Remember that some events are the result of other events; one event can cause a cascade of others if left unfixed. For
example, a problem with a hard drive causes a warning event, “Hard drive error found”, which could lead to a
consistency check error event, “Consistency check on logical drive error”, which could lead to a serious event, “A hard
disk has failed”, which could lead to a critical event, “A logical drive has failed.”
7.11.2
Repair an Array
Events that may cause an array to need repair:
•
Expand capacity stopped
•
Rebuild stopped
•
New device failure
•
Device failure
To repair an array, first see 6.2.2 Viewing Event Details on page 111. The event details tell you the event ID and give
you a description of the event that caused the array to need repair. Using this information, take measures to fix the
problem:
•
Check, all cable connections, to be sure none is disconnected or broken.
•
Check that all logical drives are present and functioning. If needed, see
7.11.3 Repair a Logical Drive on
page 197
.
•
Replace any parts that need to be replaced, such as a failed fan.
•
If expanding an array, make sure that the logical drives and physical drives can support the expansion. See 5.8
Expanding an Array on page 102 for more information.
7.11.3
Repair a Logical Drive
Events that may cause a logical drive to need repair:
•
The logical drive is critical
•
Logical drive failure
•
Logical drive initialization failure
•
Disk failure
•
Consistency check error or failure
•
A drive has been spun down
To repair a logical drive, first see 6.2.2 Viewing Event Details on page 111. The event details tell you the event ID and
give you a description of the event that caused the logical drive to need repair. Using this information, take measures to
fix the problem:
•
Check, all cable connections, to be sure none is disconnected or broken.
•
Check that all physical drives in the logical drive are present and functioning. Replace physical drives as needed.
•
Replace any parts that need to be replaced, such as a failed disk.
•
Check that the controller is installed and has power.
•
If a consistency check had an error or failed, try again. If this problem persists, replace the disk drive. Check the
errors other generated errors to identify the drive.
Содержание MAN-00005-UG
Страница 11: ...12 Spheras Storage Director Installation and User Guide ...
Страница 28: ... 2003 Adaptec Inc 29 Figure 12 Installation Welcome ...
Страница 34: ... 2003 Adaptec Inc 35 Figure 19 Client installation complete ...
Страница 53: ...54 Spheras Storage Director Installation and User Guide ...
Страница 65: ...66 Spheras Storage Director Installation and User Guide ...
Страница 117: ...118 Spheras Storage Director Installation and User Guide Figure 87 Displaying Physical Drive Information text view ...
Страница 192: ... 2003 Adaptec Inc 193 Figure 105 Open Image File Dialog Box ...
Страница 199: ...200 Spheras Storage Director Installation and User Guide ...