![Agilent Technologies 2000 X-Series Скачать руководство пользователя страница 69](http://html.mh-extra.com/html/agilent-technologies/2000-x-series/2000-x-series_user-manual_2868575069.webp)
Math Waveforms
4
Agilent InfiniiVision 2000 X-Series Oscilloscopes User's Guide
69
5
Press the
Source 1
softkey and select
g(t)
as the source. Note that
g(t)
is
only available when you select a transform function in the previous
step.
To adjust the math waveform scale and offset
1
Make sure the multiplexed scale and position knobs to the right of the
[Math]
key are selected for the math waveform.
If the arrow to the left of the
[Math]
key is not illuminated, press the
key.
2
Use the multiplexed scale and position knobs just to the right of the
[Math]
key to re- size and re- position the math waveform.
See Also
•
"Units for Math Waveforms"
on page 69
Units for Math Waveforms
Units for each input channel can be set to Volts or Amps using the
Units
softkey in the channel's Probe Menu. Units for math function waveforms
are:
N O T E
Math Scale and Offset are Set Automatically
Any time the currently displayed math function definition is changed, the function is
automatically scaled for optimum vertical scale and offset. If you manually set scale and
offset for a function, select a new function, then select the original function, the original
function will be automatically rescaled.
Math function
Units
add or subtract
V or A
multiply
V
2
, A
2
, or W (Volt-Amp)
FFT
dB* (decibels). See also
"FFT Units"
on
page 77.
Содержание 2000 X-Series
Страница 1: ...s1 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide ...
Страница 20: ...20 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide ...
Страница 44: ...44 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 1 Getting Started ...
Страница 58: ...58 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 2 Horizontal Controls ...
Страница 66: ...66 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 3 Vertical Controls ...
Страница 80: ...80 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 4 Math Waveforms ...
Страница 104: ...104 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 6 Digital Channels ...
Страница 110: ...110 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 7 Serial Decode ...
Страница 116: ...116 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 8 Display Settings ...
Страница 152: ...152 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 11 Trigger Mode Coupling ...
Страница 178: ...178 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 13 Cursors ...
Страница 214: ...214 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 16 Digital Voltmeter ...
Страница 226: ...226 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 17 Waveform Generator ...
Страница 238: ...238 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 18 Save Recall Setups Screens Data ...
Страница 244: ...244 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 19 Print Screens ...
Страница 280: ...280 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 21 Web Interface ...
Страница 334: ...334 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 24 I2C SPI Triggering and Serial Decode ...
Страница 352: ...352 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide Index ...