TROUBLESHOOTING
214
Condor-UM-2011-21-R0-en-us-20210108
SPRAY PUMP (ALTEK P500)
Problem
Possible cause
Solution
The pump has no
suction power
Clogged suction filter
Clean / replace the filter ele-
ment
195
Suction filter cap not tightened
Tighten the filter cap
Loose fittings
Tighten the fittings
Leaking hoses
Replace the hoses
Leaking diaphragms
Replace the diaphragms
194
Worn inlet or outlet valve
Replace the valve
Damaged valve seat
Replace the cylinder head or
replace the pump
The pressure is too
low or is fluctuating
Clogged suction filter
Clean / replace the filter ele-
ment
195
Suction assembly pulls in false
air
Check for leaks
Clogged pressure filter
Clean / replace the filter ele-
ment
196
Loose fittings
Tighten the fittings
Leaking diaphragms
Replace the diaphragms
194
Pressure regulator not working
Repair the pressure regulator
(seals / diaphragm)
Worn inlet or outlet valve
Replace the valve
Damaged valve seat
Replace the cylinder head or
replace the pump
Driving speed signals not re-
ceived (or too few): defective
sensor in the wheel motor
Replace the sensor
Spray flowmeter signals are
duplicated
Replace the spray flowmeter
The pressure is too
high
Clogged pressure filter
Clean / replace the filter ele-
ment
196
Driving speed signals duplicat-
ed: defective sensor in the
wheel motor
Replace the sensor
Spray flowmeter does not turn
Disassemble and clean the
spray flowmeter
197
Spray flowmeter signals not
received
Replace the spray flowmeter
Содержание Condor C03
Страница 14: ...14 Condor UM 2011 21 R0 en us 20210108 ...
Страница 18: ...SAFETY 18 Condor UM 2011 21 R0 en us 20210108 ...
Страница 19: ...SAFETY Condor UM 2011 21 R0 en us 20210108 19 ...
Страница 54: ...START UP 54 Condor UM 2011 21 R0 en us 20210108 ...
Страница 79: ...OPERATION Condor UM 2011 21 R0 en us 20210108 79 No Description 27 28 Extra spray boom height UP DOWN Option ...
Страница 144: ...OPERATION 144 Condor UM 2011 21 R0 en us 20210108 ...
Страница 218: ...TROUBLESHOOTING 218 Condor UM 2011 21 R0 en us 20210108 ...
Страница 220: ...ENVIRONMENT 220 Condor UM 2011 21 R0 en us 20210108 ...
Страница 222: ...DISPOSAL PHASE 222 Condor UM 2011 21 R0 en us 20210108 ...
Страница 232: ...SPECIFICATIONS 232 Condor UM 2011 21 R0 en us 20210108 ...
Страница 233: ...APPENDICES Condor UM 2011 21 R0 en us 20210108 233 11 APPENDICES ...
Страница 248: ...APPENDICES 248 Condor UM 2011 21 R0 en us 20210108 ...