Triggers
10
Agilent InfiniiVision 2000 X-Series Oscilloscopes User's Guide
125
The trigger level for a selected digital channel is set using the threshold
menu in the Digital Channel Menu. Press the
[Digital]
key on the front
panel, then press the
Thresholds
softkey to set the threshold level (TTL,
CMOS, ECL, or user defined) for the selected digital channel group. The
threshold value is displayed in the upper- right corner of the display.
The line trigger level is not adjustable. This trigger is synchronized with
the power line supplied to the oscilloscope.
Forcing a Trigger
The
[Force Trigger]
key causes a trigger (on anything) and displays the
acquisition.
This key is useful in the Normal trigger mode where acquisitions are made
only when the trigger condition is met. In this mode, if no triggers are
occurring (that is, the "Trig'd?" indicator is displayed), you can press
[Force
Trigger]
to force a trigger and see what the input signals look like.
In the Auto trigger mode, when the trigger condition is not met, triggers
are forced and the "Auto?" indicator is displayed.
Edge Trigger
The Edge trigger type identifies a trigger by looking for a specified edge
(slope) and voltage level on a waveform. You can define the trigger source
and slope in this menu. The trigger type, source, and level (if applicable)
are displayed in the upper- right corner of the display.
1
On the front panel, in the Trigger section, press the
[Trigger]
key.
2
In the Trigger Menu, press the
Trigger
softkey, and use the Entry knob
to select
Edge
.
3
Select the trigger source:
•
Analog channel,
1
to the number of channels
N O T E
You can also change the trigger level of all channels by pressing [Analyze] > Features and
then selecting Trigger Levels.
Содержание 2000 X-Series
Страница 1: ...s1 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide ...
Страница 20: ...20 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide ...
Страница 44: ...44 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 1 Getting Started ...
Страница 58: ...58 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 2 Horizontal Controls ...
Страница 66: ...66 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 3 Vertical Controls ...
Страница 80: ...80 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 4 Math Waveforms ...
Страница 104: ...104 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 6 Digital Channels ...
Страница 110: ...110 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 7 Serial Decode ...
Страница 116: ...116 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 8 Display Settings ...
Страница 152: ...152 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 11 Trigger Mode Coupling ...
Страница 178: ...178 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 13 Cursors ...
Страница 214: ...214 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 16 Digital Voltmeter ...
Страница 226: ...226 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 17 Waveform Generator ...
Страница 238: ...238 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 18 Save Recall Setups Screens Data ...
Страница 244: ...244 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 19 Print Screens ...
Страница 280: ...280 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 21 Web Interface ...
Страница 334: ...334 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 24 I2C SPI Triggering and Serial Decode ...
Страница 352: ...352 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide Index ...