184
Spheras Storage Director Installation and User Guide
897
Name
MLXEV_FATAL_BRKP
Description Internal controller firmware breakpoint.
Cause
Internal controller has encountered a firmware breakpoint.
Action
Power controller off and on.
Address
ctl: 0 version: 13.14 – 15 param: 0x23222120
Severity
1 (Serious)
Source
InPro
Paramtype
value
912
Name
MLXEV_I960_HW_ERROR
Description Internal controller i960 processor error.
Cause
Internal controller has encountered i960 processor specific error.
Action
Power controller off and on.
Address
ctl: 0 version: 13.14 – 15 param: 0x23222120
Severity
1 (Serious)
Source
InPro
Paramtype
value
Params
0x80008001 : name_HW_PATU_ERROR :
“Error in Primary Address translation unit”
0x80008002 : name_HW_SATU_ERROR :
“Error in Secondary Address Translation unit”
0x80008003 : name_HW_PBI_ERROR :
“Error in Primary side of PCI to PCI Bridge Unit”
0x80008004 : name_HW_SBI_ERROR :
“Error in Secondary side of PCI to PCI Bridge Unit”
0x80008005 : name_HW_ABI_ERROR :
“Error in Bus Interface Unit”
0x80008006 : name_HW_DMA0_ERROR :
“Error in DMA Unit , Ch0”
0x80008007 : name_HW_DMA1_ERROR :
“Error in DMA Unit , Ch1”
0x80008008 : name_HW_DMA2_ERROR :
“Error in DMA Unit, Ch2”
0x80008009 : name_HW_IntNMI_ERROR :
“Error caused by Software interrupt”
0x8000800A : name_HW_ExtNMI_ERROR :
“Error caused by External Source”
928
Name
MLXEV_SARM_HW_ERR
Description Internal controller Strong-ARM processor error.
Cause
Internal controller has encountered Strong-ARM processor specific
error.
Action
Power controller off and on.
Address
ctl: 0 version: 13.14 – 15 param: 0x23222120
Severity
1 (Serious)
Source
InPro
Paramtype
value
944
Name
MLXEV_SCSI_HW_ERR
Description Internal controller back end hardware error.
Cause
Timeout waiting for interrupt.
Timeout waiting for command completion.
Action
Power controller off and on.
Address
ctl: 0 version: 13.14 – 15
Severity
1 (Serious)
Source
InPro
Total events = 276
Table 2
RAID Controller Event Codes
Содержание MAN-00005-UG
Страница 11: ...12 Spheras Storage Director Installation and User Guide ...
Страница 28: ... 2003 Adaptec Inc 29 Figure 12 Installation Welcome ...
Страница 34: ... 2003 Adaptec Inc 35 Figure 19 Client installation complete ...
Страница 53: ...54 Spheras Storage Director Installation and User Guide ...
Страница 65: ...66 Spheras Storage Director Installation and User Guide ...
Страница 117: ...118 Spheras Storage Director Installation and User Guide Figure 87 Displaying Physical Drive Information text view ...
Страница 192: ... 2003 Adaptec Inc 193 Figure 105 Open Image File Dialog Box ...
Страница 199: ...200 Spheras Storage Director Installation and User Guide ...