23
8.3.1. Enable/Disable Monitoring for Linear or Alongside Fertilizer.
If you want to disable monitoring for a fertilization section momentarily, enter into Main Menu and select the
corresponding “Monitor” option. Follow the same procedure when you want to enable it again.
Enable/disable linear fertilizer:
MENU > MONITOR > LINEAR FERT. MONITORING (ENABLED/DISABLED)
Enable/disable alongside fertilizer:
MENU > MONITOR > ALONGSIDE FERT. MONITORING (ENABLED/DISABLED)
8.4. Speed limit exceeded
This warring appears when the programmed speed limit is exceeded.
If you wish modifying the programmed Speed Limit, select that option in Main Menu.
MENU > SPEED LIMIT >
/
8.5. Shaft rotation failure (Optional)
This failure will be activated when a monitored shaft stops rotation. For example:
8.6. Low level in hoppers (Optional))
This failure occurs when the monitored hopper is about to be completely empty. If the implement works under
this condition, an alarm will go off during 30 seconds, and the empty hopper icon will be displayed. (
).
Example:
8.7. Failure in RPM value (optional)
This failure occurs when the monitored shaft’s rounds are under or bellow the maximum or minimum revolution
limits, respectively.
Maximum or minimum rpm values for each monitored shaft are defined at the installation moment. Example:
Speed Limit Exceeded
Rotation failure in shaft 2
Low level in Hopper 4
RPM failure RPM. Shaft 3