© 2003, Adaptec, Inc.
217
I want to emphasize performance _____ (see B.2 RAID Levels on page 214)
I have ____ channels on the array controller (usually 1, 2, or 3).
I plan to ___ /not to ____ use a Hot Spare disk.
I do ____ /do not _____ have a battery backup for the controller cache.
I do ____ /do not _____ have a UPS for the array.
B.4.2
Configuring for Maximum Capacity
The following table shows the relationship between the different RAID levels, effective capacities offered for X number
of drives of N capacity, and the computed capacities of five 2GB drives.
The greatest capacities (100%) are provided by RAID 0 and JBOD. Unfortunately, with these two solutions, there is no
fault-tolerance. RAID 5 gives the next best capacity, followed by RAID 1 or RAID 0+1.
B.4.3
Configuring for Maximum Availability
When considering optimizing for availability, it is important to understand some of the terminology concerning the
condition of array operation. These definitions are presented in the following table.
Maximum Capacity RAID Levels
RAID Level
Effective Capacity
Example (capacity in GB)
0
X*N
5*2=10
1
(X*N)/2
5*2/2=5
3
(X-1)*N
(5-1)*2=8
5
(X-1)*N
(5-1)*2=8
0+1
(X*N)/2
(5*2)/2=5
JBOD
X*N
5*2=10
Table 3
Maximum Capacity RAID Levels
Maximum Availability Array Conditions
Array
Condition
Meaning
Normal
The array is operating in a fault-tolerant mode and can sustain a drive failure
without potential data loss.
Critical
The array is functioning and all data is available, but the array cannot sustain
a drive failure without potential data loss.
Degraded
The array is functioning and all data is available, but the array cannot sustain
a drive failure without potential data loss. Additionally, a reconstruction or
rebuild operation is taking place, reducing the performance of the array. The
rebuild operation takes the array from a critical condition to a normal
condition.
Table 4
Maximum availability conditions
Содержание MAN-00005-UG
Страница 11: ...12 Spheras Storage Director Installation and User Guide ...
Страница 28: ... 2003 Adaptec Inc 29 Figure 12 Installation Welcome ...
Страница 34: ... 2003 Adaptec Inc 35 Figure 19 Client installation complete ...
Страница 53: ...54 Spheras Storage Director Installation and User Guide ...
Страница 65: ...66 Spheras Storage Director Installation and User Guide ...
Страница 117: ...118 Spheras Storage Director Installation and User Guide Figure 87 Displaying Physical Drive Information text view ...
Страница 192: ... 2003 Adaptec Inc 193 Figure 105 Open Image File Dialog Box ...
Страница 199: ...200 Spheras Storage Director Installation and User Guide ...