fuse of 5 A amperes in its power cable near to terminals that are connected to the...

Страница 3: ...onto the pen drive 19 8 Seed and fertilization monitoring 20 8 1 Seed density failure 20 8 1 2 How to change seed density and tolerance 21 8 1 3 How to Enable Disable Seed Density Monitoring 21 8 2 Se...

Страница 4: ...and fertilizer sensor status o Audible and displayed failures as follows Seed Density Failure incorrect value of the number of seeds planted per row Seed Failure seeds falling are not detected in pipe...

Страница 5: ...tributes ordered correctly The first attribute corresponds to Linear Fertilizer in Kg Ha the second one corresponds to Alongside Fertilizer in Kg Ha and the third one to seeds every 10 meters o It all...

Страница 6: ...in menu computer s data and configuration only for authorized users o Installer s security code to avoid activating any non desired function The critical functions are the ones which allow saving the...

Страница 7: ...hen Job Screen will appear as in Figure 1 Here different parts or areas with a particular type of information are presented Next each of these areas is described in more detail Figure 1 Job Screen 2 1...

Страница 8: ...e by the pipes Linear Fertilizer Rate kg ha On the right of the box heading Fert L it is displayed the desired value and on the box is displayed the real value applied Alongside Fertilizer Rate kg ha...

Страница 9: ...centage of available space onto the SD memory card where data is stored When mapping is disabled the symbol will be displayed Here there are two examples Selected plot 2 Mapping enabled Available spac...

Страница 10: ...ensity limits allowed according to the programmed Seed Tolerance Page 20 For instance if the computer is configured with Seed Density of 10 S m seeds per meter and Seed Tolerance of 20 then the horizo...

Страница 11: ...line will be displayed in red and an alarm will be activated details on Page 22 In order to get an optimum graphic viewing the Pipes tab will display 39 pipes simultaneously as maximum In case of more...

Страница 12: ...level Sensor OK auto adjust high level Sensor disabled page 25 Sensor disconnected page 33 Sensor with wire in short circuit page 33 1 Auto adjust level In some occasions a blanket of agrochemical in...

Страница 13: ...displays manual rate mode While in a job press the Rate key and select one of the four groups of rate preprogrammed previously In this case Rate1 setting is 110 Kg ha of Linear Fertilizer 95 Kg ha of...

Страница 14: ...ty configuration enabling disabling of densities fertilization section a particular sensor monitoring or do a sensor testing 6 DISPENSER This option groups the functions of VRA system selection of aut...

Страница 15: ...TOMATIC RATE SCREEN BACKLIGHT SETTING PROFILE SPEED LIMIT MAIN MENU INSTALLER SOPTIONS Details in Installation and Technical Assistance Guide JOB REGISTER MONITOR CLEAR PLOT CLEAR TOTALS MAPPING COPY...

Страница 16: ...uration Fine crop and coarse crop the setting profiles according to the installation moment will be saved In this way the user can recover them at any time just selecting the desired profile in Settin...

Страница 17: ...ber respectively If Job Mapping is activated the data is stored in a file named according to the number of the plot For example if plot number 2 is selected the text file where mapping will be saved i...

Страница 18: ...EEDS ROW 1 DENSITY ROW 2 DENSITY LAST ROW DENSITY LATITUDE first column Latitude of the point in decimal degrees LONGITUDE second column Longitude of the point in decimal degrees TIME third column Mom...

Страница 19: ...created A GPS receiver must be connected also because this one will provide positioning information on the plot 7 5 Job reports The computer will create a simple text file onto the SD card with job r...

Страница 20: ...presentation as follows In this example a Seed Density of 12 s m seeds per meter per row and Tolerance of 10 was programmed In this way the tolerable seed values will be within 10 8 and 13 2 S m 12 S...

Страница 21: ...seed density value To change this value select Seed Tolerance option from Monitor menu MENU MONITOR SEED TOLERANCE 8 1 3 How to Enable Disable Seed Density Monitoring If you want to disable seed densi...

Страница 22: ...e Figure 13 displays a linear fertilization failure in row 5 and alongside fertilization failure in rows 9 and 10 Figure 13 Linear fertilization failure in row 5 and alongside fertilization failure in...

Страница 23: ...Limit select that option in Main Menu MENU SPEED LIMIT 8 5 Shaft rotation failure Optional This failure will be activated when a monitored shaft stops rotation For example 8 6 Low level in hoppers Op...

Страница 24: ...ed is modified when the sensor is activated many times In order to test a rpm sensor check that the value displayed is not zero in the corresponding box A hopper sensor is activated when an object is...

Страница 25: ...s Next Node key to go to wiring configuration chart of the next node till localizes it Pressing Enable Yes No will modify its status Figure 15 displays the corresponding menu Figure 15 Enable or Disab...

Страница 26: ...steps to follow for fertilizer L Linear calibration 1 Enter to Rate Calibration option in DISPENSER menu Figure 106 MAIN MENU DISPENSER RATE CALIBRATION Figure 16 Rate Calibration Screen 2 Select the...

Страница 27: ...arrows or or down arrows to increase or to decrease the value respectively Then the computer will calculate the value that corresponds to 10 rounds exactly Figure 19 Figure 18 Fert L Rate Calibration...

Страница 28: ...manually so calibration repetition is not necessary This correction has to be done only when a not correct applied average is detected easily If the real amount of the applied product is over the one...

Страница 29: ...ys on the left hand side of the screen to and the arrow to the right Then pressing the arrows up and down the highlighted value will increase or decrease respectively Once all the rate values have bee...

Страница 30: ...of polygons that determines the zones or areas with similar attributes A data base file dbf contains the prescript rate values associates to each area Thus the first attribute corresponds to linear Fe...

Страница 31: ...being controlled with zero value for example 11 3 2 Automatic Variable Rate Mode Select Automatic Rate option in DISPENSER menu to initiate this mode Then the prescription selection will be displayed...

Страница 32: ...described in 2 2 section on Page 8 This screen also presents the loaded prescription s name map s orientation always the north on the top the current implement s position on the plot its geographical...

Страница 33: ...onnect them one by one till the error appears again In this way the node with problems will be indentified No connection with node Fert L Fert A Seed Monitor This message also indicates the node or no...

Страница 34: ...in File error Open read close file is not possible Writing Reading file error Clear copy file is not possible These warnings appear when there is any problem in any drive file SD or pen drive It is re...

Страница 35: ...lement s chassis The prescription should define less than 100 zones This message appears when trying to load a prescription map SHP that contains more than 10 areas on the same map It is suggested to...

Страница 36: ...e computer It is suggested to check that each node has been configured correctly No numerical DBF field The dbf file s field does not have a numerical format It must contain 3 numerical fields FERT L...

Страница 37: ...rface RS 232 Chassis Power wire and CAN bus Spearhead connection Node 1 Node 2 CAN bus Terminal AG FUSION Frontal view CAN bus Speed Sensor CVT 2 Sensor connectors CVT 1 CVT 3 Last CVT CAN bus AG FUSI...