Waveform Generator
17
Agilent InfiniiVision 2000 X-Series Oscilloscopes User's Guide
217
For all waveform types, the output amplitude, into 50
Ω
, can be
adjusted from 10 mVpp to 2.5 Vpp (or from 20 mVpp to 5 Vpp into an
open- circuit load).
Pressing a signal parameter softkey can open a menu for selecting the
type of adjustment. For example, you can choose to enter amplitude
and offset values, or you can choose to enter high- level and low- level
values. Or, you can choose to enter frequency values or period values.
Keep pressing the softkey to select the type of adjustment. Turn the
Entry knob to adjust the value.
Waveform
Type
Characteristics
Sine
Use the Frequency/Frequency Fine/Period/Period Fine,
Amplitude/High-Level, and Offset/Low-Level softkeys to set the sine signal
parameters.
The frequency can be adjusted from 100 mHz to 20 MHz.
Square
Use the Frequency/Frequency Fine/Period/Period Fine,
Amplitude/High-Level, Offset/Low-Level, and Duty Cycle softkeys to set the
square wave signal parameters.
The frequency can be adjusted from 100 mHz to 10 MHz.
The duty cycle can be adjusted from 20% to 80%.
Ramp
Use the Frequency/Frequency Fine/Period/Period Fine,
Amplitude/High-Level, Offset/Low-Level, and Symmetry softkeys to set the
ramp signal parameters.
The frequency can be adjusted from 100 mHz to 100 kHz.
Symmetry represents the amount of time per cycle that the ramp waveform is
rising and can be adjusted from 0% to 100%.
Pulse
Use the Frequency/Frequency Fine/Period/Period Fine,
Amplitude/High-Level, Offset/Low-Level, and Width/Width Fine softkeys to
set the pulse signal parameters.
The frequency can be adjusted from 100 mHz to 10 MHz.
The pulse width can be adjusted from 20 ns to the period minus 20 ns.
DC
Use the Offset softkey to set the DC level.
Noise
Use the Amplitude/High-Level and Offset/Low-Level to set the noise signal
parameters.
Содержание 2000 X-Series
Страница 1: ...s1 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide ...
Страница 20: ...20 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide ...
Страница 44: ...44 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 1 Getting Started ...
Страница 58: ...58 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 2 Horizontal Controls ...
Страница 66: ...66 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 3 Vertical Controls ...
Страница 80: ...80 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 4 Math Waveforms ...
Страница 104: ...104 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 6 Digital Channels ...
Страница 110: ...110 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 7 Serial Decode ...
Страница 116: ...116 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 8 Display Settings ...
Страница 152: ...152 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 11 Trigger Mode Coupling ...
Страница 178: ...178 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 13 Cursors ...
Страница 214: ...214 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 16 Digital Voltmeter ...
Страница 226: ...226 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 17 Waveform Generator ...
Страница 238: ...238 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 18 Save Recall Setups Screens Data ...
Страница 244: ...244 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 19 Print Screens ...
Страница 280: ...280 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 21 Web Interface ...
Страница 334: ...334 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 24 I2C SPI Triggering and Serial Decode ...
Страница 352: ...352 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide Index ...