186
Spheras Storage Director Installation and User Guide
1 Select a logical drive from the navigation area or the content area.
2 Click
Logical->Initialize
from the menu bar.
Figure 98
Logical Drive Initialization Warning
A Warning dialog box displays telling you that this process is data-destructive.
3 Type your password.
4 Click
OK
to confirm the initialization.
5 See 6.8 Monitoring Long Operation Tasks on page 128 to monitor the progress of your initialization or cancel it.
7.2
Running a Logical Drive Consistency Check
Run a consistency check on each of your fault tolerant logical drives on a regular schedule. Deciding on how often to
check your drives depends on the type of data. Run a consistency check more often if the cost of losing data is very
high, and run it less often if the cost of losing data is low. Running a consistency check lessens the exposure to possible
data loss situations. A consistency check scans the logical drive to determine whether consistency data has become
corrupted and needs to be restored.
Содержание MAN-00005-UG
Страница 11: ...12 Spheras Storage Director Installation and User Guide ...
Страница 28: ... 2003 Adaptec Inc 29 Figure 12 Installation Welcome ...
Страница 34: ... 2003 Adaptec Inc 35 Figure 19 Client installation complete ...
Страница 53: ...54 Spheras Storage Director Installation and User Guide ...
Страница 65: ...66 Spheras Storage Director Installation and User Guide ...
Страница 117: ...118 Spheras Storage Director Installation and User Guide Figure 87 Displaying Physical Drive Information text view ...
Страница 192: ... 2003 Adaptec Inc 193 Figure 105 Open Image File Dialog Box ...
Страница 199: ...200 Spheras Storage Director Installation and User Guide ...