© 2003, Adaptec, Inc.
141
59
Name
MLXEV_PHYSDEV_MOVING_TO_OTHER_CHN
Description Physical disk is switching from one channel to the other channel.
Cause
Physical disk removed or channel failed
Action
Check Fibre Channel loop.
Replace physical disk if necessary.
Address
ctl: 0 chn: 13 tgt: 14
Severity
3 (Warning)
Source
ExPro
60
Name
MLXEV_PHYSDEV_OFFLINE_DEVICE_MADE_ONLINE
Description Temporary-Dead physical disk is automatically made online.
Cause
Temporary-Dead state caused because of transient errors
Action
Analyze event log to find out why the physical disk was marked
DEAD.
Address
ctl: 0 chn: 13 tgt: 14
Severity
2 (Error)
Source
InPro
61
Name
MLXEV_PHYSDEV_STANDBY_REBUILD_START
Description A standby rebuild has started.
Cause
A physical disk failed and a spare was available.
Action
None
Address
ctl: 0 chn: 13 tgt: 14
Severity
4 (Information)
Source
InPro
62
Name
MLXEV_PHYSDEV_HOT_SPARE_SMALLER
Description Hot spare replaced with a smaller capacity physical disk.
Cause
The new hot spare may have a smaller physical capacity than the
physical disk it replaced.
The controller coercion setting may have reduced the configurable size
of the new hot spare.
Action
None
Address
ctl: 0 chn: 13 tgt: 14
Severity
4 (Information)
Source
ExP_old
63
Name
MLXEV_PPILOT_LOGICAL_DISK_ONLINE
Description A storage access path has come online.
Cause
PATHpilot reported an access path has become available.
Storage previously unavailable has become available again.
Action
None
This indicates that storage access has been restored.
Address
PATHpilot:
Curr HBTL: 12, 13, 14, 15
Severity
4 (Information)
Source
PATHpilot
64
Name
MLXEV_PPILOT_LOGICAL_DISK_OFFLINE
Description A storage access path has been lost.
Cause
PATHpilot is unable to access certain storage on any path.
Storage previously available is now unavailable.
Action
Investigate possible causes (such as cabling, controller failure, HBA
failure).
Address
PATHpilot:
Last HBTL: 12, 13, 14, 15
Severity
1 (Serious)
Source
PATHpilot
Table 2
RAID Controller Event Codes
Содержание MAN-00005-UG
Страница 11: ...12 Spheras Storage Director Installation and User Guide ...
Страница 28: ... 2003 Adaptec Inc 29 Figure 12 Installation Welcome ...
Страница 34: ... 2003 Adaptec Inc 35 Figure 19 Client installation complete ...
Страница 53: ...54 Spheras Storage Director Installation and User Guide ...
Страница 65: ...66 Spheras Storage Director Installation and User Guide ...
Страница 117: ...118 Spheras Storage Director Installation and User Guide Figure 87 Displaying Physical Drive Information text view ...
Страница 192: ... 2003 Adaptec Inc 193 Figure 105 Open Image File Dialog Box ...
Страница 199: ...200 Spheras Storage Director Installation and User Guide ...