© 2003, Adaptec, Inc.
171
427
Name
MLXEV_CTLDEV_MIRROR_RACE_RECOVERY_FAILED
Description Mirror race recovery failed.
Cause
Some physical disks may have failed.
Action
Run consistency check and restore consistency.
Address
ctl: 0
Severity
1 (Serious)
Source
InPro
428
Name
MLXEV_CTLDEV_MIRROR_CRITICAL_DRIVE
Description Mirror race on critical logical drive.
Cause
Logical device is critical.
Action
Replace failed physical disk and rebuild.
Address
ctl: 0
Severity
1 (Serious)
Source
InPro
429
Name
MLXEV_CTLDEV_IN_CLUSTER
Description Controller connected to cluster.
Cause
One or more controllers detected during scan and entered nexus with
those controllers.
Action
None
Address
None
Severity
4 (Information)
Source
InPro
430
Name
MLXEV_CTLDEV_NOT_IN_CLUSTER
Description Controller disconnected from cluster.
Cause
All other controllers in cluster are inaccessible due to controller
powered off, controller failure, or cable failure.
Action
If this was an unexpected event, refer to service manual and correct the
failure.
Address
None
Severity
4 (Information)
Source
InPro
431
Name
MLXEV_SYSDEV_DATA_LOSS_IMPROPER_SHUTDOWN
Description Controller improperly shutdown. Data might have been lost.
Cause
User improperly shutdown the controller, resulting in inconsistent
logical drive and/or lost data.
Action
Run consistency check to verify logical drive consistency.
If needed, restore data from backup.
Address
ctl: 0 logdrv: 15
Severity
2 (Error)
Source
InPro
432
Name
MLXEV_CTLDEV_AUTOMATIC_FLASH_STARTED
Description Dual-active automatic flash of replacement controller.
Cause
Replacement controller is being flashed with survivor’s firmware.
Action
None
Address
ctl: 0
Severity
4 (Information)
Source
ExPro
433
Name
MLXEV_CTLDEV_NEGOTIATION_FAILED_JUMPERS
Description Dual-active negotiation failed jumpers.
Cause
Jumper settings do not match.
Action
Replace, adjust, or add components so that the controllers have the
same jumper settings.
Address
ctl: 0
Severity
2 (Error)
Source
ExPro
Table 2
RAID Controller Event Codes
Содержание MAN-00005-UG
Страница 11: ...12 Spheras Storage Director Installation and User Guide ...
Страница 28: ... 2003 Adaptec Inc 29 Figure 12 Installation Welcome ...
Страница 34: ... 2003 Adaptec Inc 35 Figure 19 Client installation complete ...
Страница 53: ...54 Spheras Storage Director Installation and User Guide ...
Страница 65: ...66 Spheras Storage Director Installation and User Guide ...
Страница 117: ...118 Spheras Storage Director Installation and User Guide Figure 87 Displaying Physical Drive Information text view ...
Страница 192: ... 2003 Adaptec Inc 193 Figure 105 Open Image File Dialog Box ...
Страница 199: ...200 Spheras Storage Director Installation and User Guide ...