I2C/SPI Triggering and Serial Decode
24
Agilent InfiniiVision 2000 X-Series Oscilloscopes User's Guide
319
5
If you have set the oscilloscope to trigger on an EEPROM Data Read
condition:
Press the
Data is
softkey to set the oscilloscope to trigger when data is
= (equal to),
≠
(not equal to), < (less than), or > (greater than) the data
value set in the
Data
softkey.
The oscilloscope will trigger on the clock edge for the Ack bit after the
trigger event is found. This data byte does not need to occur directly
after the control byte. The oscilloscope will trigger on any data byte
that meets the criteria defined by the
Data is
and
Data
softkeys during a
current address read or a random read or a sequential read cycle.
6
If you have set the oscilloscope to trigger on a 7- bit address read or
write frame condition or a 10- bit write frame condition:
a
Press the
Address
softkey and turn the Entry knob to select the 7- bit
or 10- bit device address.
You can select from an address range of 0x00 to 0x7F (7- bit) or
0x3FF (10- bit) hexadecimal. When triggering on a read/write frame,
the oscilloscope will trigger after the start, address, read/write,
acknowledge, and data events occur.
If don't care is selected (0xXX or 0xXXX) for the address, the
address will be ignored. The trigger will always occur on the 17th
clock for 7- bit addressing or 26th clock for 10- bit addressing.
b
Press the
Data
value softkey and turn the Entry knob to select the
8- bit data pattern on which to trigger.
You can select a data value in the range of 0x00 to 0xFF
(hexadecimal). The oscilloscope will trigger after the start, address,
read/write, acknowledge, and data events occur.
SCL
SDA
Stop
Condition
Start or
Restart
Condition
Trigger point
26th clock edge
Address
1st byte
R/
Ack1
Ack
Address
2nd byte
Write
Ack2
Data
Содержание 2000 X-Series
Страница 1: ...s1 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide ...
Страница 20: ...20 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide ...
Страница 44: ...44 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 1 Getting Started ...
Страница 58: ...58 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 2 Horizontal Controls ...
Страница 66: ...66 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 3 Vertical Controls ...
Страница 80: ...80 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 4 Math Waveforms ...
Страница 104: ...104 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 6 Digital Channels ...
Страница 110: ...110 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 7 Serial Decode ...
Страница 116: ...116 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 8 Display Settings ...
Страница 152: ...152 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 11 Trigger Mode Coupling ...
Страница 178: ...178 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 13 Cursors ...
Страница 214: ...214 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 16 Digital Voltmeter ...
Страница 226: ...226 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 17 Waveform Generator ...
Страница 238: ...238 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 18 Save Recall Setups Screens Data ...
Страница 244: ...244 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 19 Print Screens ...
Страница 280: ...280 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 21 Web Interface ...
Страница 334: ...334 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 24 I2C SPI Triggering and Serial Decode ...
Страница 352: ...352 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide Index ...