© 2003, Adaptec, Inc.
153
152
Name
MLXEV_SYSDEV_EXPANDCAPACITY_ERROR
Description Expand capacity stopped with error.
Cause
Multiple physical disks failed.
Action
It may not be possible to recover from this error.
Contact your service representative.
Address
ctl: 0 logdrv: 15
Severity
2 (Error)
Source
ExPro InPro
153
Name
MLXEV_SYSDEV_BADBLOCK
Description Bad blocks found.
Cause
Bad sector was found on a physical device during consistency check/
rebuild/RAID expansion operation.
Action
Run a consistency check with the restore option.
Restore data from a backup.
Address
ctl: 0 logdrv: 15
Severity
2 (Error)
Source ExPro
InP_old
154
Name
MLXEV_SYSDEV_SIZECHANGED
Description Logical drive size changed.
Cause
A new configuration has been added.
RAID expansion has added extra capacity.
Action
None
Address
ctl: 0 logdrv: 15
Severity
4 (Information)
Source
InP_old
155
Name
MLXEV_SYSDEV_TYPECHANGED
Description Logical drive type changed.
Cause
A new configuration has been added.
RAID migration completed.
RAID expansion completed on RAID 1.
Action
None
Address
ctl: 0 logdrv: 15
Severity
4 (Information)
Source
ExPro InP_old
156
Name
MLXEV_SYSDEV_BADDATABLOCK
Description Bad data blocks found. Possible data loss.
Cause
Bad blocks were found on multiple physical disks in same zone.
Action
Restore data from a back up.
Address
ctl: 0 logdrv: 15
Severity
2 (Error)
Source
InPro
157
Name
MLXEV_SYSDEV_WR_LUN_MAP
Description System drive LUN mapping has been written to configuration.
Cause
–
Action
None
Address
ctl: 0
Severity
4 (Information)
Source
ExPro
158
Name
MLXEV_SYSDEV_DATAREAD_FROM_BLOCK_IN_BDT
Description Attempt to read data from block that is marked in Bad Data table.
Cause
Attempt to read from block that is already marked bad in Bad Data
table. Potential data loss.
Action
Restore data from a back up.
Address
ctl: 0 logdrv: 15
Severity
1 (Serious)
Source
InP_old
Table 2
RAID Controller Event Codes
Содержание MAN-00005-UG
Страница 11: ...12 Spheras Storage Director Installation and User Guide ...
Страница 28: ... 2003 Adaptec Inc 29 Figure 12 Installation Welcome ...
Страница 34: ... 2003 Adaptec Inc 35 Figure 19 Client installation complete ...
Страница 53: ...54 Spheras Storage Director Installation and User Guide ...
Страница 65: ...66 Spheras Storage Director Installation and User Guide ...
Страница 117: ...118 Spheras Storage Director Installation and User Guide Figure 87 Displaying Physical Drive Information text view ...
Страница 192: ... 2003 Adaptec Inc 193 Figure 105 Open Image File Dialog Box ...
Страница 199: ...200 Spheras Storage Director Installation and User Guide ...