© 2003, Adaptec, Inc.
187
1 Select a logical drive from the navigation area or the content area.
2 Click
Logical->Check Consistency
from the menu bar.
Figure 99
Logical Drive Consistency Check
A Warning dialog box displays telling you that this process could result in data loss.
3 Select the
Automatically reconstruct data if errors are found
checkbox if desired.
CAUTION
:
Using this option can result in data loss.
4 Type your password.
5 Click
OK
to confirm the consistency check.
6 6.8 Monitoring Long Operation Tasks on page 128, to monitor the progress of your Consistency Check or cancel it.
7.3
Running a Manual Rebuild
In the event of a physical disk drive failure, a Rebuild is the process of regenerating and writing data to a replacement
disk drive. During a rebuild process, the system drive operates in an online critical and rebuilding, or degraded state.
The physical device is operating in an online rebuild state.
•
Arrays are rebuild candidates only if all of the logical drives use a redundant RAID level (1, 3, 5, 0+1).
•
The Automatic rebuild management controller parameter is disabled.
•
The Operational fault management controller parameter is enabled.
•
The replacement drive must have a capacity that is at least as large as the consumed capacity of the failed drive.
Use the following steps to perform a rebuild:
Содержание MAN-00005-UG
Страница 11: ...12 Spheras Storage Director Installation and User Guide ...
Страница 28: ... 2003 Adaptec Inc 29 Figure 12 Installation Welcome ...
Страница 34: ... 2003 Adaptec Inc 35 Figure 19 Client installation complete ...
Страница 53: ...54 Spheras Storage Director Installation and User Guide ...
Страница 65: ...66 Spheras Storage Director Installation and User Guide ...
Страница 117: ...118 Spheras Storage Director Installation and User Guide Figure 87 Displaying Physical Drive Information text view ...
Страница 192: ... 2003 Adaptec Inc 193 Figure 105 Open Image File Dialog Box ...
Страница 199: ...200 Spheras Storage Director Installation and User Guide ...